Mechanical Properties and Corrosion Behavior of Ti6Al4V Particles Obtained by Implantoplasty: An In Vitro Study. Part II.

In the field of implant dentistry there are several mechanisms by which metal particles can be released into the peri-implant tissues, such as implant insertion, corrosion, wear, or surface decontamination techniques. The aim of this study was to evaluate the corrosion behavior of Ti6Al4V particles...

Descripción completa

Detalles Bibliográficos
Autores: Toledano Serrabona, Jorge, Sánchez Garcés, Ma. Ángeles, Gay Escoda, Cosme, Valmaseda Castellón, Eduardo, Camps Font, Octavi, Verdeguer, Pablo, Molmeneu, Meritxell, Gil, Franscisco Javier
Tipo de recurso: artículo
Estado:Versión publicada
Fecha de publicación:2021
País:España
Institución:Universidad de Barcelona
Repositorio:Dipòsit Digital de la UB
OAI Identifier:oai:diposit.ub.edu:2445/181540
Acceso en línea:https://hdl.handle.net/2445/181540
Access Level:acceso abierto
Palabra clave:Implants dentals
Corrosió i anticorrosius
Dental implants
Corrosion and anti-corrosives
id ES_61ccfabcb2ce99e01de9a24d3fbebdcd
oai_identifier_str oai:diposit.ub.edu:2445/181540
network_acronym_str ES
network_name_str España
repository_id_str
spelling Mechanical Properties and Corrosion Behavior of Ti6Al4V Particles Obtained by Implantoplasty: An In Vitro Study. Part II.Toledano Serrabona, JorgeSánchez Garcés, Ma. ÁngelesGay Escoda, CosmeValmaseda Castellón, EduardoCamps Font, OctaviVerdeguer, PabloMolmeneu, MeritxellGil, Franscisco JavierImplants dentalsCorrosió i anticorrosiusDental implantsCorrosion and anti-corrosivesIn the field of implant dentistry there are several mechanisms by which metal particles can be released into the peri-implant tissues, such as implant insertion, corrosion, wear, or surface decontamination techniques. The aim of this study was to evaluate the corrosion behavior of Ti6Al4V particles released during implantoplasty of dental implants treated due to periimplantitis. A standardized protocol was used to obtain metal particles produced during polishing the surface of Ti6Al4V dental implants. Physicochemical and biological characterization of the particles were described in Part I, while the mechanical properties and corrosion behavior have been studied in this study. Mechanical properties were determined by means of nanoindentation and X-ray diffraction. Corrosion resistance was evaluated by electrochemical testing in an artificial saliva medium. Corrosion parameters such as critical current density (icr), corrosion potential (ECORR), and passive current density (iCORR) have been determined. The samples for electrochemical behavior were discs of Ti6Al4V as-received and discs with the same mechanical properties and internal stresses than the particles from implantoplasty. The discs were cold-worked at 12.5% in order to achieve the same properties (hardness, strength, plastic strain, and residual stresses). The implantoplasty particles showed a higher hardness, strength, elastic modulus, and lower strain to fracture and a compressive residual stress. Resistance to corrosion of the implantoplasty particles decreased, and surface pitting was observed. This fact is due to the increase of the residual stress on the surfaces which favor the electrochemical reactions. The values of corrosion potential can be achieved in normal conditions and produce corroded debris which could be cytotoxic and cause tattooing in the soft tissues.MDPI2021info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://hdl.handle.net/2445/181540Articles publicats en revistes (Odontoestomatologia)reponame:Dipòsit Digital de la UBinstname:Universidad de BarcelonaInglésReproducció del document publicat a: https://doi.org/10.3390/ma14216507Materials, 2021, vol. 14, num. 21, p. 6519https://doi.org/10.3390/ma14216507cc-by (c) Toledano Serrabona, Jorge et al., 2021https://creativecommons.org/licenses/by/4.0/info:eu-repo/semantics/openAccessoai:diposit.ub.edu:2445/1815402026-05-27T06:46:51Z
dc.title.none.fl_str_mv Mechanical Properties and Corrosion Behavior of Ti6Al4V Particles Obtained by Implantoplasty: An In Vitro Study. Part II.
title Mechanical Properties and Corrosion Behavior of Ti6Al4V Particles Obtained by Implantoplasty: An In Vitro Study. Part II.
spellingShingle Mechanical Properties and Corrosion Behavior of Ti6Al4V Particles Obtained by Implantoplasty: An In Vitro Study. Part II.
Toledano Serrabona, Jorge
Implants dentals
Corrosió i anticorrosius
Dental implants
Corrosion and anti-corrosives
