Numerical study of upstream disturbances on the performance of electromagnetic and ultrasonic flowmeters

[EN] Electromagnetic and ultrasonic flowmeters are high precision devices that can measure the water flow in pressurized irrigation networks. In these networks, the inadequate installation distance of flow control valves generates upstream disturbances which will increase measurement errors and redu...

ver descrição completa

Detalhes bibliográficos
Autores: Palau C.V.|||0000-0002-9065-8206, Balbastre Peralta, Iban|||0000-0002-7982-7224, do Bomfim, Guilherme Vieira, Moreira de Azevedo, Benito
Tipo de documento: artigo
Data de publicação:2020
País:España
Recursos:Universitat Politècnica de València (UPV)
Repositório:RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Idioma:inglês
OAI Identifier:oai:riunet.upv.es:10251/192949
Acesso em linha:https://riunet.upv.es/handle/10251/192949
Access Level:Acceso aberto
Palavra-chave:CFD
Pressurized irrigation
Water flowmeter
Water supply Network
INGENIERIA AGROFORESTAL
06.- Garantizar la disponibilidad y la gestión sostenible del agua y el saneamiento para todos
id ES_4cbb6a25f95e96e6de41ee23a40da587
oai_identifier_str oai:riunet.upv.es:10251/192949
network_acronym_str ES
network_name_str España
repository_id_str
spelling Numerical study of upstream disturbances on the performance of electromagnetic and ultrasonic flowmetersPalau C.V.|||0000-0002-9065-8206Balbastre Peralta, Iban|||0000-0002-7982-7224do Bomfim, Guilherme VieiraMoreira de Azevedo, BenitoCFDPressurized irrigationWater flowmeterWater supply NetworkINGENIERIA AGROFORESTAL06.- Garantizar la disponibilidad y la gestión sostenible del agua y el saneamiento para todos[EN] Electromagnetic and ultrasonic flowmeters are high precision devices that can measure the water flow in pressurized irrigation networks. In these networks, the inadequate installation distance of flow control valves generates upstream disturbances which will increase measurement errors and reduce the accuracy of the equipment. Therefore, estimating these errors is important to establishing the correct installation distance of the hydraulic accessories and to ensuring the metrological reliability of the flowmeters. This work proposes a numerical study using Computational Fluid Dynamics to evaluate water flow behavior in pipes and estimate measurement errors caused by gate and butterfly valves in installation configurations found at pressurized irrigation networks. The numerical simulations were made for gate (15, 50 and 75 % closed) and butterfly (open and 30" closed) valves installed three and six diameters (3D and 6D) from the flowmeters. The numerical study with three-dimensional simulation allows for evaluating the flow behavior and estimating measurement errors correctly. According to the study, the installation configurations of the gate and butterfly valves change the flow velocity profile at different positions in the pipe, generating both positive and negative measurement errors at both flowmeters. Among the tested configurations, only the butterfly valve installed 3D and 6D from the electromagnetic flowmeter ensured the measurement accuracy required by ISO 4064.Universidade de Sao PauloDepartamento de Ingeniería Rural y AgroalimentariaCentro Valenciano de Estudios sobre el RiegoEscuela Técnica Superior de Ingeniería Agronómica y del Medio NaturalRepositorio Institucional de la Universitat Politècnica de València Riunet20202020-01-01journal articlehttp://purl.org/coar/resource_type/c_6501VoRhttp://purl.org/coar/version/c_970fb48d4fbd8a85info:eu-repo/semantics/articleapplication/pdfhttps://riunet.upv.es/handle/10251/192949reponame:RiuNet. Repositorio Institucional de la Universitat Politécnica de Valénciainstname:Universitat Politècnica de València (UPV)Inglésengopen accesshttp://purl.org/coar/access_right/c_abf2Reconocimiento (by)http://creativecommons.org/licenses/by/4.0/info:eu-repo/semantics/openAccessoai:riunet.upv.es:10251/1929492026-06-13T07:49:27Z
dc.title.none.fl_str_mv Numerical study of upstream disturbances on the performance of electromagnetic and ultrasonic flowmeters
title Numerical study of upstream disturbances on the performance of electromagnetic and ultrasonic flowmeters
spellingShingle Numerical study of upstream disturbances on the performance of electromagnetic and ultrasonic flowmeters
Palau C.V.|||0000-0002-9065-8206
CFD
Pressurized irrigation
Water flowmeter
Water supply Network
INGENIERIA AGROFORESTAL
06.- Garantizar la disponibilidad y la gestión sostenible del agua y el saneamiento para todos
