Assessment of Corneal Epithelial Thickness in Asymmetric Keratoconic Eyes and Normal Eyes Using Fourier Domain Optical Coherence Tomography

Purpose. To compare the characteristics of asymmetric keratoconic eyes and normal eyes by Fourier domain optical coherence tomography (OCT) corneal mapping. Methods. Retrospective corneal and epithelial thickness OCT data for 74 patients were compared in three groups of eyes: keratoconic (n=22) and...

Descripción completa

Detalles Bibliográficos
Autores: Catalan-Lopez, Sara, Cadarso-Suárez, Luis, Esteves, Filipe, Salgado-Borges, Jose, López Ratón, Mónica, Cadarso Suárez, Carmen María
Tipo de recurso: artículo
Fecha de publicación:2016
País:España
Institución:Universidad de Santiago de Compostela (USC)
Repositorio:Minerva. Repositorio Institucional de la Universidad de Santiago de Compostela
Idioma:inglés
OAI Identifier:oai:minerva.usc.gal:10347/16042
Acceso en línea:http://hdl.handle.net/10347/16042
Access Level:acceso abierto
Palabra clave:Materias::Investigación::32 Ciencias médicas::3201 Ciencias clínicas::320109 Oftalmología
id ES_76eda69952beaa0cdd4e1b0fffd8a7b2
oai_identifier_str oai:minerva.usc.gal:10347/16042
network_acronym_str ES
network_name_str España
repository_id_str
spelling Assessment of Corneal Epithelial Thickness in Asymmetric Keratoconic Eyes and Normal Eyes Using Fourier Domain Optical Coherence TomographyCatalan-Lopez, SaraCadarso-Suárez, LuisEsteves, FilipeSalgado-Borges, JoseLópez Ratón, MónicaCadarso Suárez, Carmen MaríaMaterias::Investigación::32 Ciencias médicas::3201 Ciencias clínicas::320109 OftalmologíaPurpose. To compare the characteristics of asymmetric keratoconic eyes and normal eyes by Fourier domain optical coherence tomography (OCT) corneal mapping. Methods. Retrospective corneal and epithelial thickness OCT data for 74 patients were compared in three groups of eyes: keratoconic (n=22) and normal fellow eyes (n=22) in patients with asymmetric keratoconus and normal eyes (n=104) in healthy subjects. Areas under the curve (AUC) of receiver operator characteristic (ROC) curves for each variable were compared across groups to indicate their discrimination capacity. Results. Three variables were found to differ significantly between fellow eyes and normal eyes (all < 0.05 ): minimum corneal thickness, thinnest corneal point, and central corneal thickness. These variables combined showed a high discrimination power to differentiate fellow eyes from normal eyes indicated by an AUC of 0.840 (95% CI: 0.762–0.918). Conclusions. Our findings indicate that topographically normal fellow eyes in patients with very asymmetric keratoconus differ from the eyes of healthy individuals in terms of their corneal epithelial and pachymetry maps. This type of information could be useful for an early diagnosis of keratoconus in topographically normal eyesHindawiUniversidade de Santiago de Compostela. Departamento de Estatística, Análise Matemática e Optimización20162016-01-0120162016-01-01journal articlehttp://purl.org/coar/resource_type/c_6501VoRhttp://purl.org/coar/version/c_970fb48d4fbd8a85info:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10347/16042reponame:Minerva. Repositorio Institucional de la Universidad de Santiago de Compostelainstname:Universidad de Santiago de Compostela (USC)Inglésengopen accesshttp://purl.org/coar/access_right/c_abf2© 2016 S. Catalan et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly citedhttps://creativecommons.org/licenses/by/4.0/info:eu-repo/semantics/openAccessoai:minerva.usc.gal:10347/160422026-06-15T12:47:27Z
dc.title.none.fl_str_mv Assessment of Corneal Epithelial Thickness in Asymmetric Keratoconic Eyes and Normal Eyes Using Fourier Domain Optical Coherence Tomography
title Assessment of Corneal Epithelial Thickness in Asymmetric Keratoconic Eyes and Normal Eyes Using Fourier Domain Optical Coherence Tomography
spellingShingle Assessment of Corneal Epithelial Thickness in Asymmetric Keratoconic Eyes and Normal Eyes Using Fourier Domain Optical Coherence Tomography
Catalan-Lopez, Sara
Materias::Investigación::32 Ciencias médicas::3201 Ciencias clínicas::320109 Oftalmología
title_short Assessment of Corneal Epithelial Thickness in Asymmetric Keratoconic Eyes and Normal Eyes Using Fourier Domain Optical Coherence Tomography
title_full Assessment of Corneal Epithelial Thickness in Asymmetric Keratoconic Eyes and Normal Eyes Using Fourier Domain Optical Coherence Tomography
title_fullStr Assessment of Corneal Epithelial Thickness in Asymmetric Keratoconic Eyes and Normal Eyes Using Fourier Domain Optical Coherence Tomography
title_full_unstemmed Assessment of Corneal Epithelial Thickness in Asymmetric Keratoconic Eyes and Normal Eyes Using Fourier Domain Optical Coherence Tomography
title_sort Assessment of Corneal Epithelial Thickness in Asymmetric Keratoconic Eyes and Normal Eyes Using Fourier Domain Optical Coherence Tomography
dc.creator.none.fl_str_mv Catalan-Lopez, Sara
Cadarso-Suárez, Luis
Esteves, Filipe
Salgado-Borges, Jose
López Ratón, Mónica
Cadarso Suárez, Carmen María
author Catalan-Lopez, Sara
author_facet Catalan-Lopez, Sara
Cadarso-Suárez, Luis
Esteves, Filipe
Salgado-Borges, Jose
López Ratón, Mónica
Cadarso Suárez, Carmen María
author_role author
author2 Cadarso-Suárez, Luis
Esteves, Filipe
Salgado-Borges, Jose
López Ratón, Mónica
Cadarso Suárez, Carmen María
author2_role author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade de Santiago de Compostela. Departamento de Estatística, Análise Matemática e Optimización