title_short Mechanical Properties and Corrosion Behavior of Ti6Al4V Particles Obtained by Implantoplasty: An In Vitro Study. Part II.
title_full Mechanical Properties and Corrosion Behavior of Ti6Al4V Particles Obtained by Implantoplasty: An In Vitro Study. Part II.
title_fullStr Mechanical Properties and Corrosion Behavior of Ti6Al4V Particles Obtained by Implantoplasty: An In Vitro Study. Part II.
title_full_unstemmed Mechanical Properties and Corrosion Behavior of Ti6Al4V Particles Obtained by Implantoplasty: An In Vitro Study. Part II.
title_sort Mechanical Properties and Corrosion Behavior of Ti6Al4V Particles Obtained by Implantoplasty: An In Vitro Study. Part II.
dc.creator.none.fl_str_mv Toledano Serrabona, Jorge
Sánchez Garcés, Ma. Ángeles
Gay Escoda, Cosme
Valmaseda Castellón, Eduardo
Camps Font, Octavi
Verdeguer, Pablo
Molmeneu, Meritxell
Gil, Franscisco Javier
author Toledano Serrabona, Jorge
author_facet Toledano Serrabona, Jorge
Sánchez Garcés, Ma. Ángeles
Gay Escoda, Cosme
Valmaseda Castellón, Eduardo
Camps Font, Octavi
Verdeguer, Pablo
Molmeneu, Meritxell
Gil, Franscisco Javier
author_role author
author2 Sánchez Garcés, Ma. Ángeles
Gay Escoda, Cosme
Valmaseda Castellón, Eduardo
Camps Font, Octavi
Verdeguer, Pablo
Molmeneu, Meritxell
Gil, Franscisco Javier
author2_role author
author
author
author
author
author
author
dc.subject.none.fl_str_mv Implants dentals
Corrosió i anticorrosius
Dental implants
Corrosion and anti-corrosives
topic Implants dentals
Corrosió i anticorrosius
Dental implants
Corrosion and anti-corrosives
description In the field of implant dentistry there are several mechanisms by which metal particles can be released into the peri-implant tissues, such as implant insertion, corrosion, wear, or surface decontamination techniques. The aim of this study was to evaluate the corrosion behavior of Ti6Al4V particles released during implantoplasty of dental implants treated due to periimplantitis. A standardized protocol was used to obtain metal particles produced during polishing the surface of Ti6Al4V dental implants. Physicochemical and biological characterization of the particles were described in Part I, while the mechanical properties and corrosion behavior have been studied in this study. Mechanical properties were determined by means of nanoindentation and X-ray diffraction. Corrosion resistance was evaluated by electrochemical testing in an artificial saliva medium. Corrosion parameters such as critical current density (icr), corrosion potential (ECORR), and passive current density (iCORR) have been determined. The samples for electrochemical behavior were discs of Ti6Al4V as-received and discs with the same mechanical properties and internal stresses than the particles from implantoplasty. The discs were cold-worked at 12.5% in order to achieve the same properties (hardness, strength, plastic strain, and residual stresses). The implantoplasty particles showed a higher hardness, strength, elastic modulus, and lower strain to fracture and a compressive residual stress. Resistance to corrosion of the implantoplasty particles decreased, and surface pitting was observed. This fact is due to the increase of the residual stress on the surfaces which favor the electrochemical reactions. The values of corrosion potential can be achieved in normal conditions and produce corroded debris which could be cytotoxic and cause tattooing in the soft tissues.
publishDate 2021
dc.date.none.fl_str_mv 2021
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://hdl.handle.net/2445/181540
url https://hdl.handle.net/2445/181540
dc.language.none.fl_str_mv Inglés
language_invalid_str_mv Inglés
dc.relation.none.fl_str_mv Reproducció del document publicat a: https://doi.org/10.3390/ma14216507
Materials, 2021, vol. 14, num. 21, p. 6519
https://doi.org/10.3390/ma14216507
dc.rights.none.fl_str_mv cc-by (c) Toledano Serrabona, Jorge et al., 2021
https://creativecommons.org/licenses/by/4.0/
info:eu-repo/semantics/openAccess
rights_invalid_str_mv cc-by (c) Toledano Serrabona, Jorge et al., 2021
https://creativecommons.org/licenses/by/4.0/
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv MDPI
publisher.none.fl_str_mv MDPI
dc.source.none.fl_str_mv Articles publicats en revistes (Odontoestomatologia)
reponame:Dipòsit Digital de la UB
instname:Universidad de Barcelona
instname_str Universidad de Barcelona
reponame_str Dipòsit Digital de la UB
collection Dipòsit Digital de la UB
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869409445637783552
score 15.300724