Visual Results After Extended Depth-of-Focus Lens Implantation in Patients Undergoing Clear Lens Surgery
Background/Objectives: To evaluate the efficacy and visual quality provided by the extended depth-of-focus AcrySof IQ Vivity lens (Alcon Laboratories, Inc., Fort Worth, TX, USA) in patients undergoing refractive lens exchange (RLE) surgery for presbyopia correction. Methods: This descriptive prospec...
| Autores: | , , , |
|---|---|
| Formato: | artículo |
| Fecha de publicación: | 2025 |
| País: | España |
| Recursos: | Universidad Complutense de Madrid (UCM) |
| Repositorio: | Docta Complutense |
| Idioma: | inglés |
| OAI Identifier: | oai:docta.ucm.es:20.500.14352/119624 |
| Acesso em linha: | https://hdl.handle.net/20.500.14352/119624 |
| Access Level: | acceso abierto |
| Palavra-chave: | 617.7-089.243 Extended depth-of-focus Presbyopia Refractive lens exchange Ciencias Ciencias Biomédicas 32 Ciencias Médicas 22 Física |
| id |
ES_4f04cbf179aa12e8d2b69bf86b6039ae |
|---|---|
| oai_identifier_str |
oai:docta.ucm.es:20.500.14352/119624 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Visual Results After Extended Depth-of-Focus Lens Implantation in Patients Undergoing Clear Lens SurgeryBarberá-Loustaunau, EmanuelCouñago, FelipeSánchez Tena, Miguel ÁngelGarzón Jiménez, Nuria617.7-089.243Extended depth-of-focusPresbyopiaRefractive lens exchangeCienciasCiencias Biomédicas32 Ciencias Médicas22 FísicaBackground/Objectives: To evaluate the efficacy and visual quality provided by the extended depth-of-focus AcrySof IQ Vivity lens (Alcon Laboratories, Inc., Fort Worth, TX, USA) in patients undergoing refractive lens exchange (RLE) surgery for presbyopia correction. Methods: This descriptive prospective single-arm clinical study included 30 patients (60 eyes) aged 49–69 years (mean 60.2) who underwent clear lens surgery for presbyopia correction. Postoperative 3-month assessments included uncorrected distance visual acuity (UDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA), distance-corrected intermediate visual acuity (DCIVA), and distance-corrected near visual acuity (DCNVA) measurements. Patient satisfaction and visual disturbances were evaluated using a standardized questionnaire. Results: Postoperative binocular visual acuity results were as follows: UDVA, 0.00 ± 0.06 logMAR; UIVA 0.08 ± 0.07 logMAR; and UNVA, 0.18 ± 0.10 logMAR. Refractive outcomes showed mean spherical equivalent values of −0.15 D ± 0.28 diopters (D) for the right eye and −0.18 D ± 0.30 D for the left eye postoperatively. Most patients (93.2%) were satisfied or very satisfied with the surgery, and 63.3% never needed glasses at any distance postoperatively. Mild and non-disabling photic phenomena were reported by 23% of patients for halos and 30% for glares. Conclusions: The study IOL provides excellent visual acuity for far and intermediate distances, as well as functional near vision under photopic conditions, with high levels of patient satisfaction and minimal visual disturbances. This lens is a promising option for non-cataract patients undergoing RLE for presbyopia correction.MDPIUniversidad Complutense de Madrid20252025-04-1820252025-04-18journal articlehttp://purl.org/coar/resource_type/c_6501VoRhttp://purl.org/coar/version/c_970fb48d4fbd8a85info:eu-repo/semantics/articleapplication/pdfhttps://hdl.handle.net/20.500.14352/119624reponame:Docta Complutenseinstname:Universidad Complutense de Madrid (UCM)Inglésengopen accesshttp://purl.org/coar/access_right/c_abf2info:eu-repo/semantics/openAccessoai:docta.ucm.es:20.500.14352/1196242026-06-02T12:44:21Z |
| dc.title.none.fl_str_mv |
Visual Results After Extended Depth-of-Focus Lens Implantation in Patients Undergoing Clear Lens Surgery |
| title |
Visual Results After Extended Depth-of-Focus Lens Implantation in Patients Undergoing Clear Lens Surgery |
| spellingShingle |
Visual Results After Extended Depth-of-Focus Lens Implantation in Patients Undergoing Clear Lens Surgery Barberá-Loustaunau, Emanuel 617.7-089.243 Extended depth-of-focus Presbyopia Refractive lens exchange Ciencias Ciencias Biomédicas 32 Ciencias Médicas 22 Física |
| title_short |
Visual Results After Extended Depth-of-Focus Lens Implantation in Patients Undergoing Clear Lens Surgery |
