Does Function Determine the Structure? Changes in Flexor Hallucis Longus Muscle and the Associated Performance Related to Dance Modality: A Cross-Sectional Study
Este artículo pertenece al número especial: Ultrasound in Sports Medicine: Current Concepts and Advances
| Autores: | , , , , , , |
|---|---|
| Tipo de recurso: | artículo |
| Estado: | Versión publicada |
| Fecha de publicación: | 2020 |
| País: | España |
| Institución: | Universidad de Sevilla (US) |
| Repositorio: | idUS. Depósito de Investigación de la Universidad de Sevilla |
| OAI Identifier: | oai:idus.us.es:11441/100384 |
| Acceso en línea: | https://hdl.handle.net/11441/100384 https://doi.org/10.3390/medicina56040186 |
| Access Level: | acceso abierto |
| Palabra clave: | Biomechanics Dancer Ultrasound Muscle size Flexor hallucis longus Physiological testing |
| id |
ES_61aa57d61bee8a2a9187eb9ccca00aa4 |
|---|---|
| oai_identifier_str |
oai:idus.us.es:11441/100384 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Does Function Determine the Structure? Changes in Flexor Hallucis Longus Muscle and the Associated Performance Related to Dance Modality: A Cross-Sectional StudyCruz Torres, Blanca de laBarrera García-Martín, IreneCueva Reguera, Mónica de laBravo Aguilar, MaríaBlanco Morales, MaríaNavarro Flores, EmmanuelAbuín Porras, VanesaBiomechanicsDancerUltrasoundMuscle sizeFlexor hallucis longusPhysiological testingEste artículo pertenece al número especial: Ultrasound in Sports Medicine: Current Concepts and AdvancesBackground and Objectives: Flexor hallucis longus pathology is one of the most common conditions of the ankle and foot in dancers, due to the high demand of dance movements performed in an extreme plantar flexion and dorsiflexion range of motion. The objectives of this study were to determine the bilateral differences between the thickness and cross-sectional area of the flexor hallucis longus muscle in dancers, to establish possible differences between dance modalities, and to analyze whether there is a correlation between ultrasonographic parameters or performance variables and the dance modality. Material and Methods: A sample of 50 (29 classical and 21 contemporary) full-time pre-professional female dancers were included in the study. The thickness and cross-sectional area of the flexor hallucis longus muscle were evaluated for both limbs using ultrasound imaging. The range of movement of the first metatarsophalangeal joint was measured using functional extension with maximal ankle plantarflexion, balance was measured in a unilateral stance with the heel raised, endurance was evaluated through a modified heel rise fatigue test, and a counter movement jump to assess the vertical jump performance was measured bilaterally. Results: There were no significant differences recorded between the dominant and non-dominant limbs for each variable, within both groups. Contemporary dancers showed a greater thickness and cross-sectional area of the flexor hallucis longus muscle than classical dancers. However, classical dancers showed an increase of balance, endurance, range of movement of the first metatarsophalangeal joint, and counter movement jump with respect to contemporary dancers. Conclusion: Bilateral symmetry was identified in all variables for both groups. The size and performance of the flexor hallucis longus muscle may be influenced by the specific nature of dance modalityMDPIFisioterapia2020info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfapplication/pdfhttps://hdl.handle.net/11441/100384https://doi.org/10.3390/medicina56040186reponame:idUS. Depósito de Investigación de la Universidad de Sevillainstname:Universidad de Sevilla (US)InglésMedicina, 56 (4)https://doi.org/10.3390/medicina56040186info:eu-repo/semantics/openAccessoai:idus.us.es:11441/1003842026-06-17T12:51:07Z |
| dc.title.none.fl_str_mv |
Does Function Determine the Structure? Changes in Flexor Hallucis Longus Muscle and the Associated Performance Related to Dance Modality: A Cross-Sectional Study |
| title |
Does Function Determine the Structure? Changes in Flexor Hallucis Longus Muscle and the Associated Performance Related to Dance Modality: A Cross-Sectional Study |
| spellingShingle |
Does Function Determine the Structure? Changes in Flexor Hallucis Longus Muscle and the Associated Performance Related to Dance Modality: A Cross-Sectional Study Cruz Torres, Blanca de la Biomechanics Dancer Ultrasound Muscle size Flexor hallucis longus Physiological testing |
| title_short |
Does Function Determine the Structure? Changes in Flexor Hallucis Longus Muscle and the Associated Performance Related to Dance Modality: A Cross-Sectional Study |
| title_full |
Does Function Determine the Structure? Changes in Flexor Hallucis Longus Muscle and the Associated Performance Related to Dance Modality: A Cross-Sectional Study |
| title_fullStr |
Does Function Determine the Structure? Changes in Flexor Hallucis Longus Muscle and the Associated Performance Related to Dance Modality: A Cross-Sectional Study |
| title_full_unstemmed |
Does Function Determine the Structure? Changes in Flexor Hallucis Longus Muscle and the Associated Performance Related to Dance Modality: A Cross-Sectional Study |
| title_sort |
Does Function Determine the Structure? Changes in Flexor Hallucis Longus Muscle and the Associated Performance Related to Dance Modality: A Cross-Sectional Study |
| dc.creator.none.fl_str_mv |
Cruz Torres, Blanca de la Barrera García-Martín, Irene Cueva Reguera, Mónica de la Bravo Aguilar, María Blanco Morales, María Navarro Flores, Emmanuel Abuín Porras, Vanesa |
| author |
Cruz Torres, Blanca de la |
| author_facet |
Cruz Torres, Blanca de la Barrera García-Martín, Irene Cueva Reguera, Mónica de la Bravo Aguilar, María Blanco Morales, María Navarro Flores, Emmanuel Abuín Porras, Vanesa |
| author_role |
author |
| author2 |
Barrera García-Martín, Irene Cueva Reguera, Mónica de la Bravo Aguilar, María Blanco Morales, María Navarro Flores, Emmanuel Abuín Porras, Vanesa |
| author2_role |
author author author author author author |
| dc.contributor.none.fl_str_mv |
Fisioterapia |
| dc.subject.none.fl_str_mv |
Biomechanics Dancer Ultrasound Muscle size Flexor hallucis longus Physiological testing |
| topic |
Biomechanics Dancer Ultrasound Muscle size Flexor hallucis longus Physiological testing |
| description |
Este artículo pertenece al número especial: Ultrasound in Sports Medicine: Current Concepts and Advances |
| publishDate |
2020 |
| dc.date.none.fl_str_mv |
2020 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
https://hdl.handle.net/11441/100384 https://doi.org/10.3390/medicina56040186 |
| url |
https://hdl.handle.net/11441/100384 https://doi.org/10.3390/medicina56040186 |
| dc.language.none.fl_str_mv |
Inglés |
| language_invalid_str_mv |
Inglés |
| dc.relation.none.fl_str_mv |
Medicina, 56 (4) https://doi.org/10.3390/medicina56040186 |
| dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf application/pdf |
| dc.publisher.none.fl_str_mv |
MDPI |
| publisher.none.fl_str_mv |
MDPI |
| dc.source.none.fl_str_mv |
reponame:idUS. Depósito de Investigación de la Universidad de Sevilla instname:Universidad de Sevilla (US) |
| instname_str |
Universidad de Sevilla (US) |
| reponame_str |
idUS. Depósito de Investigación de la Universidad de Sevilla |
| collection |
idUS. Depósito de Investigación de la Universidad de Sevilla |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869409434429554688 |
| score |
15,301603 |