Fracture resistance after implantoplasty in three implant-abutment connection designs

Background: To assess the effect of implantoplasty and implant-abutment design on the fracture resistance and macroscopic morphology of narrow-diameter (3.5 mm) dental implants. Material and Methods: Screw-shaped titanium dental implants (n = 48) were studied in vitro. Three groups (n = 16) were est...

ver descrição completa

Detalhes bibliográficos
Autores: Camps Font, Octavi, González-Barnadas, Albert, Mir Mari, Javier, Barbosa de Figueiredo, Rui Pedro, Gay Escoda, Cosme, Valmaseda Castellón, Eduardo
Formato: artículo
Estado:Versión publicada
Fecha de publicación:2020
País:España
Recursos:Universidad de Barcelona
Repositorio:Dipòsit Digital de la UB
OAI Identifier:oai:diposit.ub.edu:2445/173493
Acesso em linha:https://hdl.handle.net/2445/173493
Access Level:acceso abierto
Palavra-chave:Implants dentals intraossis
Cirurgia dental
Endosseous dental implants
Dental surgery
id ES_5da12ff106be9e466d4e50f1a1bcca2b
oai_identifier_str oai:diposit.ub.edu:2445/173493
network_acronym_str ES
network_name_str España
repository_id_str
spelling Fracture resistance after implantoplasty in three implant-abutment connection designsCamps Font, OctaviGonzález-Barnadas, AlbertMir Mari, JavierBarbosa de Figueiredo, Rui PedroGay Escoda, CosmeValmaseda Castellón, EduardoImplants dentals intraossisCirurgia dentalEndosseous dental implantsDental surgeryBackground: To assess the effect of implantoplasty and implant-abutment design on the fracture resistance and macroscopic morphology of narrow-diameter (3.5 mm) dental implants. Material and Methods: Screw-shaped titanium dental implants (n = 48) were studied in vitro. Three groups (n = 16) were established, based on implant-abutment connection type: external hexagon, internal hexagon and conical. Eight implants from each group were subjected to an implantoplasty procedure; the remaining 8 implants served as controls. Implant wall thickness was recorded. All samples were subjected to a static strength test. Results: The mean wall thickness reductions varied between 106.46 and 153.75 gm. The mean fracture strengths for the control and test groups were, respectively, 1211.90 +/- 89.95 N and 873.11 +/- 92.37 N in the external hexagon implants; 918.41 +/- 97.19 N and 661.29 +/- 58.03 N in the internal hexagon implants; and 1058.67 +/- 114.05 N and 747.32 +/- 90.05 N in the conical connection implants. Implant wall thickness and fracture resistance (P < 0.001) showed a positive correlation. Fracture strength was influenced by both implantoplasty (P < 0.001) and connection type (P < 0.001). Conclusions: Implantoplasty in diameter-reduced implants decreases implant wall thickness and fracture resistance, and varies depending on the implant-abutment connection. Internal hexagon and conical connection implants seem to be more prone to fracture after implantoplasty.Medicina Oral SL2020info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://hdl.handle.net/2445/173493Articles publicats en revistes (Institut d'lnvestigació Biomèdica de Bellvitge (IDIBELL))reponame:Dipòsit Digital de la UBinstname:Universidad de BarcelonaInglésReproducció del document publicat a: https://doi.org/10.4317/medoral.23700Medicina Oral Patologia Oral y Cirugia Bucal, 2020, vol. 25, num. 5, p. e691-e699https://doi.org/10.4317/medoral.23700(c) Medicina Oral SL, 2020info:eu-repo/semantics/openAccessoai:diposit.ub.edu:2445/1734932026-05-27T06:46:51Z
dc.title.none.fl_str_mv Fracture resistance after implantoplasty in three implant-abutment connection designs
title Fracture resistance after implantoplasty in three implant-abutment connection designs
spellingShingle Fracture resistance after implantoplasty in three implant-abutment connection designs
Camps Font, Octavi
Implants dentals intraossis
Cirurgia dental
