Portable Liquid Chromatography

[EN]The development of miniaturized systems has opened the possibility of the introduction of hand-portable liquid chromatography (LC), but LC has evolved slowly although it has significant potential for solving analytical challenges in various applications in situ or at-situ monitoring, due to thei...

Descripción completa

Detalles Bibliográficos
Autores: Cortés-Bautista, Sergio, Campíns-Falcó, Pilar
Tipo de recurso: artículo
Estado:Versión aceptada para publicación
Fecha de publicación:2023
País:España
Institución:Universidad de Salamanca (USAL)
Repositorio:GREDOS. Repositorio Institucional de la Universidad de Salamanca
OAI Identifier:oai:gredos.usal.es:10366/169295
Acceso en línea:http://hdl.handle.net/10366/169295
Access Level:acceso embargado
Palabra clave:Portable liquid chromatography
Miniaturization
Fiel instriumentation
Nano-LC
Capillary LC
2301 Química Analítica
id ES_58e1745f326e3473fda7edb40614ee80
oai_identifier_str oai:gredos.usal.es:10366/169295
network_acronym_str ES
network_name_str España
repository_id_str
spelling Portable Liquid ChromatographyCortés-Bautista, SergioCampíns-Falcó, PilarPortable liquid chromatographyMiniaturizationFiel instriumentationNano-LCCapillary LC2301 Química Analítica[EN]The development of miniaturized systems has opened the possibility of the introduction of hand-portable liquid chromatography (LC), but LC has evolved slowly although it has significant potential for solving analytical challenges in various applications in situ or at-situ monitoring, due to their ability to perform measurements at the point of the potential analytical problem occurs. This chapter provides an overview of the current state of the art of portable LC technology and its context. The first LC reported as portable was the OB-4 or Milichrom, developed by Baram et al. in 1983, but this system is far away from the contemporary idea of portability although served as a basis for the later developed portable LCs. It was not until 2015, with notable advancements in pump, detectors, column technology, and batteries that a new wave of portable LCs emerged. A timeline with relevant portable LC contributions is given and their main features are described along the chapter. The Axcend Focus was the first commercialized capillary/nano portable LC. Sharma et al. in 2015 proposed a number of requirements that a LC system must achieve to be considered as portable and Rahimi et al. in 2020 developed a criteria to assess LC portability named BETTER criteria (portaBle fiEld Testing sTandard framework), which evaluates: the system cost, performance, robustness, operation time, portability, and weight. To date, portable LC systems meet some of the grade 2 and 3 criteria for almost all assessments. The grade 4 and 5 criteria are deemed a challenge to be met by next generation devices. Several studies have tested the capabilities of different pumping systems, with syringe pumps being the most popular options.Injectors have not presented a major obstacle when they come to adapting to portable equipment. The downscaling of LC has been closely related to the dimensions of the analytical column, particularly to its internal diameter, capillary packed and monolithic columns have been employed. On-column LED detection configurations, which do not make use of flow-cells eliminating the associated dead volumes were proposed. Electrochemical detectors were also used in portable LC. In the case of almost all portable LCs, which were homemade and were not commercialized, only one work for the most of them was published and then the number of real applications is scarce. New knowledge is necessary for advancing in portable LC.John Wiley & Sonsinfo202620262023info:eu-repo/semantics/articleinfo:eu-repo/semantics/acceptedVersionhttp://hdl.handle.net/10366/169295reponame:GREDOS. Repositorio Institucional de la Universidad de Salamancainstname:Universidad de Salamanca (USAL)InglésAttribution-NonCommercial-NoDerivatives 4.0 Internacionalhttp://creativecommons.org/licenses/by-nc-nd/4.0/info:eu-repo/semantics/embargoedAccessoai:gredos.usal.es:10366/1692952026-06-07T06:28:51Z
dc.title.none.fl_str_mv Portable Liquid Chromatography
title Portable Liquid Chromatography
spellingShingle Portable Liquid Chromatography
Cortés-Bautista, Sergio
Portable liquid chromatography
Miniaturization
Fiel instriumentation
