Porous Structure of Ultra-High-Performance Fibre-Reinforced Concretes
[EN] The aim of this experimental work was to study the porous structure of Ultra-High-Performance Fibre-Reinforced Concretes (UH) made with different fibre volume contents (0%, 1%, 2%) under several curing conditions (laboratory environment, 20 degrees C, 60 degrees C, 90 degrees C), comparing the...
| Autores: | , , , |
|---|---|
| Tipo de recurso: | artículo |
| Fecha de publicación: | 2021 |
| País: | España |
| Institución: | Universitat Politècnica de València (UPV) |
| Repositorio: | RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia |
| Idioma: | inglés |
| OAI Identifier: | oai:riunet.upv.es:10251/180038 |
| Acceso en línea: | https://riunet.upv.es/handle/10251/180038 |
| Access Level: | acceso abierto |
| Palabra clave: | Ultra-high-performance fibre-reinforced concrete Porosity Water porosity Oxygen permeability CONSTRUCCIONES ARQUITECTONICAS |
| id |
ES_5cf4e5d773247d96247a4b02446a14fb |
|---|---|
| oai_identifier_str |
oai:riunet.upv.es:10251/180038 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Porous Structure of Ultra-High-Performance Fibre-Reinforced ConcretesValcuende Payá, Manuel Octavio|||0000-0002-9967-1554Lliso-Ferrando, Josep Ramon|||0000-0002-2457-9024Gandía-Romero, Jose M.|||0000-0003-0257-3286Roig-Flores, MartaUltra-high-performance fibre-reinforced concretePorosityWater porosityOxygen permeabilityCONSTRUCCIONES ARQUITECTONICAS[EN] The aim of this experimental work was to study the porous structure of Ultra-High-Performance Fibre-Reinforced Concretes (UH) made with different fibre volume contents (0%, 1%, 2%) under several curing conditions (laboratory environment, 20 degrees C, 60 degrees C, 90 degrees C), comparing the results with those recorded for ordinary, high strength and very high strength concretes. Scanning electron microscopy, mercury intrusion porosimetry, thermogravimetry, water absorption and oxygen permeability tests were carried out. The results showed a low portlandite content in UH (in the order of 75% lower than in concrete C50) and a low degree of hydration, but they rise with curing temperature. These concretes have a very fine porous structure, with a high concentration of pores on the nanoscale level, below 0.05 mu m. Their porosity accessible to water is consequently around 7-fold lower than in conventional (C30), 6-fold lower than in high-strength (C50) and 4-fold lower than in very high-strength (C90) concretes. Their oxygen permeability is at least one order of magnitude lower than in C90, two orders of magnitude lower than in C50 and three orders of magnitude lower than in C30. The percentage of added steel fibre does not affect the UH porous structureThis research was funded by Ministerio de Economia Y Competitividad (Agencia Estatal de Investigacion) of the Spanish Government, Grant number BIA2016-78460-C3-3-RMDPI AGDepartamento de Construcciones ArquitectónicasEscuela Técnica Superior de ArquitecturaEscuela Técnica Superior de Ingeniería de EdificaciónInstituto Interuniversitario de Investigación de Reconocimiento Molecular y Desarrollo TecnológicoCentro de Investigación de Tecnología de la EdificaciónAGENCIA ESTATAL DE INVESTIGACIONRepositorio Institucional de la Universitat Politècnica de València Riunet20212021-04-01journal articlehttp://purl.org/coar/resource_type/c_6501VoRhttp://purl.org/coar/version/c_970fb48d4fbd8a85info:eu-repo/semantics/articleapplication/pdfhttps://riunet.upv.es/handle/10251/180038reponame:RiuNet. Repositorio Institucional de la Universitat Politécnica de Valénciainstname:Universitat Politècnica de València (UPV)InglésengAgencia Estatal de Investigación http://dx.doi.org/10.13039/501100011033 BIA2016-78460-C3-3-R DURABILIDAD Y VIDA UTIL DEL HORMIGON DE MUY ALTO RENDIMIENTOopen accesshttp://purl.org/coar/access_right/c_abf2Reconocimiento (by)http://creativecommons.org/licenses/by/4.0/info:eu-repo/semantics/openAccessoai:riunet.upv.es:10251/1800382026-06-13T07:49:27Z |
| dc.title.none.fl_str_mv |
Porous Structure of Ultra-High-Performance Fibre-Reinforced Concretes |
| title |
Porous Structure of Ultra-High-Performance Fibre-Reinforced Concretes |
| spellingShingle |
Porous Structure of Ultra-High-Performance Fibre-Reinforced Concretes Valcuende Payá, Manuel Octavio|||0000-0002-9967-1554 Ultra-high-performance fibre-reinforced concrete Porosity Water porosity Oxygen permeability CONSTRUCCIONES ARQUITECTONICAS |
| title_short |
Porous Structure of Ultra-High-Performance Fibre-Reinforced Concretes |
| title_full |
