Field-amplified sample injection-micellar electrokinetic capillary chromatography for the analysis of bisphenol A, bisphenol F, and their diglycidyl ethers and derivatives in canned soft drinks
Conditions were established for the separation and analysis of Bisphenol A (BPA), Bisphenol F (BPF), and their diglycidyl ethers, by micellar electrokinetic capillary chromatography (MECC). Good resolution was obtained for all compounds, although in order to achieve the separation of ortho-ortho, or...
| Autores: | , , , |
|---|---|
| Tipo de recurso: | artículo |
| Estado: | Versión aceptada para publicación |
| Fecha de publicación: | 2010 |
| País: | España |
| Institución: | Universidad de Barcelona |
| Repositorio: | Dipòsit Digital de la UB |
| OAI Identifier: | oai:diposit.ub.edu:2445/98193 |
| Acceso en línea: | https://hdl.handle.net/2445/98193 |
| Access Level: | acceso abierto |
| Palabra clave: | Begudes carbòniques Química dels aliments Fenols Cromatografia Envasament d'aliments Carbonated beverages Food composition Phenols Chromatography Food packaging |
| id |
ES_4ba3b5e2a9c0ef16924b42e86473edde |
|---|---|
| oai_identifier_str |
oai:diposit.ub.edu:2445/98193 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Field-amplified sample injection-micellar electrokinetic capillary chromatography for the analysis of bisphenol A, bisphenol F, and their diglycidyl ethers and derivatives in canned soft drinksGallart Ayala, HèctorNúñez Burcio, OscarMoyano Morcillo, EncarnaciónGalcerán Huguet, M. TeresaBegudes carbòniquesQuímica dels alimentsFenolsCromatografiaEnvasament d'alimentsCarbonated beveragesFood compositionPhenolsChromatographyFood packagingConditions were established for the separation and analysis of Bisphenol A (BPA), Bisphenol F (BPF), and their diglycidyl ethers, by micellar electrokinetic capillary chromatography (MECC). Good resolution was obtained for all compounds, although in order to achieve the separation of ortho-ortho, ortho-para, and para-para isomers of Bisphenol F diglycidyl ether (BFDGE), BFDGE¿2H2O and BFDGE¿2HCl, it was necessary to use a 25 µm I.D. fused-silica capillary. To increase sensitivity, a field amplified sample injection (FASI)-MECC method was developed using 10 mM sodium dodecyl sulfate (SDS) solution as injection matrix and a 75 µm I.D. fused-silica capillary. Instrumental quality parameters such as limits of detection (0.999), and run-to-run and day-to-day precisions (relative standard deviations (RSD) values lower than 12.5%) were determined. Finally, the suitability of the FASI-MECC method for the analysis of BPA, BPF and their diglycidyl ethers in canned soft-drinks was evaluated. Quantitation was performed by matrix-matched calibration using a plastic-bottled isotonic drink as matrix. The results showed that FASI-MECC is an economic method for the screening and quantitation of these kinds of compounds in soft-drink beverages, with no loss of reproducibility, and effective at concentrations lower than the specific migration level (SML) values established by the European Union.Wiley-VCH2010info:eu-repo/semantics/articleinfo:eu-repo/semantics/acceptedVersionapplication/pdfhttps://hdl.handle.net/2445/98193Articles publicats en revistes (Enginyeria Química i Química Analítica)reponame:Dipòsit Digital de la UBinstname:Universidad de BarcelonaInglésVersió postprint del document publicat a: http://dx.doi.org/10.1002/elps.200900606Electrophoresis, 2010, vol. 31, num. 9, p. 1550-1559http://dx.doi.org/10.1002/elps.200900606(c) Wiley-VCH, 2010info:eu-repo/semantics/openAccessoai:diposit.ub.edu:2445/981932026-05-27T06:46:51Z |
| dc.title.none.fl_str_mv |
Field-amplified sample injection-micellar electrokinetic capillary chromatography for the analysis of bisphenol A, bisphenol F, and their diglycidyl ethers and derivatives in canned soft drinks |
| title |
Field-amplified sample injection-micellar electrokinetic capillary chromatography for the analysis of bisphenol A, bisphenol F, and their diglycidyl ethers and derivatives in canned soft drinks |
| spellingShingle |
Field-amplified sample injection-micellar electrokinetic capillary chromatography for the analysis of bisphenol A, bisphenol F, and their diglycidyl ethers and derivatives in canned soft drinks Gallart Ayala, Hèctor Begudes carbòniques Química dels aliments Fenols Cromatografia Envasament d'aliments Carbonated beverages Food composition Phenols Chromatography Food packaging |
| title_short |
