Fracture resistance after implantoplasty in three implant-abutment connection designs
Background: To assess the effect of implantoplasty and implant-abutment design on the fracture resistance and macroscopic morphology of narrow-diameter (3.5 mm) dental implants. Material and Methods: Screw-shaped titanium dental implants (n = 48) were studied in vitro. Three groups (n = 16) were est...
| Autores: | , , , , , |
|---|---|
| Formato: | artículo |
| Estado: | Versión publicada |
| Fecha de publicación: | 2020 |
| País: | España |
| Recursos: | Universidad de Barcelona |
| Repositorio: | Dipòsit Digital de la UB |
| OAI Identifier: | oai:diposit.ub.edu:2445/173493 |
| Acesso em linha: | https://hdl.handle.net/2445/173493 |
| Access Level: | acceso abierto |
| Palavra-chave: | Implants dentals intraossis Cirurgia dental Endosseous dental implants Dental surgery |
| id |
ES_5da12ff106be9e466d4e50f1a1bcca2b |
|---|---|
| oai_identifier_str |
oai:diposit.ub.edu:2445/173493 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Fracture resistance after implantoplasty in three implant-abutment connection designsCamps Font, OctaviGonzález-Barnadas, AlbertMir Mari, JavierBarbosa de Figueiredo, Rui PedroGay Escoda, CosmeValmaseda Castellón, EduardoImplants dentals intraossisCirurgia dentalEndosseous dental implantsDental surgeryBackground: To assess the effect of implantoplasty and implant-abutment design on the fracture resistance and macroscopic morphology of narrow-diameter (3.5 mm) dental implants. Material and Methods: Screw-shaped titanium dental implants (n = 48) were studied in vitro. Three groups (n = 16) were established, based on implant-abutment connection type: external hexagon, internal hexagon and conical. Eight implants from each group were subjected to an implantoplasty procedure; the remaining 8 implants served as controls. Implant wall thickness was recorded. All samples were subjected to a static strength test. Results: The mean wall thickness reductions varied between 106.46 and 153.75 gm. The mean fracture strengths for the control and test groups were, respectively, 1211.90 +/- 89.95 N and 873.11 +/- 92.37 N in the external hexagon implants; 918.41 +/- 97.19 N and 661.29 +/- 58.03 N in the internal hexagon implants; and 1058.67 +/- 114.05 N and 747.32 +/- 90.05 N in the conical connection implants. Implant wall thickness and fracture resistance (P < 0.001) showed a positive correlation. Fracture strength was influenced by both implantoplasty (P < 0.001) and connection type (P < 0.001). Conclusions: Implantoplasty in diameter-reduced implants decreases implant wall thickness and fracture resistance, and varies depending on the implant-abutment connection. Internal hexagon and conical connection implants seem to be more prone to fracture after implantoplasty.Medicina Oral SL2020info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://hdl.handle.net/2445/173493Articles publicats en revistes (Institut d'lnvestigació Biomèdica de Bellvitge (IDIBELL))reponame:Dipòsit Digital de la UBinstname:Universidad de BarcelonaInglésReproducció del document publicat a: https://doi.org/10.4317/medoral.23700Medicina Oral Patologia Oral y Cirugia Bucal, 2020, vol. 25, num. 5, p. e691-e699https://doi.org/10.4317/medoral.23700(c) Medicina Oral SL, 2020info:eu-repo/semantics/openAccessoai:diposit.ub.edu:2445/1734932026-05-27T06:46:51Z |
| dc.title.none.fl_str_mv |
Fracture resistance after implantoplasty in three implant-abutment connection designs |
| title |
Fracture resistance after implantoplasty in three implant-abutment connection designs |
| spellingShingle |
Fracture resistance after implantoplasty in three implant-abutment connection designs Camps Font, Octavi Implants dentals intraossis Cirurgia dental Endosseous dental implants Dental surgery |
| title_short |
Fracture resistance after implantoplasty in three implant-abutment connection designs |