| title_full |
Visual Results After Extended Depth-of-Focus Lens Implantation in Patients Undergoing Clear Lens Surgery |
| title_fullStr |
Visual Results After Extended Depth-of-Focus Lens Implantation in Patients Undergoing Clear Lens Surgery |
| title_full_unstemmed |
Visual Results After Extended Depth-of-Focus Lens Implantation in Patients Undergoing Clear Lens Surgery |
| title_sort |
Visual Results After Extended Depth-of-Focus Lens Implantation in Patients Undergoing Clear Lens Surgery |
| dc.creator.none.fl_str_mv |
Barberá-Loustaunau, Emanuel Couñago, Felipe Sánchez Tena, Miguel Ángel Garzón Jiménez, Nuria |
| author |
Barberá-Loustaunau, Emanuel |
| author_facet |
Barberá-Loustaunau, Emanuel Couñago, Felipe Sánchez Tena, Miguel Ángel Garzón Jiménez, Nuria |
| author_role |
author |
| author2 |
Couñago, Felipe Sánchez Tena, Miguel Ángel Garzón Jiménez, Nuria |
| author2_role |
author author author |
| dc.contributor.none.fl_str_mv |
Universidad Complutense de Madrid |
| dc.subject.none.fl_str_mv |
617.7-089.243 Extended depth-of-focus Presbyopia Refractive lens exchange Ciencias Ciencias Biomédicas 32 Ciencias Médicas 22 Física |
| topic |
617.7-089.243 Extended depth-of-focus Presbyopia Refractive lens exchange Ciencias Ciencias Biomédicas 32 Ciencias Médicas 22 Física |
| description |
Background/Objectives: To evaluate the efficacy and visual quality provided by the extended depth-of-focus AcrySof IQ Vivity lens (Alcon Laboratories, Inc., Fort Worth, TX, USA) in patients undergoing refractive lens exchange (RLE) surgery for presbyopia correction. Methods: This descriptive prospective single-arm clinical study included 30 patients (60 eyes) aged 49–69 years (mean 60.2) who underwent clear lens surgery for presbyopia correction. Postoperative 3-month assessments included uncorrected distance visual acuity (UDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA), distance-corrected intermediate visual acuity (DCIVA), and distance-corrected near visual acuity (DCNVA) measurements. Patient satisfaction and visual disturbances were evaluated using a standardized questionnaire. Results: Postoperative binocular visual acuity results were as follows: UDVA, 0.00 ± 0.06 logMAR; UIVA 0.08 ± 0.07 logMAR; and UNVA, 0.18 ± 0.10 logMAR. Refractive outcomes showed mean spherical equivalent values of −0.15 D ± 0.28 diopters (D) for the right eye and −0.18 D ± 0.30 D for the left eye postoperatively. Most patients (93.2%) were satisfied or very satisfied with the surgery, and 63.3% never needed glasses at any distance postoperatively. Mild and non-disabling photic phenomena were reported by 23% of patients for halos and 30% for glares. Conclusions: The study IOL provides excellent visual acuity for far and intermediate distances, as well as functional near vision under photopic conditions, with high levels of patient satisfaction and minimal visual disturbances. This lens is a promising option for non-cataract patients undergoing RLE for presbyopia correction. |
| publishDate |
2025 |
| dc.date.none.fl_str_mv |
2025 2025-04-18 2025 2025-04-18 |
| dc.type.none.fl_str_mv |
journal article http://purl.org/coar/resource_type/c_6501 VoR http://purl.org/coar/version/c_970fb48d4fbd8a85 |
| dc.type.openaire.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| dc.identifier.none.fl_str_mv |
https://hdl.handle.net/20.500.14352/119624 |
| url |
https://hdl.handle.net/20.500.14352/119624 |
| dc.language.none.fl_str_mv |
Inglés eng |
| language_invalid_str_mv |
Inglés |
| language |
eng |
| dc.rights.none.fl_str_mv |
open access http://purl.org/coar/access_right/c_abf2 |
| dc.rights.openaire.fl_str_mv |
info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
open access http://purl.org/coar/access_right/c_abf2 |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
MDPI |
| publisher.none.fl_str_mv |
MDPI |
| dc.source.none.fl_str_mv |
reponame:Docta Complutense instname:Universidad Complutense de Madrid (UCM) |
| instname_str |
Universidad Complutense de Madrid (UCM) |
| reponame_str |
Docta Complutense |
| collection |
Docta Complutense |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869407793325277184 |
| score |
15,811543 |