Hybrid frequency-domain modeling and stability analysis for power systems with grid-following and grid-forming converters

With the increase of the renewable energy generator capacity, the requirements of the power system for grid-connected converters are evolve, which leads to diverse control schemes and increased complexity of systematic stability analysis. Although various frequency-domain models are developed to ide...

Descripción completa

Detalles Bibliográficos
Autores: Liu, Ni, Wang, Hong, Zhou, Weihua, Song, Jie, Zhang, Yiting, Prieto Araujo, Eduardo|||0000-0003-4349-5923, Chen, Zhe
Tipo de recurso: artículo
Fecha de publicación:2025
País:España
Institución:Universitat Politècnica de Catalunya (UPC)
Repositorio:UPCommons. Portal del coneixement obert de la UPC
Idioma:inglés
OAI Identifier:oai:upcommons.upc.edu:2117/426580
Acceso en línea:https://hdl.handle.net/2117/426580
https://dx.doi.org/10.35833/MPCE.2023.000842
Access Level:acceso abierto
Palabra clave:Grid forming
Impedance
Power system stability
Frequency-domain analysis
Analytical models
Grid following
Integrated circuit modeling
Voltage control
Stability criteria
Power system dynamics
Converter
Grid-forming (GFM)
Grid-following (GFL) impedance
Renewable energy
Stability analysis
Frequency-domain model
Àrees temàtiques de la UPC::Enginyeria elèctrica
Descripción
Sumario:With the increase of the renewable energy generator capacity, the requirements of the power system for grid-connected converters are evolve, which leads to diverse control schemes and increased complexity of systematic stability analysis. Although various frequency-domain models are developed to identify oscillation causes, the discrepancies between them are rarely studied. This study aims to clarify these discrepancies and provide circuit insights for stability analysis by using different frequency-domain models. This study emphasizes the limitations of assuming that the transfer function of the self-stable converter does not have right half-plane (RHP) poles. To ensure that the self-stable converters are represented by a frequency-domain model without RHP poles, the applicability of this model of grid-following (GFL) and grid-forming (GFM) converters is discussed. This study recommends that the GFM converters with ideal sources should be represented in parallel with the P/Q-¿/V admittance model rather than the V-I impedance model. Two cases are conducted to illustrate the rationality of the P/Q-¿/V admittance model. Additionally, a hybrid frequency-domain modeling framework and stability criteria are proposed for the power system with several GFL and GFM converters. The stability criteria eliminates the need to check the RHP pole numbers in the non-passive subsystem when applying the Nyquist stability criterion, thereby reducing the complexity of stability analysis. Simulations are carried out to validate the correctness of the frequency-domain model and the stability criteria.