Evaluation of Sweat-Sampling Procedures for Human Stress-Biomarker Detection
Sweat is a potential biological fluid for the non-invasive analytical assessment of diverse molecules, including biomarkers. Notwithstanding, the sampling methodology is critical, and it must be assessed prior to using sweat for clinical diagnosis. In the current work, the analytical methodology was...
| Autores: | , , , , , , , |
|---|---|
| Tipo de recurso: | artículo |
| Fecha de publicación: | 2022 |
| País: | España |
| Institución: | Universidad Autónoma de Madrid |
| Repositorio: | Biblos-e Archivo. Repositorio Institucional de la UAM |
| Idioma: | inglés |
| OAI Identifier: | oai:repositorio.uam.es:10486/713656 |
| Acceso en línea: | http://hdl.handle.net/10486/713656 https://dx.doi.org/10.3390/analytica3020013 |
| Access Level: | acceso abierto |
| Palabra clave: | biomarkers blood analysis LC-MS/MS sampling stress sweat Medicina |
| id |
ES_5bc23b0e63f554c22b60a6a8dbd44369 |
|---|---|
| oai_identifier_str |
oai:repositorio.uam.es:10486/713656 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Evaluation of Sweat-Sampling Procedures for Human Stress-Biomarker DetectionNunes, Maria JoãoMoura, José J.G.Noronha, João PauloBranco, Luís CobraSamhan Arias, Alejandro KhalilSousa, João P.Rouco, CarlosCordas, Cristina M.biomarkersblood analysisLC-MS/MSsamplingstresssweatMedicinaSweat is a potential biological fluid for the non-invasive analytical assessment of diverse molecules, including biomarkers. Notwithstanding, the sampling methodology is critical, and it must be assessed prior to using sweat for clinical diagnosis. In the current work, the analytical methodology was further developed taking into account the sampling step, in view of the identification and level variations of sweat components that have potential to be stress biomarkers using separation by liquid chromatography and detection by tandem mass spectrometry, in order to attain a screening profile of 26 molecules in just one stage. As such, the molecule identification was used as a test for the evaluation of the sampling procedures, including the location on the body, using patches for long-term sampling and vials for direct sampling, through a qualitative approach. From this evaluation it was possible to conclude that the sampling may be performed on the chest or back skin. Additionally, possible interference was evaluated. The long-term sampling with patches can be used under both rest and exercise conditions with variation of the detected molecule’s levels. The direct sampling, using vials, has the advantage of not having interferences but the disadvantage of only being effective after exercise in order to have enough sample for sweat analysisMDPIDepartamento de BioquímicaFacultad de Medicina20222022-04-16research articlehttp://purl.org/coar/resource_type/c_2df8fbb1VoRhttp://purl.org/coar/version/c_970fb48d4fbd8a85info:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10486/713656https://dx.doi.org/10.3390/analytica3020013reponame:Biblos-e Archivo. Repositorio Institucional de la UAMinstname:Universidad Autónoma de MadridInglésengopen accesshttp://purl.org/coar/access_right/c_abf2Attribution 4.0 Internationalhttp://creativecommons.org/licenses/by/4.0/info:eu-repo/semantics/openAccessoai:repositorio.uam.es:10486/7136562026-06-23T12:46:27Z |
| dc.title.none.fl_str_mv |
Evaluation of Sweat-Sampling Procedures for Human Stress-Biomarker Detection |
| title |
Evaluation of Sweat-Sampling Procedures for Human Stress-Biomarker Detection |
| spellingShingle |
Evaluation of Sweat-Sampling Procedures for Human Stress-Biomarker Detection Nunes, Maria João biomarkers blood analysis LC-MS/MS sampling stress sweat Medicina |
| title_short |
Evaluation of Sweat-Sampling Procedures for Human Stress-Biomarker Detection |
| title_full |
Evaluation of Sweat-Sampling Procedures for Human Stress-Biomarker Detection |
| title_fullStr |
Evaluation of Sweat-Sampling Procedures for Human Stress-Biomarker Detection |
