Astigmatism-induced image degradation in a model eye with a monofocal intraocular lens

The influence of astigmatism on the image formed by a model eye with an intraocular lens (IOL) inserted is analysed. Toric (T-) and non-toric (N-) versions of the same monofocal spherical aberration-free IOL (20 D) were considered, for a range of uncorrected astigmatism from 0.0 to 2.0 D, and two pu...

Descripción completa

Detalles Bibliográficos
Autores: Azor Morón, Juan Antonio|||0000-0002-3093-3755, Vega Lerín, Fidel|||0000-0002-8594-0872, Armengol Cebrian, Jesús|||0000-0003-2880-752X, Millán Garcia-Varela, M. Sagrario|||0000-0001-6950-2373
Tipo de recurso: artículo
Fecha de publicación:2024
País:España
Institución:Universitat Politècnica de Catalunya (UPC)
Repositorio:UPCommons. Portal del coneixement obert de la UPC
Idioma:inglés
OAI Identifier:oai:upcommons.upc.edu:2117/407297
Acceso en línea:https://hdl.handle.net/2117/407297
https://dx.doi.org/10.7149/OPA.57.1.51168
Access Level:acceso abierto
Palabra clave:Astigmatism
Intraocular lenses
Intraocular lens
Adaptive optics
Modulation transfer function (MTF)
Optical image quality
Astigmatisme
Lents intraoculars
Àrees temàtiques de la UPC::Ciències de la visió::Optometria::Acomodació i refracció
Descripción
Sumario:The influence of astigmatism on the image formed by a model eye with an intraocular lens (IOL) inserted is analysed. Toric (T-) and non-toric (N-) versions of the same monofocal spherical aberration-free IOL (20 D) were considered, for a range of uncorrected astigmatism from 0.0 to 2.0 D, and two pupils (3.0, 4.5 mm). With the T-IOL, the effect of a rotation error up to 35° was also investigated. An adaptive optics system was used to either compensate or introduce computercontrolled astigmatism. The optical quality was tested by evaluating the modulation transfer function integrated in a range of spatial frequencies from 0 to 50 c/mm in a through-focus analysis. Uncorrected astigmatism degraded the quality of the optical image in the spherical equivalent plane to a similar extent for both IOLs. A model eye with an astigmatism-free cornea plus the N-IOL provided the best image for plane wave illumination. With the T-IOL (1.25 D cyl) the best image was obtained after inducing corneal astigmatism of 0.9D to compensate for the 1.25D cylinder at the IOL plane. A rotation error between the astigmatism axes of the cornea and the T-IOL produced undesired residual astigmatism with an axis direction change. A rotation error up to 10° caused low image degradation.