Design and characterization of immersion ultrasonic transducers for pulsed regime applications
Ultrasonic transducer design is focused to maximize performance in specific applications, usually leading to a complex design and expensive construction and assembly. With the aim to overcome this drawback, a general-purpose immersion ultrasonic transducer for pulsed regime applications have been de...
| Autores: | , , , |
|---|---|
| Tipo de recurso: | artículo |
| Fecha de publicación: | 2019 |
| País: | España |
| Institución: | Universitat Politècnica de Catalunya (UPC) |
| Repositorio: | UPCommons. Portal del coneixement obert de la UPC |
| Idioma: | inglés |
| OAI Identifier: | oai:upcommons.upc.edu:2117/131090 |
| Acceso en línea: | https://hdl.handle.net/2117/131090 https://dx.doi.org/10.1080/10739149.2018.1518876 |
| Access Level: | acceso abierto |
| Palabra clave: | Ultrasonic transducers Ultrasonic transducer Piezoceramic transducer Ultrasonic sensing Transducer design Transductors -- Disseny i construcció Piezoelectricitat Àrees temàtiques de la UPC::Enginyeria de la telecomunicació |
| Sumario: | Ultrasonic transducer design is focused to maximize performance in specific applications, usually leading to a complex design and expensive construction and assembly. With the aim to overcome this drawback, a general-purpose immersion ultrasonic transducer for pulsed regime applications have been developed. The design of each element of the transducer is described in this paper, wherein materials and geometries for each part have been recommended. A simple theoretical model have been proposed in order to predict the form of the received electric signal in the target transducer. The model is based in the assumption that the piezoelectric element acts as an underdamped oscillator, forced by the acoustic field coming from the propagation medium. Excellent agreement between the experimental measurements and the analytical model is achieved. Electrical impedance measurements reveal negligible differences between the resonance frequency of the active element and that of the assembled transducer. The designed devices have been characterized in water, using two identical transducers placed face to face with changeable orientation. Experimental results show a highly linear response and the generation of a collimated acoustic field. The effects of the thickness of the matching layer on the transmission coefficient have been also studied, resulting in a smooth decrease in the received amplitude, which may significantly lower large-scale production costs. |
|---|