Dot Immunobinding Assay for the Rapid Serodetection of Scedosporium/Lomentospora in Cystic Fibrosis Patients

The detection of Scedosporium/Lomentospora is still based on non-standardized low-sensitivity culture procedures. This fact is particularly worrying in patients with cystic fibrosis (CF), where these fungi are the second most common filamentous fungi isolated, because a poor and delayed diagnosis ca...

Descripción completa

Detalles Bibliográficos
Autores: Martín Souto, Leire, Antorán Díaz, Aitziber, Areitio Beramendi, Maialen, Aparicio Fernández, Leire, Martín Gómez, María Teresa, Fernández, Roberto, Astigarraga Arribas, Egoitz, Barreda Gómez, Gabriel, Schwarz, Carsten, Rickerts, Volker, Hernando Echevarria, Fernando Luis, Rementeria Ruiz, Aitor Domingo, Buldain Garriz, Idoia, Ramírez García, Andoni
Tipo de recurso: artículo
Fecha de publicación:2023
País:España
Institución:Universidad del País Vasco
Repositorio:Addi. Archivo Digital para la Docencia y la Investigación
OAI Identifier:oai:addi.ehu.eus:10810/60198
Acceso en línea:http://hdl.handle.net/10810/60198
Access Level:acceso abierto
Palabra clave:Scedosporium
Lomentospora
cystic fibrosis
immunoassay
serological detection
antibody detection
Descripción
Sumario:The detection of Scedosporium/Lomentospora is still based on non-standardized low-sensitivity culture procedures. This fact is particularly worrying in patients with cystic fibrosis (CF), where these fungi are the second most common filamentous fungi isolated, because a poor and delayed diagnosis can worsen the prognosis of the disease. To contribute to the discovery of new diagnostic strategies, a rapid serological dot immunobinding assay (DIA) that allows the detection of serum IgG against Scedosporium/Lomentospora in less than 15 min was developed. A crude protein extract from the conidia and hyphae of Scedosporium boydii was employed as a fungal antigen. The DIA was evaluated using 303 CF serum samples (162 patients) grouped according to the detection of Scedosporium/Lomentospora in the respiratory sample by culture, obtaining a sensitivity and specificity of 90.48% and 79.30%, respectively; positive and negative predictive values of 54.81% and 96.77%, and an efficiency of 81.72%. The clinical factors associated with the results were also studied using a univariate and a multivariate analysis, which showed that Scedosporium/Lomentospora positive sputum, elevated anti-Aspergillus serum IgG and chronic Pseudomonas aeruginosa infection were significantly associated with a positive result in DIA, while Staphylococcus aureus positive sputum showed a negative association. In conclusion, the test developed can offer a complementary, rapid, simple and sensitive method to contribute to the diagnosis of Scedosporium/Lomentospora in patients with CF.