Primary and secondary stability assessments of dental implants according to their macro-design, length, width, location, and bone quality
Some evidence supports the influence of implant macro-design on primary stability. Additionally, tactile perception can be used to assess implant stability when placing the implant. This research aimed to quantify the primary and secondary stability of three implant systems with two different macro...
| Autores: | , , , , , |
|---|---|
| Tipo de recurso: | artículo |
| Fecha de publicación: | 2024 |
| País: | España |
| Institución: | Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya) |
| Repositorio: | Recercat. Dipósit de la Recerca de Catalunya |
| OAI Identifier: | oai:recercat.cat:20.500.12328/4314 |
| Acceso en línea: | http://hdl.handle.net/20.500.12328/4314 https://dx.doi.org/10.3390/app14114841 |
| Access Level: | acceso abierto |
| Palabra clave: | Implants dentals Densitat òssia Macrodisseny Estabilitat de l'implant Tomografia computeritzada Qualitat òssia Implantes dentales Densidad osea Macrodiseño Estabilidad del implante Tomografía computarizada Calidad ósea Dental implants Bone density Macro-design Implant stability Computerized tomography Bone quality 616.3 |
| id |
ES_4faae9631e9ebaa419e932ea6907660f |
|---|---|
| oai_identifier_str |
oai:recercat.cat:20.500.12328/4314 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Primary and secondary stability assessments of dental implants according to their macro-design, length, width, location, and bone qualityQuispe-López, NorbertoMartín-Martín, SorayaGÓMEZ-POLO, CRISTINAFigueras-Alvarez, Oscarsanchez jorge, MARIA ISABELMONTERO, JAVIERImplants dentalsDensitat òssiaMacrodissenyEstabilitat de l'implantTomografia computeritzadaQualitat òssiaImplantes dentalesDensidad oseaMacrodiseñoEstabilidad del implanteTomografía computarizadaCalidad óseaDental implantsBone densityMacro-designImplant stabilityComputerized tomographyBone quality616.3Some evidence supports the influence of implant macro-design on primary stability. Additionally, tactile perception can be used to assess implant stability when placing the implant. This research aimed to quantify the primary and secondary stability of three implant systems with two different macro geometries (cylindrical and conical) determined based on the insertion torque and the implant stability quotient (ISQ) at the moment of implant placement as a function of implant-related factors (length, width, dental arch, and implant location in the arch), intraoperative factors (bone density determined subjectively by the clinician’s tactile perception), and patient-related factors (age, gender, and bone density determined objectively based on cone beam computed tomography (CBCT). Methods: 102 implants from three implant systems with two different macro geometries (conical and cylindrical) were placed in 53 patients. The insertion torque, the ISQ at the implant placement (ISQ0), and the bone quality according to the clinician’s tactile sensation were recorded on the day of the surgery. After a three-month healing period, the ISQ was re-evaluated (ISQ3). Results: The cylindrical implants exhibited significantly higher insertion torque and ISQ values at the moment of the surgery and after three months compared to the conical implants. The cylindrical implants also showed significantly lower indices of tactile evaluation of bone quality during the implant placement surgery. However, no differences were demonstrated in the bone density measured objectively using CBCT. (4) Conclusions: The cylindrical implants achieved the highest values for primary stability (Newtons × centimeter (Ncm) and ISQ) and secondary stability (ISQ after three months). The insertion torque was the variable that most influenced the ISQ on the day of the surgery. The implant location (incisors–canines, bicuspids–molars) and the implant macro geometry were the variables that most influenced the secondary stability (ISQ at three months).info:eu-repo/semantics/publishedVersionMDPI2024info:eu-repo/semantics/article17http://hdl.handle.net/20.500.12328/4314https://dx.doi.org/10.3390/app14114841reponame:Recercat. Dipósit de la Recerca de Catalunyainstname:Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)InglésApplied Sciences14;11© 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).https://creativecommons.org/licenses/by/4.0/info:eu-repo/semantics/openAccessoai:recercat.cat:20.500.12328/43142026-05-29T05:05:01Z |
| dc.title.none.fl_str_mv |
Primary and secondary stability assessments of dental implants according to their macro-design, length, width, location, and bone quality |
| title |
Primary and secondary stability assessments of dental implants according to their macro-design, length, width, location, and bone quality |
| spellingShingle |
Primary and secondary stability assessments of dental implants according to their macro-design, length, width, location, and bone quality Quispe-López, Norberto Implants dentals Densitat òssia Macrodisseny Estabilitat de l'implant Tomografia computeritzada Qualitat òssia Implantes dentales Densidad osea Macrodiseño Estabilidad del implante Tomografía computarizada Calidad ósea Dental implants Bone density Macro-design Implant stability Computerized tomography Bone quality 616.3 |
