Stability of a Novel Intraocular Lens Design: Comparison of Two Trifocal Lenses

PURPOSE: To compare visual outcomes, rotational stability, and centration in a randomized controlled trial in patients undergoing cataract surgery who were bilaterally implanted with two different trifocal intraocular lenses (IOLs) with a similar optical zone but different haptic shape. METHODS: Twe...

Full description

Bibliographic Details
Authors: Poyales Galán, Francisco, Garzón Jiménez, Nuria, Rozema, Jos J., Romero Royo, Concepción, Ortíz de Zárate, Begoña
Format: article
Publication Date:2016
Country:España
Institution:Universidad Complutense de Madrid (UCM)
Repository:Docta Complutense
Language:English
OAI Identifier:oai:docta.ucm.es:20.500.14352/24551
Online Access:https://hdl.handle.net/20.500.14352/24551
Access Level:Open access
Keyword:617.7-089.243
617.741-004.1
681.735
Cataract surgery
Intraocular lenses
Trifocal intraocular lenses
IOLs
astigmatism
Oftalmología
Lentes de contacto
Optometría
Óptica oftálmica
3201.09 Oftalmología
3311.11 Instrumentos ópticos
2209.15 Optometría
Description
Summary:PURPOSE: To compare visual outcomes, rotational stability, and centration in a randomized controlled trial in patients undergoing cataract surgery who were bilaterally implanted with two different trifocal intraocular lenses (IOLs) with a similar optical zone but different haptic shape. METHODS: Twenty-one patients (42 eyes) with cataract and less than 1.50 D of corneal astigmatism underwent implantation of one FineVision/MicoF IOL in one eye and one POD FineVision IOL in the contralateral eye (PhysIOL, Liège, Belgium) at IOA Madrid Innova Ocular, Madrid, Spain. IOL allocation was random. Outcome measures, all evaluated 3 months postoperatively, included monocular and binocular uncorrected distance (UDVA), corrected distance (CDVA), distance-corrected intermediate (DCIVA), and near (DCNVA) visual acuity (at 80, 40, and 25 cm) under photopic conditions, refraction, IOL centration, haptic rotation, dysphotopsia, objective quality of vision and aberration quantification, patient satisfaction, and spectacle independence. RESULTS: Three months postoperatively, mean monocular UDVA, CDVA, DCIVA, and DCNVA (40 cm) under photopic conditions were 0.04 ± 0.07, 0.01 ± 0.04, 0.15 ± 0.11, and 0.16 ± 0.08 logMAR for the eyes implanted with the POD FineVision IOL and 0.03 ± 0.05, 0.01 ± 0.02, 0.17 ± 0.12, and 0.14 ± 0.08 logMAR for those receiving the FineVision/MicroF IOL. Moreover, the POD FineVision IOL showed similar centration (P > .05) and better rotational stability (P < .05) than the FineVision/MicroF IOL. Regarding halos, there was a minimal but statistically significant difference, obtaining better results with FineVision/MicroF. Full spectacle independence was reported by all patients. CONCLUSIONS: This study revealed similar visual outcomes for both trifocal IOLs under test (POD FineVision and FineVision/MicroF). However, the POD FineVision IOL showed better rotational stability, as afforded by its design.