Quantitative determination of the antitumor alkyl ether phospholipid edelfosine by reversed-phase liquid chromatography-electrospray mass spectrometry: application to cell uptake studies and characterization of drug delivery systems.

Edelfosine is a synthetic alkyl ether phospholipid that represents a promising class of antitumor agents. However, analytical methods to measure these type compounds are scarce. The lack of a reliable methodology to quantify edelfosine is a major problem in ongoing and scheduled preclinical and clin...

Descripción completa

Detalles Bibliográficos
Autores: Blanco-Prieto, M.J. (María José)|||/items/93e177db-635f-456f-b672-b79ef8befc40, Campanero, M.A. (Miguel Angel)|||/items/0023fc84-97ca-4e40-95b4-9fd3c6f755af, Mollinedo, F. (Faustino)|||/items/15ff13d8-71ca-4313-a560-a9fb504fc99d
Tipo de recurso: artículo
Fecha de publicación:2004
País:España
Institución:Universidad de Navarra
Repositorio:Dadun. Depósito Académico Digital de la Universidad de Navarra
Idioma:inglés
OAI Identifier:oai:dadun.unav.edu:10171/22385
Acceso en línea:https://hdl.handle.net/10171/22385
Access Level:acceso abierto
Palabra clave:Edelfosine
Drug delivery systems
Antitumoral agents
Farmacología clínica
Descripción
Sumario:Edelfosine is a synthetic alkyl ether phospholipid that represents a promising class of antitumor agents. However, analytical methods to measure these type compounds are scarce. The lack of a reliable methodology to quantify edelfosine is a major problem in ongoing and scheduled preclinical and clinical trials with this drug. We evaluated the applicability of high-performance liquid chromatography–mass spectrometry to determine edelfosine in biological samples and polymeric delivery systems. Sample pre-treatment involved polymer precipitation or cell lysis with methanol. HPLC separation was performed on an Alltima RPC18 narrow-bore column and edelfosine quantification was done by electrospray ionization mass spectrometry (ESI-MS) using positive ion mode and selected ion monitoring. Assays were linear in the tested range of 0.3–10 μg/ml. The limit of quantification was 0.3 ng/sample in both matrices, namely biological samples and polymeric delivery systems. The interassay precision ranging from 0.79 to 1.49%, with relative errors of −6.7 and 12.8%. Mean extraction recovery was 95.6%. HPLC–ESI-MS is a reliable system for edelfosine analysis and quantification in samples from different sources, combining advantages of full automation (rapidity, ease of use, no need of extensive extraction procedures) with high analytical performance and throughput.