Field-amplified sample injection-micellar electrokinetic capillary chromatography for the analysis of bisphenol A, bisphenol F, and their diglycidyl ethers and derivatives in canned soft drinks |
| title_full |
Field-amplified sample injection-micellar electrokinetic capillary chromatography for the analysis of bisphenol A, bisphenol F, and their diglycidyl ethers and derivatives in canned soft drinks |
| title_fullStr |
Field-amplified sample injection-micellar electrokinetic capillary chromatography for the analysis of bisphenol A, bisphenol F, and their diglycidyl ethers and derivatives in canned soft drinks |
| title_full_unstemmed |
Field-amplified sample injection-micellar electrokinetic capillary chromatography for the analysis of bisphenol A, bisphenol F, and their diglycidyl ethers and derivatives in canned soft drinks |
| title_sort |
Field-amplified sample injection-micellar electrokinetic capillary chromatography for the analysis of bisphenol A, bisphenol F, and their diglycidyl ethers and derivatives in canned soft drinks |
| dc.creator.none.fl_str_mv |
Gallart Ayala, Hèctor Núñez Burcio, Oscar Moyano Morcillo, Encarnación Galcerán Huguet, M. Teresa |
| author |
Gallart Ayala, Hèctor |
| author_facet |
Gallart Ayala, Hèctor Núñez Burcio, Oscar Moyano Morcillo, Encarnación Galcerán Huguet, M. Teresa |
| author_role |
author |
| author2 |
Núñez Burcio, Oscar Moyano Morcillo, Encarnación Galcerán Huguet, M. Teresa |
| author2_role |
author author author |
| dc.subject.none.fl_str_mv |
Begudes carbòniques Química dels aliments Fenols Cromatografia Envasament d'aliments Carbonated beverages Food composition Phenols Chromatography Food packaging |
| topic |
Begudes carbòniques Química dels aliments Fenols Cromatografia Envasament d'aliments Carbonated beverages Food composition Phenols Chromatography Food packaging |
| description |
Conditions were established for the separation and analysis of Bisphenol A (BPA), Bisphenol F (BPF), and their diglycidyl ethers, by micellar electrokinetic capillary chromatography (MECC). Good resolution was obtained for all compounds, although in order to achieve the separation of ortho-ortho, ortho-para, and para-para isomers of Bisphenol F diglycidyl ether (BFDGE), BFDGE¿2H2O and BFDGE¿2HCl, it was necessary to use a 25 µm I.D. fused-silica capillary. To increase sensitivity, a field amplified sample injection (FASI)-MECC method was developed using 10 mM sodium dodecyl sulfate (SDS) solution as injection matrix and a 75 µm I.D. fused-silica capillary. Instrumental quality parameters such as limits of detection (0.999), and run-to-run and day-to-day precisions (relative standard deviations (RSD) values lower than 12.5%) were determined. Finally, the suitability of the FASI-MECC method for the analysis of BPA, BPF and their diglycidyl ethers in canned soft-drinks was evaluated. Quantitation was performed by matrix-matched calibration using a plastic-bottled isotonic drink as matrix. The results showed that FASI-MECC is an economic method for the screening and quantitation of these kinds of compounds in soft-drink beverages, with no loss of reproducibility, and effective at concentrations lower than the specific migration level (SML) values established by the European Union. |
| publishDate |
2010 |
| dc.date.none.fl_str_mv |
2010 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/acceptedVersion |
| format |
article |
| status_str |
acceptedVersion |
| dc.identifier.none.fl_str_mv |
https://hdl.handle.net/2445/98193 |
| url |
https://hdl.handle.net/2445/98193 |
| dc.language.none.fl_str_mv |
Inglés |
| language_invalid_str_mv |
Inglés |
| dc.relation.none.fl_str_mv |
Versió postprint del document publicat a: http://dx.doi.org/10.1002/elps.200900606 Electrophoresis, 2010, vol. 31, num. 9, p. 1550-1559 http://dx.doi.org/10.1002/elps.200900606 |
| dc.rights.none.fl_str_mv |
(c) Wiley-VCH, 2010 info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
(c) Wiley-VCH, 2010 |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
Wiley-VCH |
| publisher.none.fl_str_mv |
Wiley-VCH |
| dc.source.none.fl_str_mv |
Articles publicats en revistes (Enginyeria Química i Química Analítica) reponame:Dipòsit Digital de la UB instname:Universidad de Barcelona |
| instname_str |
Universidad de Barcelona |
| reponame_str |
Dipòsit Digital de la UB |
| collection |
Dipòsit Digital de la UB |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869407573830008832 |
| score |
15,301603 |