How to achieve full liquid conditions at the capillary tube inlet of a household refrigerator
[EN] The capillary tube with a liquid-to-suction heat exchanger (CT-LSHX) is a component that is widely used in household refrigerators. Recent works have indicated that even when measuring subcooled conditions at the condenser outlet, the condition at the capillary tube inlet is a two-phase flow. T...
| Autores: | , , |
|---|---|
| Tipo de recurso: | artículo |
| Fecha de publicación: | 2019 |
| País: | España |
| Institución: | Universitat Politècnica de València (UPV) |
| Repositorio: | RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia |
| Idioma: | inglés |
| OAI Identifier: | oai:riunet.upv.es:10251/140938 |
| Acceso en línea: | https://riunet.upv.es/handle/10251/140938 |
| Access Level: | acceso abierto |
| Palabra clave: | Household refrigerator Capillary tube inlet Refrigerant visualization Non-equilibrium Subcooled vapor COP MAQUINAS Y MOTORES TERMICOS |
| id |
ES_5f75ea417caf2c5237bceefcf916647b |
|---|---|
| oai_identifier_str |
oai:riunet.upv.es:10251/140938 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
How to achieve full liquid conditions at the capillary tube inlet of a household refrigeratorBardoulet, LaetitiaCorberán, José M.Santiago Martínez-BallesterHousehold refrigeratorCapillary tube inletRefrigerant visualizationNon-equilibriumSubcooled vaporCOPMAQUINAS Y MOTORES TERMICOS[EN] The capillary tube with a liquid-to-suction heat exchanger (CT-LSHX) is a component that is widely used in household refrigerators. Recent works have indicated that even when measuring subcooled conditions at the condenser outlet, the condition at the capillary tube inlet is a two-phase flow. The present work was dedicated to analyzing the actual refrigerant conditions at the capillary tube inlet and to investigating how full liquid conditions could be achieved. The research was performed using a typical household refrigerator with corresponding fresh food and freezer compartments, replacing the original refrigerant-to-air condenser with a refrigerant-to-water condenser. This allowed, first, the condensation conditions to be controlled and, second, the estimation of the refrigerant conditions at the condenser outlet from the heat exchanger balance. The obtained results indicated the presence of a non-equilibrium two-phase flow, composed of subcooled vapor and subcooled liquid, at the capillary tube inlet, with both liquid and vapor entering the capillary tube as a vortex with small, fast fluctuations of the liquid level. This non-equilibrium indicated that the subcooling, evaluated from the pressure and temperature of the refrigerant at the condenser outlet, was only apparent and did not allow the evaluation of the actual enthalpy. Finally, by using a smaller capillary tube diameter and increasing the compressor speed, full liquid conditions at the capillary tube inlet were achieved. Furthermore, a performance comparison between the original and the new design revealed that the COP was higher with full liquid conditions.In this project, the work of Laetitia Bardoulet was partially supported by the Santiago Grisolia 2015 program, which is funded by the Generalitat Valenciana, with the reference number GRISOLIA/2015/021.ElsevierGeneralitat ValencianaRepositorio Institucional de la Universitat Politècnica de València Riunet20192019-04-01journal articlehttp://purl.org/coar/resource_type/c_6501VoRhttp://purl.org/coar/version/c_970fb48d4fbd8a85info:eu-repo/semantics/articleapplication/pdfapplication/pdfhttps://riunet.upv.es/handle/10251/140938reponame:RiuNet. Repositorio Institucional de la Universitat Politécnica de Valénciainstname:Universitat Politècnica de València (UPV)InglésengGeneralitat Valenciana https://doi.org/10.13039/501100003359 GRISOLIA%2F2015%2F021open accesshttp://purl.org/coar/access_right/c_abf2Reserva de todos los derechoshttp://rightsstatements.org/vocab/InC/1.0/info:eu-repo/semantics/openAccessoai:riunet.upv.es:10251/1409382026-06-13T07:49:27Z |
| dc.title.none.fl_str_mv |
How to achieve full liquid conditions at the capillary tube inlet of a household refrigerator |
| title |
How to achieve full liquid conditions at the capillary tube inlet of a household refrigerator |
| spellingShingle |
How to achieve full liquid conditions at the capillary tube inlet of a household refrigerator Bardoulet, Laetitia Household refrigerator Capillary tube inlet Refrigerant visualization Non-equilibrium Subcooled vapor COP MAQUINAS Y MOTORES TERMICOS |
| title_short |
