Comparison of visual performance between two aspheric monofocal intraocular lens models
Clinical relevance It is important to distinguish between visual acuity, optical quality and quality of vision when outcomes obtained with intraocular lenses are evaluated. These parameters, that includeobjective and subjective tests, should be assessed to obtain results that are not biased. Backgro...
| Autores: | , , , , , |
|---|---|
| Tipo de recurso: | artículo |
| Fecha de publicación: | 2021 |
| País: | España |
| Institución: | Universitat Politècnica de Catalunya (UPC) |
| Repositorio: | UPCommons. Portal del coneixement obert de la UPC |
| Idioma: | inglés |
| OAI Identifier: | oai:upcommons.upc.edu:2117/364469 |
| Acceso en línea: | https://hdl.handle.net/2117/364469 https://dx.doi.org/10.1080/08164622.2021.2009737 |
| Access Level: | acceso abierto |
| Palabra clave: | Intraocular lenses Visual acuity Quantity of vision Optical quality Visual qualit Monofocal intraocular lens Lents intraoculars Agudesa visual Àrees temàtiques de la UPC::Ciències de la visió |
| id |
ES_4aa1dc88a33a2afcb2c633b5ae98a8a3 |
|---|---|
| oai_identifier_str |
oai:upcommons.upc.edu:2117/364469 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Comparison of visual performance between two aspheric monofocal intraocular lens modelsPoyales, FranciscoGarzon, NuriaRico del Viejo Miranza, LauraZhou, YingMillán Garcia-Varela, M. Sagrario|||0000-0001-6950-2373Vega Lerín, Fidel|||0000-0002-8594-0872Intraocular lensesVisual acuityQuantity of visionOptical qualityVisual qualitMonofocal intraocular lensLents intraocularsAgudesa visualÀrees temàtiques de la UPC::Ciències de la visióClinical relevance It is important to distinguish between visual acuity, optical quality and quality of vision when outcomes obtained with intraocular lenses are evaluated. These parameters, that includeobjective and subjective tests, should be assessed to obtain results that are not biased. Background To assess the difference in visual and optical quality between two monofocal intraocular lens models. Methods : This was a prospective, parallel and randomised clinical study conducted at Miranza IOA, a private clinic in Madrid, Spain. Sixty patients were implanted bilaterally, 30 per group, with two aspheric IOLs with induced spherical aberration of -0.27 µm for Group A and -0.20 µm for Group B. Visual outcomes obtained at 1 and 3 months after surgery included both uncorrected (UCVA) and corrected monocular distance visual acuity (DCVA), objective scattering index (OSI), modulation transfer function (MTF) cut-off, Strehl Ratio (SR), contrast sensitivity defocus curve (CSDC), intraocular lens spherical aberration (SA), and longitudinal chromatic aberration of the eye. Activity limitations in daily life were assessed using CatQuest-9SF questionnaire. Results There were statistically significant differences for DCVA (0.04 LogMAR; p = .008) and SR (0.03; p = .003) between groups. Outcomes related to CSDC showed statistically significant differences for vergences between -0.50 D and +1.00 D (3 mm pupil) and for vergences of 0.00 D and +0.50 D (4.5 mm pupil) between groups. Overall, Group A showed better results regarding visual and optical quality, including a lower longitudinal chromatic aberration result in comparison to Group B. Patient satisfaction evaluated with CatQuest-9SF showed that Group A achieved better outcomes, although the differences were statistically significant only for the ‘Reading text on television’ item (p = 0.027). Conclusions Both intraocular lens models showed excellent quantity of vision, optical and visual quality as well as high patient satisfaction. Despite this, the the Group A model provided slightly better outcomes than the Group B model.This study was partially funded by an unrestricted research grant from Johnson and Johnson Vision.Peer ReviewedTaylor & Francis20212021-12-0720222022-03-17journal articlehttp://purl.org/coar/resource_type/c_6501AMhttp://purl.org/coar/version/c_ab4af688f83e57aainfo:eu-repo/semantics/articleapplication/pdfhttps://hdl.handle.net/2117/364469https://dx.doi.org/10.1080/08164622.2021.2009737reponame:UPCommons. Portal del coneixement obert de la UPCinstname:Universitat Politècnica de Catalunya (UPC)InglésengAgencia Estatal de Investigación http://doi.org/10.13039/501100011033 Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020 PID2020-114582RB-I00 IMPLANTES OPTICOS INTRAOCULARES CORRECTORES DE LA PRESBICIA PARA UNA COMPENSACION VISUAL PERSONALIZADAopen accesshttp://purl.org/coar/access_right/c_abf2info:eu-repo/semantics/openAccessoai:upcommons.upc.edu:2117/3644692026-05-27T15:37:01Z |
| dc.title.none.fl_str_mv |
Comparison of visual performance between two aspheric monofocal intraocular lens models |
| title |
Comparison of visual performance between two aspheric monofocal intraocular lens models |
| spellingShingle |
Comparison of visual performance between two aspheric monofocal intraocular lens models Poyales, Francisco Intraocular lenses Visual acuity Quantity of vision Optical quality Visual qualit Monofocal intraocular lens Lents intraoculars Agudesa visual Àrees temàtiques de la UPC::Ciències de la visió |
| title_short |
Comparison of visual performance between two aspheric monofocal intraocular lens models |
