External validation of a non-invasive vaginal tool to assess the risk of intra-amniotic inflammation in pregnant women with preterm labor and intact membranes.
OBJECTIVES: To prospectively validate the diagnostic performance of a non-invasive point-of-care tool (Rapid IAI System), including vaginal alpha-fetoprotein and interleukin-6, to predict the occurrence of intra-amniotic inflammation in a Spanish cohort of patients admitted with a diagnosis of prete...
| Autores: | , , , , , , , , , , , , |
|---|---|
| Tipo de recurso: | artículo |
| Estado: | Versión publicada |
| Fecha de publicación: | 2025 |
| País: | España |
| Institución: | Fundació Sant Joan de Déu |
| Repositorio: | r-FSJD. Repositorio Institucional de Producción Científica de la Fundació Sant Joan de Déu |
| OAI Identifier: | oai:fsjd.fundanetsuite.com:p27077 |
| Acceso en línea: | https://fsjd.fundanetsuite.com/Publicaciones/ProdCientif/PublicacionFrw.aspx?id=27077 |
| Access Level: | acceso abierto |
| Palabra clave: | intra-amniotic inflammation point-of-care prediction models preterm labor and intact membranes vaginal alpha-fetoprotein vaginal interleukin-6 |
| Sumario: | OBJECTIVES: To prospectively validate the diagnostic performance of a non-invasive point-of-care tool (Rapid IAI System), including vaginal alpha-fetoprotein and interleukin-6, to predict the occurrence of intra-amniotic inflammation in a Spanish cohort of patients admitted with a diagnosis of preterm labor and intact membranes. METHODS: From 2017 to 2022, we prospectively evaluated a cohort of pregnant women diagnosed with preterm labor and intact membranes admitted below 34+0 weeks who underwent amniocentesis to rule-in/out intra-amniotic infection and/or inflammation. Vaginal sampling was performed at the time of amniocentesis or within 24-48?h. Amniotic fluid IL-6, vaginal alpha-fetoprotein and vaginal IL-6 concentrations were measured using a point-of-care tool provided by Hologic Inc., "Rapid IAI System". We defined intra-amniotic inflammation when amniotic fluid IL-6 values were greater than 11.3?ng/mL. During recruitment, clinicians were blinded to the results of the point-of-care tool. The original prediction model proposed by Hologic Inc. to predict intra-amniotic inflammation was validated in this cohort of patients. RESULTS: We included 151 patients diagnosed with preterm labor and intact membranes. Among these, 29 (19.2?%) had intra-amniotic inflammation. The algorithm including vaginal IL-6 and alpha-fetoprotein showed an area under curve to predict intra-amniotic inflammation of 80.3?% (±5.3?%) with a sensitivity of 72.4?%, specificity of 84.6?%, positive predictive valuve (PPV) of 52.5?%, negative predictive value (NPV) of 92.9?%, and a positive likelihood ratio (LR+) of 4.6 and negative likelihood ratio (LR-) of 0.33. CONCLUSIONS: External validation of a non-invasive rapid point-of-care tool, including vaginal alpha-fetoprotein and IL-6, showed very good diagnostic performance for predicting the absence of intra-amniotic inflammation in women with preterm labor and intact membranes. |
|---|