Effect of non-oxidative plasma treatments on the surface properties of poly(p-phenylene terephthalamide) (PPTA) and poly(p-phenylene benzobisoxazole) (PBO) fibres as measured by inverse gas chromatography

It has been shown in previous works that the interfacial adhesion in PPTA- and PBO-epoxy composites can be improved by modifying the surface properties of these high-performance fibres upon exposure to non-oxidative plasma treatments. In this work, the effects developed on both types of polymer surf...

Descripción completa

Detalles Bibliográficos
Autores: Tamargo Martínez, Katia, Montes Morán, Miguel Ángel, Martínez Alonso, Amelia, Díez Tascón, Juan Manuel
Tipo de recurso: artículo
Estado:Versión aceptada para publicación
Fecha de publicación:2020
País:España
Institución:Consejo Superior de Investigaciones Científicas (CSIC)
Repositorio:DIGITAL.CSIC. Repositorio Institucional del CSIC
OAI Identifier:oai:digital.csic.es:10261/234416
Acceso en línea:http://hdl.handle.net/10261/234416
Access Level:acceso abierto
Palabra clave:Inverse gas chromatography (IGC)
Zero coverage
High-performance fibres
Non-oxidative plasma treatments
Thermodynamic surface properties
Descripción
Sumario:It has been shown in previous works that the interfacial adhesion in PPTA- and PBO-epoxy composites can be improved by modifying the surface properties of these high-performance fibres upon exposure to non-oxidative plasma treatments. In this work, the effects developed on both types of polymer surface were examined as a function of treatment gas nature (He or N) and exposure time (one or four minutes) using inverse gas chromatography at infinite dilution (IGC). From the adsorption of n-alkanes, it has been proved that non-oxidative plasma treatments led to energetically heterogeneous surfaces in the case of PPTA, and to low-energy surfaces in the case of PBO. Nevertheless, it was proved with the 1-min plasma treatments (either under helium or under nitrogen) that chemical reactivity was enhanced on the PBO surface. Such a behaviour was ascribed to the presence of low-molecular weight oxidized materials. The mechanisms involved in surface activation of PPTA were not equivalent under He or N exposure. Nitrogen plasma exposure led to a PPTA surface that is chemically reactive as a result of polarity enhancement. Helium plasma-treated PPTA surface was characterized by the presence of branched arrangements that intensified the number of chemical contacts onto reactive sites. Finally, for both fibre sets, if the purpose is to enhance the chemical surface reactivity, it makes no sense to increase the plasma exposure time from 1 to 4 min.