In vitro comparison of the accuracy of four intraoral scanners and three conventional impression methods for two neighboring implants

Purpose: To determine whether the accuracy of two-implant model impressions taken with optical scanners was inferior to that of those taken with elastomeric materials. Materials and Methods: Impressions of a resin reference model with two almost parallel implants were taken using three elastomeric i...

Descripción completa

Detalles Bibliográficos
Autores: Roig, Elena, Garza Garza, Luis Carlos, Maldonado, Natalia, Maia, Paulo, Costa, Santiago, Roig, Miguel, ESPONA, JOSE
Tipo de recurso: artículo
Fecha de publicación:2020
País:España
Institución:Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)
Repositorio:Recercat. Dipósit de la Recerca de Catalunya
OAI Identifier:oai:recercat.cat:20.500.12328/3044
Acceso en línea:http://hdl.handle.net/20.500.12328/3044
https://dx.doi.org/10.1371/journal.pone.0228266
Access Level:acceso abierto
Palabra clave:Implants dentals
Escàners òptics
Resina
Pròtesis d'implants
Implantes dentales
Escáneres ópticos
Prótesis de implantes
Dental implants
Optical scanners
Resin
Implant prostheses
616.3
Descripción
Sumario:Purpose: To determine whether the accuracy of two-implant model impressions taken with optical scanners was inferior to that of those taken with elastomeric materials. Materials and Methods: Impressions of a resin reference model with two almost parallel implants were taken using three elastomeric impressions (closed tray technique, open tray nonsplinted technique and open tray splinted technique) and scanned with four optical scanners (CEREC Omnicam, 3M True Definition Scanner, 3Shape TRIOS3 and Carestream CS 3600). STL files of the different methods were superimposed and analyzed with control software (Geomagic Control X, 3D systems) to determine the mean deviation between scans. Results: Compared to elastomeric impressions, optical impressions showed a significantly improved mean precision. TRIOS3 and CS3600 showed a significantly improved mean trueness compared to that of closed tray, CEREC Omnicam and TrueDefinition. All methods showed a certain degree of implant rotation over their axes, which was significantly higher in the closed tray and the open tray nonsplinted techniques. Conclusions: Optical impressions, taken under these in vitro conditions, showed improved accuracy compared with that of elastomeric impressions.