A novel systematic absence of cross peaks-based 2D-COS approach for bilinear data

A novel approach to use two-dimensional correlation spectroscopy (2D-COS) to analyze bilinear data is proposed. A phenomenon called Systematic Absence of Cross Peaks (SACPs) is observed in a 2D asynchronous spectrum. Two theorems relevant to SACPs have been derived. The SACP-based 2D-COS method has...

Descripción completa

Detalles Bibliográficos
Autores: Guo, Ran, Zhang, Xin, He, Anqi, Zhang, Fei, Li, Qingbo, Zhang, Zhuoyong, Tauler, Romà, Yu, Zhenqiang, Morita, Shigeaki, Xu, Yi Zhuang, Noda, Isao, Ozaki, Yuikihiro, Wu, Jinguang
Tipo de recurso: artículo
Estado:Versión aceptada para publicación
Fecha de publicación:2019
País:España
Institución:Consejo Superior de Investigaciones Científicas (CSIC)
Repositorio:DIGITAL.CSIC. Repositorio Institucional del CSIC
OAI Identifier:oai:digital.csic.es:10261/201815
Acceso en línea:http://hdl.handle.net/10261/201815
Access Level:acceso abierto
Palabra clave:Chemometrics
2D-COS
Bilinear data
SACP
Overlapping
Chromatography
Descripción
Sumario:A novel approach to use two-dimensional correlation spectroscopy (2D-COS) to analyze bilinear data is proposed. A phenomenon called Systematic Absence of Cross Peaks (SACPs) is observed in a 2D asynchronous spectrum. Two theorems relevant to SACPs have been derived. The SACP-based 2D-COS method has been successfully applied on analyzing bilinear data from mixed samples (including one model system and two real systems). Implicit isolated peaks can be identified and assigned to different components based on characteristic pattern of SACPs even if the time-related profiles of different components are severely overlapped. Based on the results of SACPs, spectra of pure components can be retrieved. Identification of SACPs can still be achieved in the presence of artifacts. Thus, neither noise nor baseline drift can produce significant influence on the results obtained from the approach described in this paper. We have used several well-established chemometric methods, including N-Findr, VCA, and MCR with various initial settings, on two systems that can be successfully solved using the 2D-COS method. The chemometric methods mentioned above cannot provide correct spectra of pure components because of severe problem of rotational ambiguity derived from severe overlapping of the time-related profiles. Only when the information from SACPs in 2D-COS is used as additional constraints in MCR calculation, correct spectra can be obtained. That is to say, the SACP-based 2D-COS method provides intrinsic information which is crucial in the analysis of chromatographic-spectroscopic and analogous data even if the time-related profiles of different components overlap severely. © 2019 Elsevier B.V.