Modelling copper (II) liquid-liquid extraction: the system Acorga M5640-Exxsol D100-CuSO4-H2SO4
A predictive model, which consists in a set of non-linear mass action and mass balance equations solved by using a taylor-made equation-solving program, is used as a basis to predict experimentally measured distribution coefficients for the Acorga M5640-Exxsol D100-CuSO4-H2SO4 liquid-liquid extracti...
| Autores: | , , , |
|---|---|
| Formato: | artículo |
| Fecha de publicación: | 2004 |
| País: | España |
| Recursos: | Consejo Superior de Investigaciones Científicas (CSIC) |
| Repositorio: | DIGITAL.CSIC. Repositorio Institucional del CSIC |
| OAI Identifier: | oai:digital.csic.es:10261/36802 |
| Acesso em linha: | http://hdl.handle.net/10261/36802 |
| Access Level: | acceso abierto |
| Palavra-chave: | Liquid-liquid extraction Acorga M5640-EXXSOL D 100 |
| id |
ES_48c8562e4e53fb8a2767a81f6cda1d80 |
|---|---|
| oai_identifier_str |
oai:digital.csic.es:10261/36802 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Modelling copper (II) liquid-liquid extraction: the system Acorga M5640-Exxsol D100-CuSO4-H2SO4Alguacil, Francisco JoséAlonso Gámez, ManuelLópez-Delgado, AuroraNavarro, PatricioLiquid-liquid extractionAcorga M5640-EXXSOL D 100A predictive model, which consists in a set of non-linear mass action and mass balance equations solved by using a taylor-made equation-solving program, is used as a basis to predict experimentally measured distribution coefficients for the Acorga M5640-Exxsol D100-CuSO4-H2SO4 liquid-liquid extraction system at 20º C and aqueous copper concentrations in the range 0.0016-0.0032 mol l-1. The model is also used to obtain the copper loading isotherm at various equilibrium aqueous pH values.We thank to the CSIC (Spain) and USACH (Chile) for support.Peer reviewedScience Reviews Limited201120112004info:eu-repo/semantics/articlehttp://purl.org/coar/resource_type/c_6501http://hdl.handle.net/10261/36802reponame:DIGITAL.CSIC. Repositorio Institucional del CSICinstname:Consejo Superior de Investigaciones Científicas (CSIC)Ingléshttp://dx.doi.org/10.3184/0308234041640591info:eu-repo/semantics/openAccessoai:digital.csic.es:10261/368022026-05-22T06:33:51Z |
| dc.title.none.fl_str_mv |
Modelling copper (II) liquid-liquid extraction: the system Acorga M5640-Exxsol D100-CuSO4-H2SO4 |
| title |
Modelling copper (II) liquid-liquid extraction: the system Acorga M5640-Exxsol D100-CuSO4-H2SO4 |
| spellingShingle |
Modelling copper (II) liquid-liquid extraction: the system Acorga M5640-Exxsol D100-CuSO4-H2SO4 Alguacil, Francisco José Liquid-liquid extraction Acorga M5640-EXXSOL D 100 |
| title_short |
Modelling copper (II) liquid-liquid extraction: the system Acorga M5640-Exxsol D100-CuSO4-H2SO4 |
| title_full |
Modelling copper (II) liquid-liquid extraction: the system Acorga M5640-Exxsol D100-CuSO4-H2SO4 |
| title_fullStr |
Modelling copper (II) liquid-liquid extraction: the system Acorga M5640-Exxsol D100-CuSO4-H2SO4 |
| title_full_unstemmed |
Modelling copper (II) liquid-liquid extraction: the system Acorga M5640-Exxsol D100-CuSO4-H2SO4 |
| title_sort |
Modelling copper (II) liquid-liquid extraction: the system Acorga M5640-Exxsol D100-CuSO4-H2SO4 |
| dc.creator.none.fl_str_mv |
Alguacil, Francisco José Alonso Gámez, Manuel López-Delgado, Aurora Navarro, Patricio |
| author |
Alguacil, Francisco José |
| author_facet |
Alguacil, Francisco José Alonso Gámez, Manuel López-Delgado, Aurora Navarro, Patricio |
| author_role |
author |
| author2 |
Alonso Gámez, Manuel López-Delgado, Aurora Navarro, Patricio |
| author2_role |
author author author |
| dc.subject.none.fl_str_mv |
Liquid-liquid extraction Acorga M5640-EXXSOL D 100 |
| topic |
Liquid-liquid extraction Acorga M5640-EXXSOL D 100 |
| description |
A predictive model, which consists in a set of non-linear mass action and mass balance equations solved by using a taylor-made equation-solving program, is used as a basis to predict experimentally measured distribution coefficients for the Acorga M5640-Exxsol D100-CuSO4-H2SO4 liquid-liquid extraction system at 20º C and aqueous copper concentrations in the range 0.0016-0.0032 mol l-1. The model is also used to obtain the copper loading isotherm at various equilibrium aqueous pH values. |
| publishDate |
2004 |
| dc.date.none.fl_str_mv |
2004 2011 2011 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article http://purl.org/coar/resource_type/c_6501 |
| format |
article |
| dc.identifier.none.fl_str_mv |
http://hdl.handle.net/10261/36802 |
| url |
http://hdl.handle.net/10261/36802 |
| dc.language.none.fl_str_mv |
Inglés |
| language_invalid_str_mv |
Inglés |
| dc.relation.none.fl_str_mv |
http://dx.doi.org/10.3184/0308234041640591 |
| dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.publisher.none.fl_str_mv |
Science Reviews Limited |
| publisher.none.fl_str_mv |
Science Reviews Limited |
| dc.source.none.fl_str_mv |
reponame:DIGITAL.CSIC. Repositorio Institucional del CSIC instname:Consejo Superior de Investigaciones Científicas (CSIC) |
| instname_str |
Consejo Superior de Investigaciones Científicas (CSIC) |
| reponame_str |
DIGITAL.CSIC. Repositorio Institucional del CSIC |
| collection |
DIGITAL.CSIC. Repositorio Institucional del CSIC |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869407381752905728 |
| score |
15,811543 |