Porous Structure of Ultra-High-Performance Fibre-Reinforced Concretes |
| title_fullStr |
Porous Structure of Ultra-High-Performance Fibre-Reinforced Concretes |
| title_full_unstemmed |
Porous Structure of Ultra-High-Performance Fibre-Reinforced Concretes |
| title_sort |
Porous Structure of Ultra-High-Performance Fibre-Reinforced Concretes |
| dc.creator.none.fl_str_mv |
Valcuende Payá, Manuel Octavio|||0000-0002-9967-1554 Lliso-Ferrando, Josep Ramon|||0000-0002-2457-9024 Gandía-Romero, Jose M.|||0000-0003-0257-3286 Roig-Flores, Marta |
| author |
Valcuende Payá, Manuel Octavio|||0000-0002-9967-1554 |
| author_facet |
Valcuende Payá, Manuel Octavio|||0000-0002-9967-1554 Lliso-Ferrando, Josep Ramon|||0000-0002-2457-9024 Gandía-Romero, Jose M.|||0000-0003-0257-3286 Roig-Flores, Marta |
| author_role |
author |
| author2 |
Lliso-Ferrando, Josep Ramon|||0000-0002-2457-9024 Gandía-Romero, Jose M.|||0000-0003-0257-3286 Roig-Flores, Marta |
| author2_role |
author author author |
| dc.contributor.none.fl_str_mv |
Departamento de Construcciones Arquitectónicas Escuela Técnica Superior de Arquitectura Escuela Técnica Superior de Ingeniería de Edificación Instituto Interuniversitario de Investigación de Reconocimiento Molecular y Desarrollo Tecnológico Centro de Investigación de Tecnología de la Edificación AGENCIA ESTATAL DE INVESTIGACION Repositorio Institucional de la Universitat Politècnica de València Riunet |
| dc.subject.none.fl_str_mv |
Ultra-high-performance fibre-reinforced concrete Porosity Water porosity Oxygen permeability CONSTRUCCIONES ARQUITECTONICAS |
| topic |
Ultra-high-performance fibre-reinforced concrete Porosity Water porosity Oxygen permeability CONSTRUCCIONES ARQUITECTONICAS |
| description |
[EN] The aim of this experimental work was to study the porous structure of Ultra-High-Performance Fibre-Reinforced Concretes (UH) made with different fibre volume contents (0%, 1%, 2%) under several curing conditions (laboratory environment, 20 degrees C, 60 degrees C, 90 degrees C), comparing the results with those recorded for ordinary, high strength and very high strength concretes. Scanning electron microscopy, mercury intrusion porosimetry, thermogravimetry, water absorption and oxygen permeability tests were carried out. The results showed a low portlandite content in UH (in the order of 75% lower than in concrete C50) and a low degree of hydration, but they rise with curing temperature. These concretes have a very fine porous structure, with a high concentration of pores on the nanoscale level, below 0.05 mu m. Their porosity accessible to water is consequently around 7-fold lower than in conventional (C30), 6-fold lower than in high-strength (C50) and 4-fold lower than in very high-strength (C90) concretes. Their oxygen permeability is at least one order of magnitude lower than in C90, two orders of magnitude lower than in C50 and three orders of magnitude lower than in C30. The percentage of added steel fibre does not affect the UH porous structure |
| publishDate |
2021 |
| dc.date.none.fl_str_mv |
2021 2021-04-01 |
| dc.type.none.fl_str_mv |
journal article http://purl.org/coar/resource_type/c_6501 VoR http://purl.org/coar/version/c_970fb48d4fbd8a85 |
| dc.type.openaire.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| dc.identifier.none.fl_str_mv |
https://riunet.upv.es/handle/10251/180038 |
| url |
https://riunet.upv.es/handle/10251/180038 |
| dc.language.none.fl_str_mv |
Inglés eng |
| language_invalid_str_mv |
Inglés |
| language |
eng |
| dc.relation.none.fl_str_mv |
Agencia Estatal de Investigación http://dx.doi.org/10.13039/501100011033 BIA2016-78460-C3-3-R DURABILIDAD Y VIDA UTIL DEL HORMIGON DE MUY ALTO RENDIMIENTO |
| dc.rights.none.fl_str_mv |
open access http://purl.org/coar/access_right/c_abf2 Reconocimiento (by) http://creativecommons.org/licenses/by/4.0/ |
| dc.rights.openaire.fl_str_mv |
info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
open access http://purl.org/coar/access_right/c_abf2 Reconocimiento (by) http://creativecommons.org/licenses/by/4.0/ |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
MDPI AG |
| publisher.none.fl_str_mv |
MDPI AG |
| dc.source.none.fl_str_mv |
reponame:RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia instname:Universitat Politècnica de València (UPV) |
| instname_str |
Universitat Politècnica de València (UPV) |
| reponame_str |
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia |
| collection |
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869408966484688896 |
| score |
15.300724 |