| title_full |
Fracture resistance after implantoplasty in three implant-abutment connection designs |
| title_fullStr |
Fracture resistance after implantoplasty in three implant-abutment connection designs |
| title_full_unstemmed |
Fracture resistance after implantoplasty in three implant-abutment connection designs |
| title_sort |
Fracture resistance after implantoplasty in three implant-abutment connection designs |
| dc.creator.none.fl_str_mv |
Camps Font, Octavi González-Barnadas, Albert Mir Mari, Javier Barbosa de Figueiredo, Rui Pedro Gay Escoda, Cosme Valmaseda Castellón, Eduardo |
| author |
Camps Font, Octavi |
| author_facet |
Camps Font, Octavi González-Barnadas, Albert Mir Mari, Javier Barbosa de Figueiredo, Rui Pedro Gay Escoda, Cosme Valmaseda Castellón, Eduardo |
| author_role |
author |
| author2 |
González-Barnadas, Albert Mir Mari, Javier Barbosa de Figueiredo, Rui Pedro Gay Escoda, Cosme Valmaseda Castellón, Eduardo |
| author2_role |
author author author author author |
| dc.subject.none.fl_str_mv |
Implants dentals intraossis Cirurgia dental Endosseous dental implants Dental surgery |
| topic |
Implants dentals intraossis Cirurgia dental Endosseous dental implants Dental surgery |
| description |
Background: To assess the effect of implantoplasty and implant-abutment design on the fracture resistance and macroscopic morphology of narrow-diameter (3.5 mm) dental implants. Material and Methods: Screw-shaped titanium dental implants (n = 48) were studied in vitro. Three groups (n = 16) were established, based on implant-abutment connection type: external hexagon, internal hexagon and conical. Eight implants from each group were subjected to an implantoplasty procedure; the remaining 8 implants served as controls. Implant wall thickness was recorded. All samples were subjected to a static strength test. Results: The mean wall thickness reductions varied between 106.46 and 153.75 gm. The mean fracture strengths for the control and test groups were, respectively, 1211.90 +/- 89.95 N and 873.11 +/- 92.37 N in the external hexagon implants; 918.41 +/- 97.19 N and 661.29 +/- 58.03 N in the internal hexagon implants; and 1058.67 +/- 114.05 N and 747.32 +/- 90.05 N in the conical connection implants. Implant wall thickness and fracture resistance (P < 0.001) showed a positive correlation. Fracture strength was influenced by both implantoplasty (P < 0.001) and connection type (P < 0.001). Conclusions: Implantoplasty in diameter-reduced implants decreases implant wall thickness and fracture resistance, and varies depending on the implant-abutment connection. Internal hexagon and conical connection implants seem to be more prone to fracture after implantoplasty. |
| publishDate |
2020 |
| dc.date.none.fl_str_mv |
2020 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
https://hdl.handle.net/2445/173493 |
| url |
https://hdl.handle.net/2445/173493 |
| dc.language.none.fl_str_mv |
Inglés |
| language_invalid_str_mv |
Inglés |
| dc.relation.none.fl_str_mv |
Reproducció del document publicat a: https://doi.org/10.4317/medoral.23700 Medicina Oral Patologia Oral y Cirugia Bucal, 2020, vol. 25, num. 5, p. e691-e699 https://doi.org/10.4317/medoral.23700 |
| dc.rights.none.fl_str_mv |
(c) Medicina Oral SL, 2020 info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
(c) Medicina Oral SL, 2020 |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
Medicina Oral SL |
| publisher.none.fl_str_mv |
Medicina Oral SL |
| dc.source.none.fl_str_mv |
Articles publicats en revistes (Institut d'lnvestigació Biomèdica de Bellvitge (IDIBELL)) reponame:Dipòsit Digital de la UB instname:Universidad de Barcelona |
| instname_str |
Universidad de Barcelona |
| reponame_str |
Dipòsit Digital de la UB |
| collection |
Dipòsit Digital de la UB |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869409041461018624 |
| score |
15.301603 |