title_short Numerical study of upstream disturbances on the performance of electromagnetic and ultrasonic flowmeters
title_full Numerical study of upstream disturbances on the performance of electromagnetic and ultrasonic flowmeters
title_fullStr Numerical study of upstream disturbances on the performance of electromagnetic and ultrasonic flowmeters
title_full_unstemmed Numerical study of upstream disturbances on the performance of electromagnetic and ultrasonic flowmeters
title_sort Numerical study of upstream disturbances on the performance of electromagnetic and ultrasonic flowmeters
dc.creator.none.fl_str_mv Palau C.V.|||0000-0002-9065-8206
Balbastre Peralta, Iban|||0000-0002-7982-7224
do Bomfim, Guilherme Vieira
Moreira de Azevedo, Benito
author Palau C.V.|||0000-0002-9065-8206
author_facet Palau C.V.|||0000-0002-9065-8206
Balbastre Peralta, Iban|||0000-0002-7982-7224
do Bomfim, Guilherme Vieira
Moreira de Azevedo, Benito
author_role author
author2 Balbastre Peralta, Iban|||0000-0002-7982-7224
do Bomfim, Guilherme Vieira
Moreira de Azevedo, Benito
author2_role author
author
author
dc.contributor.none.fl_str_mv Departamento de Ingeniería Rural y Agroalimentaria
Centro Valenciano de Estudios sobre el Riego
Escuela Técnica Superior de Ingeniería Agronómica y del Medio Natural
Repositorio Institucional de la Universitat Politècnica de València Riunet
dc.subject.none.fl_str_mv CFD
Pressurized irrigation
Water flowmeter
Water supply Network
INGENIERIA AGROFORESTAL
06.- Garantizar la disponibilidad y la gestión sostenible del agua y el saneamiento para todos
topic CFD
Pressurized irrigation
Water flowmeter
Water supply Network
INGENIERIA AGROFORESTAL
06.- Garantizar la disponibilidad y la gestión sostenible del agua y el saneamiento para todos
description [EN] Electromagnetic and ultrasonic flowmeters are high precision devices that can measure the water flow in pressurized irrigation networks. In these networks, the inadequate installation distance of flow control valves generates upstream disturbances which will increase measurement errors and reduce the accuracy of the equipment. Therefore, estimating these errors is important to establishing the correct installation distance of the hydraulic accessories and to ensuring the metrological reliability of the flowmeters. This work proposes a numerical study using Computational Fluid Dynamics to evaluate water flow behavior in pipes and estimate measurement errors caused by gate and butterfly valves in installation configurations found at pressurized irrigation networks. The numerical simulations were made for gate (15, 50 and 75 % closed) and butterfly (open and 30" closed) valves installed three and six diameters (3D and 6D) from the flowmeters. The numerical study with three-dimensional simulation allows for evaluating the flow behavior and estimating measurement errors correctly. According to the study, the installation configurations of the gate and butterfly valves change the flow velocity profile at different positions in the pipe, generating both positive and negative measurement errors at both flowmeters. Among the tested configurations, only the butterfly valve installed 3D and 6D from the electromagnetic flowmeter ensured the measurement accuracy required by ISO 4064.
publishDate 2020
dc.date.none.fl_str_mv 2020
2020-01-01
dc.type.none.fl_str_mv journal article
http://purl.org/coar/resource_type/c_6501
VoR
http://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.openaire.fl_str_mv info:eu-repo/semantics/article
format article
dc.identifier.none.fl_str_mv https://riunet.upv.es/handle/10251/192949
url https://riunet.upv.es/handle/10251/192949
dc.language.none.fl_str_mv Inglés
eng
language_invalid_str_mv Inglés
language eng
dc.rights.none.fl_str_mv open access
http://purl.org/coar/access_right/c_abf2
Reconocimiento (by)
http://creativecommons.org/licenses/by/4.0/
dc.rights.openaire.fl_str_mv info:eu-repo/semantics/openAccess
rights_invalid_str_mv open access
http://purl.org/coar/access_right/c_abf2
Reconocimiento (by)
http://creativecommons.org/licenses/by/4.0/
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade de Sao Paulo
publisher.none.fl_str_mv Universidade de Sao Paulo
dc.source.none.fl_str_mv reponame:RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
instname:Universitat Politècnica de València (UPV)
instname_str Universitat Politècnica de València (UPV)
reponame_str RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
collection RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869407646176509952
score 15.301603