Nano-LC
Capillary LC
2301 Química Analítica
title_short Portable Liquid Chromatography
title_full Portable Liquid Chromatography
title_fullStr Portable Liquid Chromatography
title_full_unstemmed Portable Liquid Chromatography
title_sort Portable Liquid Chromatography
dc.creator.none.fl_str_mv Cortés-Bautista, Sergio
Campíns-Falcó, Pilar
author Cortés-Bautista, Sergio
author_facet Cortés-Bautista, Sergio
Campíns-Falcó, Pilar
author_role author
author2 Campíns-Falcó, Pilar
author2_role author
dc.subject.none.fl_str_mv Portable liquid chromatography
Miniaturization
Fiel instriumentation
Nano-LC
Capillary LC
2301 Química Analítica
topic Portable liquid chromatography
Miniaturization
Fiel instriumentation
Nano-LC
Capillary LC
2301 Química Analítica
description [EN]The development of miniaturized systems has opened the possibility of the introduction of hand-portable liquid chromatography (LC), but LC has evolved slowly although it has significant potential for solving analytical challenges in various applications in situ or at-situ monitoring, due to their ability to perform measurements at the point of the potential analytical problem occurs. This chapter provides an overview of the current state of the art of portable LC technology and its context. The first LC reported as portable was the OB-4 or Milichrom, developed by Baram et al. in 1983, but this system is far away from the contemporary idea of portability although served as a basis for the later developed portable LCs. It was not until 2015, with notable advancements in pump, detectors, column technology, and batteries that a new wave of portable LCs emerged. A timeline with relevant portable LC contributions is given and their main features are described along the chapter. The Axcend Focus was the first commercialized capillary/nano portable LC. Sharma et al. in 2015 proposed a number of requirements that a LC system must achieve to be considered as portable and Rahimi et al. in 2020 developed a criteria to assess LC portability named BETTER criteria (portaBle fiEld Testing sTandard framework), which evaluates: the system cost, performance, robustness, operation time, portability, and weight. To date, portable LC systems meet some of the grade 2 and 3 criteria for almost all assessments. The grade 4 and 5 criteria are deemed a challenge to be met by next generation devices. Several studies have tested the capabilities of different pumping systems, with syringe pumps being the most popular options.Injectors have not presented a major obstacle when they come to adapting to portable equipment. The downscaling of LC has been closely related to the dimensions of the analytical column, particularly to its internal diameter, capillary packed and monolithic columns have been employed. On-column LED detection configurations, which do not make use of flow-cells eliminating the associated dead volumes were proposed. Electrochemical detectors were also used in portable LC. In the case of almost all portable LCs, which were homemade and were not commercialized, only one work for the most of them was published and then the number of real applications is scarce. New knowledge is necessary for advancing in portable LC.
publishDate 2023
dc.date.none.fl_str_mv 2023
2026
2026
info
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/acceptedVersion
format article
status_str acceptedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/10366/169295
url http://hdl.handle.net/10366/169295
dc.language.none.fl_str_mv Inglés
language_invalid_str_mv Inglés
dc.rights.none.fl_str_mv Attribution-NonCommercial-NoDerivatives 4.0 Internacional
http://creativecommons.org/licenses/by-nc-nd/4.0/
info:eu-repo/semantics/embargoedAccess
rights_invalid_str_mv Attribution-NonCommercial-NoDerivatives 4.0 Internacional
http://creativecommons.org/licenses/by-nc-nd/4.0/
eu_rights_str_mv embargoedAccess
dc.publisher.none.fl_str_mv John Wiley & Sons
publisher.none.fl_str_mv John Wiley & Sons
dc.source.none.fl_str_mv reponame:GREDOS. Repositorio Institucional de la Universidad de Salamanca
instname:Universidad de Salamanca (USAL)
instname_str Universidad de Salamanca (USAL)
reponame_str GREDOS. Repositorio Institucional de la Universidad de Salamanca
collection GREDOS. Repositorio Institucional de la Universidad de Salamanca
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869408574652809216
score 15,811543