Measurement of transmission loss with a standing wave tube in porous materials with and without open cells porosity

The ability of the standing wave tube to measure the sound transmission loss of porous materials, which is the subject of the standard ASTM E2611-17, is studied with six porous materials, three of them with open cell porosity, the other three with closed cell porosity. We find an intrinsic obstacle...

ver descrição completa

Detalhes bibliográficos
Autores: Caballol Bartolomé, David, Raposo, Alvaro P.
Formato: artículo
Fecha de publicación:2020
País:España
Recursos:Consejo General de la Arquitectura Técnica de España (CGATE)
Repositorio:RIARTE
OAI Identifier:oai:www.riarte.es:20.500.12251/1946
Acesso em linha:http://hdl.handle.net/20.500.12251/1946
https://doi.org/10.1016/j.conbuildmat.2020.119297
Access Level:acceso abierto
Palavra-chave:Porosidad
Aislamiento acústico
Absorción acústica
Emisión acústica
Tubo de ondas estacionarias Kundt
Ensayos (propiedades o materiales)
Material de construcción
2201.02 Acústica Arquitectónica
2201.01 Propiedades Acústicas de Los Sólidos
3313.04 Material de Construcción
3312.12 Ensayo de Materiales
3311.02 Ingeniería de Control
3311.17 Equipos de Verificación
Descrição
Resumo:The ability of the standing wave tube to measure the sound transmission loss of porous materials, which is the subject of the standard ASTM E2611-17, is studied with six porous materials, three of them with open cell porosity, the other three with closed cell porosity. We find an intrinsic obstacle in the procedure with the latter materials because the high variability of the measured data makes the results unreliable. We have also tested the two different ways of performing the measurements, by means of two or four microphones, both of which are allowed by the standard, and compared the results. The outcome cannot be distinguished in the case of open-cell porosity materials, which is the expected behaviour, while it gives different results in some of the closed-cell materials, although at this point we already know these materials not to be well suited to be measured with the tube. © 2020 Elsevier Ltd