dc.subject.none.fl_str_mv Materias::Investigación::32 Ciencias médicas::3201 Ciencias clínicas::320109 Oftalmología
topic Materias::Investigación::32 Ciencias médicas::3201 Ciencias clínicas::320109 Oftalmología
description Purpose. To compare the characteristics of asymmetric keratoconic eyes and normal eyes by Fourier domain optical coherence tomography (OCT) corneal mapping. Methods. Retrospective corneal and epithelial thickness OCT data for 74 patients were compared in three groups of eyes: keratoconic (n=22) and normal fellow eyes (n=22) in patients with asymmetric keratoconus and normal eyes (n=104) in healthy subjects. Areas under the curve (AUC) of receiver operator characteristic (ROC) curves for each variable were compared across groups to indicate their discrimination capacity. Results. Three variables were found to differ significantly between fellow eyes and normal eyes (all < 0.05 ): minimum corneal thickness, thinnest corneal point, and central corneal thickness. These variables combined showed a high discrimination power to differentiate fellow eyes from normal eyes indicated by an AUC of 0.840 (95% CI: 0.762–0.918). Conclusions. Our findings indicate that topographically normal fellow eyes in patients with very asymmetric keratoconus differ from the eyes of healthy individuals in terms of their corneal epithelial and pachymetry maps. This type of information could be useful for an early diagnosis of keratoconus in topographically normal eyes
publishDate 2016
dc.date.none.fl_str_mv 2016
2016-01-01
2016
2016-01-01
dc.type.none.fl_str_mv journal article
http://purl.org/coar/resource_type/c_6501
VoR
http://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.openaire.fl_str_mv info:eu-repo/semantics/article
format article
dc.identifier.none.fl_str_mv http://hdl.handle.net/10347/16042
url http://hdl.handle.net/10347/16042
dc.language.none.fl_str_mv Inglés
eng
language_invalid_str_mv Inglés
language eng
dc.rights.none.fl_str_mv open access
http://purl.org/coar/access_right/c_abf2
https://creativecommons.org/licenses/by/4.0/
dc.rights.openaire.fl_str_mv info:eu-repo/semantics/openAccess
rights_invalid_str_mv open access
http://purl.org/coar/access_right/c_abf2
https://creativecommons.org/licenses/by/4.0/
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Hindawi
publisher.none.fl_str_mv Hindawi
dc.source.none.fl_str_mv reponame:Minerva. Repositorio Institucional de la Universidad de Santiago de Compostela
instname:Universidad de Santiago de Compostela (USC)
instname_str Universidad de Santiago de Compostela (USC)
reponame_str Minerva. Repositorio Institucional de la Universidad de Santiago de Compostela
collection Minerva. Repositorio Institucional de la Universidad de Santiago de Compostela
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869411085786808320
score 15,81155