Automatic measurement of choroidal thickness with swept-source optical coherence tomography for clinical follow-up in acute Vogt-Koyanagi-Harada disease
Background: The course of acute Vogt-Koyanagi-Harada is typically assessed qualitatively using indocyanine green angiography. Swept-source optical coherence tomography may provide a safer, non-invasive, more objective approach to follow up. In this study, we assess the clinical value of the automate...
| Autores: | , , , , , |
|---|---|
| Tipo de recurso: | artículo |
| Estado: | Versión publicada |
| Fecha de publicación: | 2016 |
| País: | España |
| Institución: | Universidad de Barcelona |
| Repositorio: | Dipòsit Digital de la UB |
| OAI Identifier: | oai:diposit.ub.edu:2445/218330 |
| Acceso en línea: | https://hdl.handle.net/2445/218330 |
| Access Level: | acceso abierto |
| Palabra clave: | Coroide Malalties autoimmunitàries Tomografia de coherència òptica Choroid Autoimmune diseases Optical coherence tomography |
| id |
ES_62ee772dc97ac64f4e5118724ec8e9ba |
|---|---|
| oai_identifier_str |
oai:diposit.ub.edu:2445/218330 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Automatic measurement of choroidal thickness with swept-source optical coherence tomography for clinical follow-up in acute Vogt-Koyanagi-Harada diseaseGarcia Garcia, OlgaJordán-Cumplido, SaraSubirá-González, OlaiaGarcía Bru, PereArias Barquet, LluísCaminal Mitjana, Josep MariaCoroideMalalties autoimmunitàriesTomografia de coherència òpticaChoroidAutoimmune diseasesOptical coherence tomographyBackground: The course of acute Vogt-Koyanagi-Harada is typically assessed qualitatively using indocyanine green angiography. Swept-source optical coherence tomography may provide a safer, non-invasive, more objective approach to follow up. In this study, we assess the clinical value of the automated measurement capabilities of swept-source tomography to measure choroidal thickness. Design: Prospective, longitudinal case-control study at a tertiary university hospital. Participants: Nine patients with acute Vogt-Koyanagi-Harada disease (18 eyes) and 17 age-matched controls (34 eyes). Methods: Choroidal thickness (subfoveal area and ETDRS grid) was automatically measured with swept-source optical coherence tomography. Changes in thickness were compared to changes in visual acuity and indocyanine green angiography findings to check for correlations. Main outcome measures: Changes in choroidal thickness (micrometers- μm) from baseline. Secondary measures included visual acuity and angiography. Results: At baseline, patients presented significantly greater mean (SD) subfoveal choroidal thickness (666.9 μm [258.3] vs. 302.3 [71.4]) and ETDRS grid choroidal thickness (648.7 μm [260.5] vs. 287.5 [69.3]) than controls (p=0.000). Choroidal thinning and improved vision were associated with treatment while increasing thickness and worsening vision were associated with posterior relapse. In 62.5% of recurrences in tomography, no changes in visual acuity were present; however, all recurrences diagnosed with tomography showed signs of inflammation on angiography. Conclusions: Automatic measurement of choroidal thickness with swept-source optical coherence tomography is a rapid, non-invasive manner of detecting posterior segment recurrences and treatment response in acute Harada patients. Swept-source tomography could reduce the need for angiography to monitor patients with Harada disease.Longdom Publishing2016info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://hdl.handle.net/2445/218330Articles publicats en revistes (Ciències Clíniques)reponame:Dipòsit Digital de la UBinstname:Universidad de BarcelonaInglésReproducció del document publicat a: https://doi.org/10.4172/2155-9570.1000579Journal of Clinical and Experimental Ophthalmology, 2016, vol. 7, num.4https://doi.org/10.4172/2155-9570.1000579cc-by (c) García-García, O. et al., 2016http://creativecommons.org/licenses/by/4.0/info:eu-repo/semantics/openAccessoai:diposit.ub.edu:2445/2183302026-05-27T06:46:51Z |
| dc.title.none.fl_str_mv |
Automatic measurement of choroidal thickness with swept-source optical coherence tomography for clinical follow-up in acute Vogt-Koyanagi-Harada disease |
| title |
Automatic measurement of choroidal thickness with swept-source optical coherence tomography for clinical follow-up in acute Vogt-Koyanagi-Harada disease |
| spellingShingle |
Automatic measurement of choroidal thickness with swept-source optical coherence tomography for clinical follow-up in acute Vogt-Koyanagi-Harada disease Garcia Garcia, Olga Coroide Malalties autoimmunitàries Tomografia de coherència òptica Choroid Autoimmune diseases Optical coherence tomography |
| title_short |
