Control, Diagnosis, and Monitoring of Permanent Magnet Synchronous Machines Using Search Coils
Tesis doctoral con mención internacional
| Autor: | |
|---|---|
| Tipo de recurso: | tesis doctoral |
| Fecha de publicación: | 2024 |
| País: | España |
| Institución: | Universidad de Oviedo (UNIOVI) |
| Repositorio: | RUO. Repositorio Institucional de la Universidad de Oviedo |
| Idioma: | inglés |
| OAI Identifier: | oai:digibuo.uniovi.es:10651/72586 |
| Acceso en línea: | https://hdl.handle.net/10651/72586 |
| Access Level: | acceso abierto |
| Palabra clave: | Máquinas síncronas de imanes permanentes (PMSMs) Fallos mecánicos Desmagnetización |
| id |
ES_6cc548ffec2f8dc511d488828fb501ff |
|---|---|
| oai_identifier_str |
oai:digibuo.uniovi.es:10651/72586 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Control, Diagnosis, and Monitoring of Permanent Magnet Synchronous Machines Using Search CoilsControl, diagnóstico y monitorización de máquinas síncronas de imanes permanentes utilizando search coilsOrviz Zapico, Marcos|||0000-0001-5206-2017Máquinas síncronas de imanes permanentes (PMSMs)Fallos mecánicosDesmagnetizaciónTesis doctoral con mención internacionalEn esta tesis, se han abordado aspectos críticos relacionados con el control, monitorización y detección de fallos en las PMSMs. Uno de los fallos más comunes en las PMSMs son las desmagnetizaciones irreversibles de los imanes, las cuales provocan una reducción de prestaciones de la misma, llegando en el límite a la pérdida total de la máquina. Otros tipos de fallos muy habituales que sufren las PMSMs (y cualquier tipo de máquina eléctrica rotativa) son los fallos mecánicos como pueden ser las excentricidades, ya sea estática, dinámica o mixta, y los desalineamientos del rotor.Díaz Reigosa, DavidGuerrero Muñoz, Juan ManuelIngeniería Eléctrica, Electrónica, de Computadores y Sistemas, Departamento de20242024-02-19doctoral thesishttp://purl.org/coar/resource_type/c_db06NAhttp://purl.org/coar/version/c_be7fb7dd8ff6fe43info:eu-repo/semantics/doctoralThesishttps://hdl.handle.net/10651/72586reponame:RUO. Repositorio Institucional de la Universidad de Oviedoinstname:Universidad de Oviedo (UNIOVI)Inglésengopen accesshttp://purl.org/coar/access_right/c_abf2Attribution-NonCommercial-NoDerivatives 4.0 Internationalhttp://creativecommons.org/licenses/by-nc-nd/4.0/info:eu-repo/semantics/openAccessoai:digibuo.uniovi.es:10651/725862026-06-07T06:38:51Z |
| dc.title.none.fl_str_mv |
Control, Diagnosis, and Monitoring of Permanent Magnet Synchronous Machines Using Search Coils Control, diagnóstico y monitorización de máquinas síncronas de imanes permanentes utilizando search coils |
| title |
Control, Diagnosis, and Monitoring of Permanent Magnet Synchronous Machines Using Search Coils |
| spellingShingle |
Control, Diagnosis, and Monitoring of Permanent Magnet Synchronous Machines Using Search Coils Orviz Zapico, Marcos|||0000-0001-5206-2017 Máquinas síncronas de imanes permanentes (PMSMs) Fallos mecánicos Desmagnetización |
| title_short |
Control, Diagnosis, and Monitoring of Permanent Magnet Synchronous Machines Using Search Coils |
| title_full |
Control, Diagnosis, and Monitoring of Permanent Magnet Synchronous Machines Using Search Coils |
| title_fullStr |
Control, Diagnosis, and Monitoring of Permanent Magnet Synchronous Machines Using Search Coils |
| title_full_unstemmed |
Control, Diagnosis, and Monitoring of Permanent Magnet Synchronous Machines Using Search Coils |
| title_sort |
Control, Diagnosis, and Monitoring of Permanent Magnet Synchronous Machines Using Search Coils |
| dc.creator.none.fl_str_mv |
Orviz Zapico, Marcos|||0000-0001-5206-2017 |
| author |
Orviz Zapico, Marcos|||0000-0001-5206-2017 |
| author_facet |
Orviz Zapico, Marcos|||0000-0001-5206-2017 |
| author_role |
author |
| dc.contributor.none.fl_str_mv |
Díaz Reigosa, David Guerrero Muñoz, Juan Manuel Ingeniería Eléctrica, Electrónica, de Computadores y Sistemas, Departamento de |
| dc.subject.none.fl_str_mv |
Máquinas síncronas de imanes permanentes (PMSMs) Fallos mecánicos Desmagnetización |
| topic |
Máquinas síncronas de imanes permanentes (PMSMs) Fallos mecánicos Desmagnetización |
| description |
Tesis doctoral con mención internacional |
| publishDate |
2024 |
| dc.date.none.fl_str_mv |
2024 2024-02-19 |
| dc.type.none.fl_str_mv |
doctoral thesis http://purl.org/coar/resource_type/c_db06 NA http://purl.org/coar/version/c_be7fb7dd8ff6fe43 |
| dc.type.openaire.fl_str_mv |
info:eu-repo/semantics/doctoralThesis |
| format |
doctoralThesis |
| dc.identifier.none.fl_str_mv |
https://hdl.handle.net/10651/72586 |
| url |
https://hdl.handle.net/10651/72586 |
| dc.language.none.fl_str_mv |
Inglés eng |
| language_invalid_str_mv |
Inglés |
| language |
eng |
| dc.rights.none.fl_str_mv |
open access http://purl.org/coar/access_right/c_abf2 Attribution-NonCommercial-NoDerivatives 4.0 International http://creativecommons.org/licenses/by-nc-nd/4.0/ |
| dc.rights.openaire.fl_str_mv |
info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
open access http://purl.org/coar/access_right/c_abf2 Attribution-NonCommercial-NoDerivatives 4.0 International http://creativecommons.org/licenses/by-nc-nd/4.0/ |
| eu_rights_str_mv |
openAccess |
| dc.source.none.fl_str_mv |
reponame:RUO. Repositorio Institucional de la Universidad de Oviedo instname:Universidad de Oviedo (UNIOVI) |
| instname_str |
Universidad de Oviedo (UNIOVI) |
| reponame_str |
RUO. Repositorio Institucional de la Universidad de Oviedo |
| collection |
RUO. Repositorio Institucional de la Universidad de Oviedo |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869410292177305600 |
| score |
15,812429 |