| title_short |
Primary and secondary stability assessments of dental implants according to their macro-design, length, width, location, and bone quality |
| title_full |
Primary and secondary stability assessments of dental implants according to their macro-design, length, width, location, and bone quality |
| title_fullStr |
Primary and secondary stability assessments of dental implants according to their macro-design, length, width, location, and bone quality |
| title_full_unstemmed |
Primary and secondary stability assessments of dental implants according to their macro-design, length, width, location, and bone quality |
| title_sort |
Primary and secondary stability assessments of dental implants according to their macro-design, length, width, location, and bone quality |
| dc.creator.none.fl_str_mv |
Quispe-López, Norberto Martín-Martín, Soraya GÓMEZ-POLO, CRISTINA Figueras-Alvarez, Oscar sanchez jorge, MARIA ISABEL MONTERO, JAVIER |
| author |
Quispe-López, Norberto |
| author_facet |
Quispe-López, Norberto Martín-Martín, Soraya GÓMEZ-POLO, CRISTINA Figueras-Alvarez, Oscar sanchez jorge, MARIA ISABEL MONTERO, JAVIER |
| author_role |
author |
| author2 |
Martín-Martín, Soraya GÓMEZ-POLO, CRISTINA Figueras-Alvarez, Oscar sanchez jorge, MARIA ISABEL MONTERO, JAVIER |
| author2_role |
author author author author author |
| dc.subject.none.fl_str_mv |
Implants dentals Densitat òssia Macrodisseny Estabilitat de l'implant Tomografia computeritzada Qualitat òssia Implantes dentales Densidad osea Macrodiseño Estabilidad del implante Tomografía computarizada Calidad ósea Dental implants Bone density Macro-design Implant stability Computerized tomography Bone quality 616.3 |
| topic |
Implants dentals Densitat òssia Macrodisseny Estabilitat de l'implant Tomografia computeritzada Qualitat òssia Implantes dentales Densidad osea Macrodiseño Estabilidad del implante Tomografía computarizada Calidad ósea Dental implants Bone density Macro-design Implant stability Computerized tomography Bone quality 616.3 |
| description |
Some evidence supports the influence of implant macro-design on primary stability. Additionally, tactile perception can be used to assess implant stability when placing the implant. This research aimed to quantify the primary and secondary stability of three implant systems with two different macro geometries (cylindrical and conical) determined based on the insertion torque and the implant stability quotient (ISQ) at the moment of implant placement as a function of implant-related factors (length, width, dental arch, and implant location in the arch), intraoperative factors (bone density determined subjectively by the clinician’s tactile perception), and patient-related factors (age, gender, and bone density determined objectively based on cone beam computed tomography (CBCT). Methods: 102 implants from three implant systems with two different macro geometries (conical and cylindrical) were placed in 53 patients. The insertion torque, the ISQ at the implant placement (ISQ0), and the bone quality according to the clinician’s tactile sensation were recorded on the day of the surgery. After a three-month healing period, the ISQ was re-evaluated (ISQ3). Results: The cylindrical implants exhibited significantly higher insertion torque and ISQ values at the moment of the surgery and after three months compared to the conical implants. The cylindrical implants also showed significantly lower indices of tactile evaluation of bone quality during the implant placement surgery. However, no differences were demonstrated in the bone density measured objectively using CBCT. (4) Conclusions: The cylindrical implants achieved the highest values for primary stability (Newtons × centimeter (Ncm) and ISQ) and secondary stability (ISQ after three months). The insertion torque was the variable that most influenced the ISQ on the day of the surgery. The implant location (incisors–canines, bicuspids–molars) and the implant macro geometry were the variables that most influenced the secondary stability (ISQ at three months). |
| publishDate |
2024 |
| dc.date.none.fl_str_mv |
2024 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| dc.identifier.none.fl_str_mv |
http://hdl.handle.net/20.500.12328/4314 https://dx.doi.org/10.3390/app14114841 |
| url |
http://hdl.handle.net/20.500.12328/4314 https://dx.doi.org/10.3390/app14114841 |
| dc.language.none.fl_str_mv |
Inglés |
| language_invalid_str_mv |
Inglés |
| dc.relation.none.fl_str_mv |
Applied Sciences 14;11 |
| dc.rights.none.fl_str_mv |
https://creativecommons.org/licenses/by/4.0/ info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
https://creativecommons.org/licenses/by/4.0/ |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
17 |
| dc.publisher.none.fl_str_mv |
MDPI |
| publisher.none.fl_str_mv |
MDPI |
| dc.source.none.fl_str_mv |
reponame:Recercat. Dipósit de la Recerca de Catalunya instname:Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya) |
| instname_str |
Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya) |
| reponame_str |
Recercat. Dipósit de la Recerca de Catalunya |
| collection |
Recercat. Dipósit de la Recerca de Catalunya |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869407833920897024 |
| score |
15,81155 |