Analysis of the Performance of a Passive Downdraught Evaporative Cooling System Driven by Solar Chimneys in a Residential Building by Using an Experimentally Validated TRNSYS Model

[EN] Natural ventilation, combined with a passive cooling system, can provide significant energy savings in the refrigeration of indoor spaces. The performance of these systems is highly dependent on outdoor climatic conditions. The objective of this study was to analyse the feasibility of a passive...

Descripción completa

Detalles Bibliográficos
Autores: Soto, Andrés, Martínez, Pedro, Martínez, Pedro J., Soto Francés, Víctor Manuel|||0000-0002-0244-2668
Tipo de recurso: artículo
Fecha de publicación:2021
País:España
Institución:Universitat Politècnica de València (UPV)
Repositorio:RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Idioma:inglés
OAI Identifier:oai:riunet.upv.es:10251/176292
Acceso en línea:https://riunet.upv.es/handle/10251/176292
Access Level:acceso abierto
Palabra clave:Evaporative cooling
Wind tower
Solar chimneys
Solar cooling
TRNSYS simulation
MAQUINAS Y MOTORES TERMICOS
07.- Asegurar el acceso a energías asequibles, fiables, sostenibles y modernas para todos
Descripción
Sumario:[EN] Natural ventilation, combined with a passive cooling system, can provide significant energy savings in the refrigeration of indoor spaces. The performance of these systems is highly dependent on outdoor climatic conditions. The objective of this study was to analyse the feasibility of a passive, downdraught, evaporative cooling system driven by solar chimneys in different climatic zones by using an experimentally validated simulation tool. This tool combined a ventilation model and a thermal model of the dwelling in which an empirical model of a direct evaporative system made of plastic mesh was implemented. For experimental validation of the combined model, sensors were installed in the dwelling and calibrated in the laboratory. The combined model was applied to Spanish and European cities with different climates. In the simulation, values of cooling energy per volume of air ranging between 0.53 Wh/m(3) and 0.79 Wh/m(3) were obtained for Alicante (hot climate with moderate humidity) and Madrid (hot and dry climate), respectively. In these locations, medium and high applicability was obtained, respectively, in comparison with Burgos (cold climate with moderate humidity) and Bilbao (cold and humid climate), which were low. The evaluation of the reference building in each location allowed establishing a classification in terms of performance, comfort and applicability for each climate.