| title_full |
Comparison of visual performance between two aspheric monofocal intraocular lens models |
| title_fullStr |
Comparison of visual performance between two aspheric monofocal intraocular lens models |
| title_full_unstemmed |
Comparison of visual performance between two aspheric monofocal intraocular lens models |
| title_sort |
Comparison of visual performance between two aspheric monofocal intraocular lens models |
| dc.creator.none.fl_str_mv |
Poyales, Francisco Garzon, Nuria Rico del Viejo Miranza, Laura Zhou, Ying Millán Garcia-Varela, M. Sagrario|||0000-0001-6950-2373 Vega Lerín, Fidel|||0000-0002-8594-0872 |
| author |
Poyales, Francisco |
| author_facet |
Poyales, Francisco Garzon, Nuria Rico del Viejo Miranza, Laura Zhou, Ying Millán Garcia-Varela, M. Sagrario|||0000-0001-6950-2373 Vega Lerín, Fidel|||0000-0002-8594-0872 |
| author_role |
author |
| author2 |
Garzon, Nuria Rico del Viejo Miranza, Laura Zhou, Ying Millán Garcia-Varela, M. Sagrario|||0000-0001-6950-2373 Vega Lerín, Fidel|||0000-0002-8594-0872 |
| author2_role |
author author author author author |
| dc.subject.none.fl_str_mv |
Intraocular lenses Visual acuity Quantity of vision Optical quality Visual qualit Monofocal intraocular lens Lents intraoculars Agudesa visual Àrees temàtiques de la UPC::Ciències de la visió |
| topic |
Intraocular lenses Visual acuity Quantity of vision Optical quality Visual qualit Monofocal intraocular lens Lents intraoculars Agudesa visual Àrees temàtiques de la UPC::Ciències de la visió |
| description |
Clinical relevance It is important to distinguish between visual acuity, optical quality and quality of vision when outcomes obtained with intraocular lenses are evaluated. These parameters, that includeobjective and subjective tests, should be assessed to obtain results that are not biased. Background To assess the difference in visual and optical quality between two monofocal intraocular lens models. Methods : This was a prospective, parallel and randomised clinical study conducted at Miranza IOA, a private clinic in Madrid, Spain. Sixty patients were implanted bilaterally, 30 per group, with two aspheric IOLs with induced spherical aberration of -0.27 µm for Group A and -0.20 µm for Group B. Visual outcomes obtained at 1 and 3 months after surgery included both uncorrected (UCVA) and corrected monocular distance visual acuity (DCVA), objective scattering index (OSI), modulation transfer function (MTF) cut-off, Strehl Ratio (SR), contrast sensitivity defocus curve (CSDC), intraocular lens spherical aberration (SA), and longitudinal chromatic aberration of the eye. Activity limitations in daily life were assessed using CatQuest-9SF questionnaire. Results There were statistically significant differences for DCVA (0.04 LogMAR; p = .008) and SR (0.03; p = .003) between groups. Outcomes related to CSDC showed statistically significant differences for vergences between -0.50 D and +1.00 D (3 mm pupil) and for vergences of 0.00 D and +0.50 D (4.5 mm pupil) between groups. Overall, Group A showed better results regarding visual and optical quality, including a lower longitudinal chromatic aberration result in comparison to Group B. Patient satisfaction evaluated with CatQuest-9SF showed that Group A achieved better outcomes, although the differences were statistically significant only for the ‘Reading text on television’ item (p = 0.027). Conclusions Both intraocular lens models showed excellent quantity of vision, optical and visual quality as well as high patient satisfaction. Despite this, the the Group A model provided slightly better outcomes than the Group B model. |
| publishDate |
2021 |
| dc.date.none.fl_str_mv |
2021 2021-12-07 2022 2022-03-17 |
| dc.type.none.fl_str_mv |
journal article http://purl.org/coar/resource_type/c_6501 AM http://purl.org/coar/version/c_ab4af688f83e57aa |
| dc.type.openaire.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| dc.identifier.none.fl_str_mv |
https://hdl.handle.net/2117/364469 https://dx.doi.org/10.1080/08164622.2021.2009737 |
| url |
https://hdl.handle.net/2117/364469 https://dx.doi.org/10.1080/08164622.2021.2009737 |
| dc.language.none.fl_str_mv |
Inglés eng |
| language_invalid_str_mv |
Inglés |
| language |
eng |
| dc.relation.none.fl_str_mv |
Agencia Estatal de Investigación http://doi.org/10.13039/501100011033 Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020 PID2020-114582RB-I00 IMPLANTES OPTICOS INTRAOCULARES CORRECTORES DE LA PRESBICIA PARA UNA COMPENSACION VISUAL PERSONALIZADA |
| dc.rights.none.fl_str_mv |
open access http://purl.org/coar/access_right/c_abf2 |
| dc.rights.openaire.fl_str_mv |
info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
open access http://purl.org/coar/access_right/c_abf2 |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
Taylor & Francis |
| publisher.none.fl_str_mv |
Taylor & Francis |
| dc.source.none.fl_str_mv |
reponame:UPCommons. Portal del coneixement obert de la UPC instname:Universitat Politècnica de Catalunya (UPC) |
| instname_str |
Universitat Politècnica de Catalunya (UPC) |
| reponame_str |
UPCommons. Portal del coneixement obert de la UPC |
| collection |
UPCommons. Portal del coneixement obert de la UPC |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869407506736873472 |
| score |
15.300719 |