Operation of HVDC converters for transformer inrush current reduction

The present PhD thesis deals with transformer inrush current in offshore grids including offshore wind farms and High Voltage Direct Current (HVDC) transmission systems. The inrush phenomenon during transformers energization or recovery after the fault clearance is one of important concerns in offsh...

Descripción completa

Detalles Bibliográficos
Autor: Solh Joukhah, Zahra
Tipo de recurso: tesis doctoral
Estado:Versión publicada
Fecha de publicación:2017
País:España
Institución:CBUC, CESCA
Repositorio:TDR. Tesis Doctorales en Red
OAI Identifier:oai:www.tdx.cat:10803/461569
Acceso en línea:http://hdl.handle.net/10803/461569
https://dx.doi.org/10.5821/dissertation-2117-114603
Access Level:acceso abierto
Palabra clave:Àrees temàtiques de la UPC::Enginyeria elèctrica
537
621.3
Descripción
Sumario:The present PhD thesis deals with transformer inrush current in offshore grids including offshore wind farms and High Voltage Direct Current (HVDC) transmission systems. The inrush phenomenon during transformers energization or recovery after the fault clearance is one of important concerns in offshore systems which can threaten the security and reliability of the HVDC grid operation as well as the wind farms function. Hence, the behaviour of wind turbines,Voltage Source Converters (VSC) and transformer under the normal operation and the inrush transient mode is analyzed. For inrush current reduction in the procedure of the offshore wind farms start-up and integration into the onshore AC grid, a technique based on Voltage Ramping Strategy (VRS) is proposed and its performance is compared with the operation of system without consideration of this approach. The new methodology which is simple, cost-effective ensures minimization of transformer inrush current in the offshore systems and the enhancement of power quality and the reliability of grid under the transformer energizing condition. The mentioned method can develop much lower inrush currents according to the slower voltage ramp slopes. Concerning the recovery inrush current, the operation of the offshore grid especially transformers is analyzed under the fault and the system restoration modes.The recovery inrush transient of transformers can cause tripping the HVDC and wind farms converters as well as disturbing the HVDC power transmission. A voltage control design based on VRS is proposed in HVDC converter to recover ali the transformers in offshore grid with lower inrush currents.The control system proposed can assure the correct performance of the converters in HVDC system and in wind farm and also the robust stability of the offshore grid.