On the Move-Sensitive Fluorescent Aptassay on Board Catalytic Micromotors for the Determination of Interleukin-6 in Ultra-Low Serum Volumes for Neonatal Sepsis Diagnostics

A graphene oxide/nickel/platinum nanoparticle micromotor (MM)-based fluorescent aptassay is proposed to determine interleukin-6 (IL-6) in serum samples from low-birth-weight infants (gestational age of less than 32 weeks and birthweight below 1000 g) with sepsis suspicion. In this kind of patients,...

Descripción completa

Detalles Bibliográficos
Autores: Gordón Pidal, José María|||0000-0001-8465-3268, Arruza Gómez, Luis, Ibáñez, María Dolores, Moreno Guzmán, María, López Gil, Miguel Ángel|||0000-0003-3711-010X, Escarpa Miguel, Jesús Alberto|||0000-0002-7302-0948
Tipo de recurso: artículo
Fecha de publicación:2022
País:España
Institución:Universidad de Alcalá (UAH)
Repositorio:e_Buah Biblioteca Digital Universidad de Alcalá
Idioma:inglés
OAI Identifier:oai:ebuah.uah.es:10017/59726
Acceso en línea:http://hdl.handle.net/10017/59726
https://dx.doi.org/10.1021/acssensors.2c01635
Access Level:acceso abierto
Palabra clave:micromotors
on-the-move aptassay
graphene
fluorescence microscopy
interleukin-6neonate sepsis
Química
Chemistry
Descripción
Sumario:A graphene oxide/nickel/platinum nanoparticle micromotor (MM)-based fluorescent aptassay is proposed to determine interleukin-6 (IL-6) in serum samples from low-birth-weight infants (gestational age of less than 32 weeks and birthweight below 1000 g) with sepsis suspicion. In this kind of patients, IL-6 has demonstrated good sensitivity and specificity for the diagnosis of sepsis, both for early and late onset sepsis. The approach was based on the adsorption of the aptamer for IL-6 tagged with 6-FAM as a fluorescent label (AptIL?6, ?em = 520 nm) on the graphene oxide external layer (MMGO?AptIL?6) inducing fluorescence quenching (OFF state) and a subsequent on-the-move affinity recognition of IL-6 from AptIL?6 (IL-6?AptIL?6 complex) recovering the fluorescence (ON state). An aptamer against IL-6 was selected and developed by the systematic evolution of ligands by exponential enrichment technology. This approach displayed a suitable linear range of 0.07?1000 pg mL?1 (r = 0.995) covering the cut-off and clinical practice levels, allowing direct determination without any dilution and simplifying the analysis as well as exhibiting an excellent sensitivity (LOD = 0.02 pg mL?1) in ultralow volumes of diagnostic clinical samples (2 ?L). A high agreement between IL-6 levels obtained from our MM-based approach and the method used by the Hospital was obtained (relative error < 3%). The MM-based aptassay is competitive in comparison with that of the Hospital, in terms of a significant reduction of the sample volume (15 times less) and enhanced sensitivity, employing similar analysis times. These results position MM technology with enough potential to achieve high sensitivities in low sample volumes, opening new avenues in diagnosis based on low sample volumes.