How to achieve full liquid conditions at the capillary tube inlet of a household refrigerator |
| title_full |
How to achieve full liquid conditions at the capillary tube inlet of a household refrigerator |
| title_fullStr |
How to achieve full liquid conditions at the capillary tube inlet of a household refrigerator |
| title_full_unstemmed |
How to achieve full liquid conditions at the capillary tube inlet of a household refrigerator |
| title_sort |
How to achieve full liquid conditions at the capillary tube inlet of a household refrigerator |
| dc.creator.none.fl_str_mv |
Bardoulet, Laetitia Corberán, José M. Santiago Martínez-Ballester |
| author |
Bardoulet, Laetitia |
| author_facet |
Bardoulet, Laetitia Corberán, José M. Santiago Martínez-Ballester |
| author_role |
author |
| author2 |
Corberán, José M. Santiago Martínez-Ballester |
| author2_role |
author author |
| dc.contributor.none.fl_str_mv |
Generalitat Valenciana Repositorio Institucional de la Universitat Politècnica de València Riunet |
| dc.subject.none.fl_str_mv |
Household refrigerator Capillary tube inlet Refrigerant visualization Non-equilibrium Subcooled vapor COP MAQUINAS Y MOTORES TERMICOS |
| topic |
Household refrigerator Capillary tube inlet Refrigerant visualization Non-equilibrium Subcooled vapor COP MAQUINAS Y MOTORES TERMICOS |
| description |
[EN] The capillary tube with a liquid-to-suction heat exchanger (CT-LSHX) is a component that is widely used in household refrigerators. Recent works have indicated that even when measuring subcooled conditions at the condenser outlet, the condition at the capillary tube inlet is a two-phase flow. The present work was dedicated to analyzing the actual refrigerant conditions at the capillary tube inlet and to investigating how full liquid conditions could be achieved. The research was performed using a typical household refrigerator with corresponding fresh food and freezer compartments, replacing the original refrigerant-to-air condenser with a refrigerant-to-water condenser. This allowed, first, the condensation conditions to be controlled and, second, the estimation of the refrigerant conditions at the condenser outlet from the heat exchanger balance. The obtained results indicated the presence of a non-equilibrium two-phase flow, composed of subcooled vapor and subcooled liquid, at the capillary tube inlet, with both liquid and vapor entering the capillary tube as a vortex with small, fast fluctuations of the liquid level. This non-equilibrium indicated that the subcooling, evaluated from the pressure and temperature of the refrigerant at the condenser outlet, was only apparent and did not allow the evaluation of the actual enthalpy. Finally, by using a smaller capillary tube diameter and increasing the compressor speed, full liquid conditions at the capillary tube inlet were achieved. Furthermore, a performance comparison between the original and the new design revealed that the COP was higher with full liquid conditions. |
| publishDate |
2019 |
| dc.date.none.fl_str_mv |
2019 2019-04-01 |
| dc.type.none.fl_str_mv |
journal article http://purl.org/coar/resource_type/c_6501 VoR http://purl.org/coar/version/c_970fb48d4fbd8a85 |
| dc.type.openaire.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| dc.identifier.none.fl_str_mv |
https://riunet.upv.es/handle/10251/140938 |
| url |
https://riunet.upv.es/handle/10251/140938 |
| dc.language.none.fl_str_mv |
Inglés eng |
| language_invalid_str_mv |
Inglés |
| language |
eng |
| dc.relation.none.fl_str_mv |
Generalitat Valenciana https://doi.org/10.13039/501100003359 GRISOLIA%2F2015%2F021 |
| dc.rights.none.fl_str_mv |
open access http://purl.org/coar/access_right/c_abf2 Reserva de todos los derechos http://rightsstatements.org/vocab/InC/1.0/ |
| dc.rights.openaire.fl_str_mv |
info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
open access http://purl.org/coar/access_right/c_abf2 Reserva de todos los derechos http://rightsstatements.org/vocab/InC/1.0/ |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf application/pdf |
| dc.publisher.none.fl_str_mv |
Elsevier |
| publisher.none.fl_str_mv |
Elsevier |
| dc.source.none.fl_str_mv |
reponame:RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia instname:Universitat Politècnica de València (UPV) |
| instname_str |
Universitat Politècnica de València (UPV) |
| reponame_str |
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia |
| collection |
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869409208138465280 |
| score |
15.301603 |