Compound-specific carbon isotope analysis of volatile organic compounds in water using solid-phase microextraction.

The compound-specific isotope analysis technique in conjunction with solid-phase microextraction using a Carboxen-polydimethylsiloxane fiber was tested and implemented for isotopes analysis of organic compounds aiming for environmental application in contaminated groundwater. δ13C values of several...

Descripción completa

Detalles Bibliográficos
Autores: Autor Palau, Jordi, Soler i Gil, Albert, Teixidor, P., Aravena R.
Tipo de recurso: artículo
Estado:Versión aceptada para publicación
Fecha de publicación:2007
País:España
Institución:Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)
Repositorio:Recercat. Dipósit de la Recerca de Catalunya
OAI Identifier:oai:recercat.cat:2445/163692
Acceso en línea:https://hdl.handle.net/2445/163692
Access Level:acceso abierto
Palabra clave:Hidrologia d'aigües subterrànies
Isòtops de carboni
Groundwater hydrology
Carbon isotopes
Descripción
Sumario:The compound-specific isotope analysis technique in conjunction with solid-phase microextraction using a Carboxen-polydimethylsiloxane fiber was tested and implemented for isotopes analysis of organic compounds aiming for environmental application in contaminated groundwater. δ13C values of several chlorinated methanes and ethenes, toluene and chlorobenzene were determined using a gas chromatograph coupled to an isotope ratio mass spectrometer through a combustion interface. Direct and headspace solid-phase microextraction (D-SPME, HS-SPME) methods were tested in order to determine the optimum conditions to obtain reproducible δ13C values at very low concentration (ug/L range) and, to elucidate the carbon isotopic effects associated with the competitive extraction. For D-SPME higher accuracy and precision of δ13C results were obtained with no salted aqueous standards. Despite that the δ13C of those compounds analyzed with both methods showed similar precision (< 0.5 ¿) and accuracy, the highest sensitivity was reached with HS-SPME. Furthermore, the δ13C values of cis-1,2-dichloroethylene, chorinated methanes and aromatic compounds obtained using HS-SPME showed measurable deviations respect to the isotopic composition of pure phase compounds, however, these deviations are constant according to the analytical uncertainties, indicating that they are not affected by competitive extraction and, they could be corrected using standard correction technique based on internal calibrated standards.