Automatic measurement of choroidal thickness with swept-source optical coherence tomography for clinical follow-up in acute Vogt-Koyanagi-Harada disease |
| title_full |
Automatic measurement of choroidal thickness with swept-source optical coherence tomography for clinical follow-up in acute Vogt-Koyanagi-Harada disease |
| title_fullStr |
Automatic measurement of choroidal thickness with swept-source optical coherence tomography for clinical follow-up in acute Vogt-Koyanagi-Harada disease |
| title_full_unstemmed |
Automatic measurement of choroidal thickness with swept-source optical coherence tomography for clinical follow-up in acute Vogt-Koyanagi-Harada disease |
| title_sort |
Automatic measurement of choroidal thickness with swept-source optical coherence tomography for clinical follow-up in acute Vogt-Koyanagi-Harada disease |
| dc.creator.none.fl_str_mv |
Garcia Garcia, Olga Jordán-Cumplido, Sara Subirá-González, Olaia García Bru, Pere Arias Barquet, Lluís Caminal Mitjana, Josep Maria |
| author |
Garcia Garcia, Olga |
| author_facet |
Garcia Garcia, Olga Jordán-Cumplido, Sara Subirá-González, Olaia García Bru, Pere Arias Barquet, Lluís Caminal Mitjana, Josep Maria |
| author_role |
author |
| author2 |
Jordán-Cumplido, Sara Subirá-González, Olaia García Bru, Pere Arias Barquet, Lluís Caminal Mitjana, Josep Maria |
| author2_role |
author author author author author |
| dc.subject.none.fl_str_mv |
Coroide Malalties autoimmunitàries Tomografia de coherència òptica Choroid Autoimmune diseases Optical coherence tomography |
| topic |
Coroide Malalties autoimmunitàries Tomografia de coherència òptica Choroid Autoimmune diseases Optical coherence tomography |
| description |
Background: The course of acute Vogt-Koyanagi-Harada is typically assessed qualitatively using indocyanine green angiography. Swept-source optical coherence tomography may provide a safer, non-invasive, more objective approach to follow up. In this study, we assess the clinical value of the automated measurement capabilities of swept-source tomography to measure choroidal thickness. Design: Prospective, longitudinal case-control study at a tertiary university hospital. Participants: Nine patients with acute Vogt-Koyanagi-Harada disease (18 eyes) and 17 age-matched controls (34 eyes). Methods: Choroidal thickness (subfoveal area and ETDRS grid) was automatically measured with swept-source optical coherence tomography. Changes in thickness were compared to changes in visual acuity and indocyanine green angiography findings to check for correlations. Main outcome measures: Changes in choroidal thickness (micrometers- μm) from baseline. Secondary measures included visual acuity and angiography. Results: At baseline, patients presented significantly greater mean (SD) subfoveal choroidal thickness (666.9 μm [258.3] vs. 302.3 [71.4]) and ETDRS grid choroidal thickness (648.7 μm [260.5] vs. 287.5 [69.3]) than controls (p=0.000). Choroidal thinning and improved vision were associated with treatment while increasing thickness and worsening vision were associated with posterior relapse. In 62.5% of recurrences in tomography, no changes in visual acuity were present; however, all recurrences diagnosed with tomography showed signs of inflammation on angiography. Conclusions: Automatic measurement of choroidal thickness with swept-source optical coherence tomography is a rapid, non-invasive manner of detecting posterior segment recurrences and treatment response in acute Harada patients. Swept-source tomography could reduce the need for angiography to monitor patients with Harada disease. |
| publishDate |
2016 |
| dc.date.none.fl_str_mv |
2016 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
https://hdl.handle.net/2445/218330 |
| url |
https://hdl.handle.net/2445/218330 |
| dc.language.none.fl_str_mv |
Inglés |
| language_invalid_str_mv |
Inglés |
| dc.relation.none.fl_str_mv |
Reproducció del document publicat a: https://doi.org/10.4172/2155-9570.1000579 Journal of Clinical and Experimental Ophthalmology, 2016, vol. 7, num.4 https://doi.org/10.4172/2155-9570.1000579 |
| dc.rights.none.fl_str_mv |
cc-by (c) García-García, O. et al., 2016 http://creativecommons.org/licenses/by/4.0/ info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
cc-by (c) García-García, O. et al., 2016 http://creativecommons.org/licenses/by/4.0/ |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
Longdom Publishing |
| publisher.none.fl_str_mv |
Longdom Publishing |
| dc.source.none.fl_str_mv |
Articles publicats en revistes (Ciències Clíniques) reponame:Dipòsit Digital de la UB instname:Universidad de Barcelona |
| instname_str |
Universidad de Barcelona |
| reponame_str |
Dipòsit Digital de la UB |
| collection |
Dipòsit Digital de la UB |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869409534577999872 |
| score |
15,81155 |