| title_full_unstemmed |
Evaluation of Sweat-Sampling Procedures for Human Stress-Biomarker Detection |
| title_sort |
Evaluation of Sweat-Sampling Procedures for Human Stress-Biomarker Detection |
| dc.creator.none.fl_str_mv |
Nunes, Maria João Moura, José J.G. Noronha, João Paulo Branco, Luís Cobra Samhan Arias, Alejandro Khalil Sousa, João P. Rouco, Carlos Cordas, Cristina M. |
| author |
Nunes, Maria João |
| author_facet |
Nunes, Maria João Moura, José J.G. Noronha, João Paulo Branco, Luís Cobra Samhan Arias, Alejandro Khalil Sousa, João P. Rouco, Carlos Cordas, Cristina M. |
| author_role |
author |
| author2 |
Moura, José J.G. Noronha, João Paulo Branco, Luís Cobra Samhan Arias, Alejandro Khalil Sousa, João P. Rouco, Carlos Cordas, Cristina M. |
| author2_role |
author author author author author author author |
| dc.contributor.none.fl_str_mv |
Departamento de Bioquímica Facultad de Medicina |
| dc.subject.none.fl_str_mv |
biomarkers blood analysis LC-MS/MS sampling stress sweat Medicina |
| topic |
biomarkers blood analysis LC-MS/MS sampling stress sweat Medicina |
| description |
Sweat is a potential biological fluid for the non-invasive analytical assessment of diverse molecules, including biomarkers. Notwithstanding, the sampling methodology is critical, and it must be assessed prior to using sweat for clinical diagnosis. In the current work, the analytical methodology was further developed taking into account the sampling step, in view of the identification and level variations of sweat components that have potential to be stress biomarkers using separation by liquid chromatography and detection by tandem mass spectrometry, in order to attain a screening profile of 26 molecules in just one stage. As such, the molecule identification was used as a test for the evaluation of the sampling procedures, including the location on the body, using patches for long-term sampling and vials for direct sampling, through a qualitative approach. From this evaluation it was possible to conclude that the sampling may be performed on the chest or back skin. Additionally, possible interference was evaluated. The long-term sampling with patches can be used under both rest and exercise conditions with variation of the detected molecule’s levels. The direct sampling, using vials, has the advantage of not having interferences but the disadvantage of only being effective after exercise in order to have enough sample for sweat analysis |
| publishDate |
2022 |
| dc.date.none.fl_str_mv |
2022 2022-04-16 |
| dc.type.none.fl_str_mv |
research article http://purl.org/coar/resource_type/c_2df8fbb1 VoR http://purl.org/coar/version/c_970fb48d4fbd8a85 |
| dc.type.openaire.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| dc.identifier.none.fl_str_mv |
http://hdl.handle.net/10486/713656 https://dx.doi.org/10.3390/analytica3020013 |
| url |
http://hdl.handle.net/10486/713656 https://dx.doi.org/10.3390/analytica3020013 |
| dc.language.none.fl_str_mv |
Inglés eng |
| language_invalid_str_mv |
Inglés |
| language |
eng |
| dc.rights.none.fl_str_mv |
open access http://purl.org/coar/access_right/c_abf2 Attribution 4.0 International http://creativecommons.org/licenses/by/4.0/ |
| dc.rights.openaire.fl_str_mv |
info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
open access http://purl.org/coar/access_right/c_abf2 Attribution 4.0 International http://creativecommons.org/licenses/by/4.0/ |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
MDPI |
| publisher.none.fl_str_mv |
MDPI |
| dc.source.none.fl_str_mv |
reponame:Biblos-e Archivo. Repositorio Institucional de la UAM instname:Universidad Autónoma de Madrid |
| instname_str |
Universidad Autónoma de Madrid |
| reponame_str |
Biblos-e Archivo. Repositorio Institucional de la UAM |
| collection |
Biblos-e Archivo. Repositorio Institucional de la UAM |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869408826308952064 |
| score |
15.812455 |