Endosseous dental implants
Dental surgery
title_short Fracture resistance after implantoplasty in three implant-abutment connection designs
title_full Fracture resistance after implantoplasty in three implant-abutment connection designs
title_fullStr Fracture resistance after implantoplasty in three implant-abutment connection designs
title_full_unstemmed Fracture resistance after implantoplasty in three implant-abutment connection designs
title_sort Fracture resistance after implantoplasty in three implant-abutment connection designs
dc.creator.none.fl_str_mv Camps Font, Octavi
González-Barnadas, Albert
Mir Mari, Javier
Barbosa de Figueiredo, Rui Pedro
Gay Escoda, Cosme
Valmaseda Castellón, Eduardo
author Camps Font, Octavi
author_facet Camps Font, Octavi
González-Barnadas, Albert
Mir Mari, Javier
Barbosa de Figueiredo, Rui Pedro
Gay Escoda, Cosme
Valmaseda Castellón, Eduardo
author_role author
author2 González-Barnadas, Albert
Mir Mari, Javier
Barbosa de Figueiredo, Rui Pedro
Gay Escoda, Cosme
Valmaseda Castellón, Eduardo
author2_role author
author
author
author
author
dc.subject.none.fl_str_mv Implants dentals intraossis
Cirurgia dental
Endosseous dental implants
Dental surgery
topic Implants dentals intraossis
Cirurgia dental
Endosseous dental implants
Dental surgery
description Background: To assess the effect of implantoplasty and implant-abutment design on the fracture resistance and macroscopic morphology of narrow-diameter (3.5 mm) dental implants. Material and Methods: Screw-shaped titanium dental implants (n = 48) were studied in vitro. Three groups (n = 16) were established, based on implant-abutment connection type: external hexagon, internal hexagon and conical. Eight implants from each group were subjected to an implantoplasty procedure; the remaining 8 implants served as controls. Implant wall thickness was recorded. All samples were subjected to a static strength test. Results: The mean wall thickness reductions varied between 106.46 and 153.75 gm. The mean fracture strengths for the control and test groups were, respectively, 1211.90 +/- 89.95 N and 873.11 +/- 92.37 N in the external hexagon implants; 918.41 +/- 97.19 N and 661.29 +/- 58.03 N in the internal hexagon implants; and 1058.67 +/- 114.05 N and 747.32 +/- 90.05 N in the conical connection implants. Implant wall thickness and fracture resistance (P < 0.001) showed a positive correlation. Fracture strength was influenced by both implantoplasty (P < 0.001) and connection type (P < 0.001). Conclusions: Implantoplasty in diameter-reduced implants decreases implant wall thickness and fracture resistance, and varies depending on the implant-abutment connection. Internal hexagon and conical connection implants seem to be more prone to fracture after implantoplasty.
publishDate 2020
dc.date.none.fl_str_mv 2020
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://hdl.handle.net/2445/173493
url https://hdl.handle.net/2445/173493
dc.language.none.fl_str_mv Inglés
language_invalid_str_mv Inglés
dc.relation.none.fl_str_mv Reproducció del document publicat a: https://doi.org/10.4317/medoral.23700
Medicina Oral Patologia Oral y Cirugia Bucal, 2020, vol. 25, num. 5, p. e691-e699
https://doi.org/10.4317/medoral.23700
dc.rights.none.fl_str_mv (c) Medicina Oral SL, 2020
info:eu-repo/semantics/openAccess
rights_invalid_str_mv (c) Medicina Oral SL, 2020
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Medicina Oral SL
publisher.none.fl_str_mv Medicina Oral SL
dc.source.none.fl_str_mv Articles publicats en revistes (Institut d'lnvestigació Biomèdica de Bellvitge (IDIBELL))
reponame:Dipòsit Digital de la UB
instname:Universidad de Barcelona
instname_str Universidad de Barcelona
reponame_str Dipòsit Digital de la UB
collection Dipòsit Digital de la UB
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869409041461018624
score 15.301603