Detection of cytomegalovirus in bronchoalveolar lavage fluid from immunocompromised patients with pneumonitis by viral culture and DNA quantification
Purpose: To compare the detection of human cytomegalovirus (HCMV) in bronchoalveolar lavage (BAL) fluid by viral culture and quantitative polymerase chain reaction (qPCR), and to establish a viral load threshold that can identify cases of HCMV replication indicative of pneumonitis. There is currentl...
| Autores: | , , , , , , , , , , , , |
|---|---|
| Tipo de recurso: | artículo |
| Estado: | Versión publicada |
| Fecha de publicación: | 2023 |
| País: | España |
| Institución: | Institut d’Investigació Biomèdica Sant Pau (IIB Sant Pau) |
| Repositorio: | r-IIB SANT PAU. Repositorio Institucional de Producción Científica del Instituto de Investigación Biomédica Sant Pau |
| OAI Identifier: | oai:iibsantpau.fundanetsuite.com:p16446 |
| Acceso en línea: | https://iibsantpau.fundanetsuite.com/Publicaciones/ProdCientif/PublicacionFrw.aspx?id=16446 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85158860392&doi=10.1016%2fj.jviromet.2023.114743&partnerID=40&md5=5f771acd5805c8410bdaf114fab68146 |
| Access Level: | acceso abierto |
| Palabra clave: | Cytomegalovirus HCMV Viral culture Quantitative PCR Viral load Pneumonitis Immunosuppressed |
| Sumario: | Purpose: To compare the detection of human cytomegalovirus (HCMV) in bronchoalveolar lavage (BAL) fluid by viral culture and quantitative polymerase chain reaction (qPCR), and to establish a viral load threshold that can identify cases of HCMV replication indicative of pneumonitis. There is currently no universal viral load cut-off to differentiate between patients with and without pneumonitis, and the interpretation of qPCR results is challenging.Methods: 176 consecutive BAL samples from immunosuppressed hosts with signs and/or symptoms of respiratory infection were prospectively studied by viral culture and qPCR.Results: Concordant results were obtained in 81.25% of the BAL samples. The rest were discordant, as only 34% of the qPCR-positive BAL samples were positive by culture. The median HCMV load was significantly higher in culture-positive than in culture-negative BAL samples (5038 vs 178 IU/mL). Using a cut-off value of 1258 IU/mL of HCMV in BAL, pneumonia was diagnosed with a sensitivity of 76%, a specificity of 100%, a VPP of 100% and VPN of 98%, and HCMV was isolated in 100% of the BAL cultures.Conclusion: We found that a qPCR-negative was a quick and reliable way of ruling out HCMV pneumonitis, but a positive result did not always indicate clinically significant replication in the lung. However, an HCMV load in BAL fluid of >= 1258 IU/mL was always associated with disease, whereas < 200 IU/mL rarely so. |
|---|