Intercomparison of Radon Flux Monitors at Low and at High Radium Content Areas under Field Conditions
Interlaboratory exercises are a good tool to compare the response of different systems to the same quantity and to identify possible inconsistencies between them. One of the main goals of the EMPIR 19ENV01 traceRadon project is to harmonize radon flux measurements based on different systems and meth...
| Autores: | , , , , , , , , , , , , , |
|---|---|
| Tipo de recurso: | artículo |
| Fecha de publicación: | 2022 |
| País: | España |
| Institución: | Universitat Politècnica de Catalunya (UPC) |
| Repositorio: | UPCommons. Portal del coneixement obert de la UPC |
| Idioma: | inglés |
| OAI Identifier: | oai:upcommons.upc.edu:2117/366231 |
| Acceso en línea: | https://hdl.handle.net/2117/366231 https://dx.doi.org/10.3390/ijerph19074213 |
| Access Level: | acceso abierto |
| Palabra clave: | Radon Exhalation TraceRadon Proficiency test Interlaboratory comparison Radó Àrees temàtiques de la UPC::Física |
| id |
ES_4219f4f7dc8bf33997b50d8cdaf53ef1 |
|---|---|
| oai_identifier_str |
oai:upcommons.upc.edu:2117/366231 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Intercomparison of Radon Flux Monitors at Low and at High Radium Content Areas under Field ConditionsRábago, DanielQuindós, LuisVargas Drechsler, Arturo|||0000-0002-2576-9671Sainz, CarlosRadulescu, IleanaRazvan Ioan, MihailCardellini, FrancescoCapogni, MarcoRizzo, AlessandroCelaya, SantiagoFuente, IsmaelFuente, MartaGrossi, Claudia|||0000-0001-6678-4440Rodríguez, MariaRadonExhalationTraceRadonProficiency testInterlaboratory comparisonRadóÀrees temàtiques de la UPC::FísicaInterlaboratory exercises are a good tool to compare the response of different systems to the same quantity and to identify possible inconsistencies between them. One of the main goals of the EMPIR 19ENV01 traceRadon project is to harmonize radon flux measurements based on different systems and methodologies. In the framework of the traceRadon Project, two radon flux intercomparison campaigns were carried out in October 2021 at high and at low radon source areas. Four institutions participated in the field intercomparison exercises with their own systems. Every system was based on a specific radon monitor (diffusion or pump mode) and an accumulation chamber (with manual or automatic opening). Radon fluxes were calculated by each participant using both exponential and linear fittings of the radon activity concentration measured over time within the accumulation chambers. The results of this study show mainly: (i) the exponential approach is not advisable due to the variability of the radon flux and the leakage of the systems during long-time measurements; (ii) the linear approach should be applied to minimize the measurement period in agreement with the time response and sensitivity of the monitors; (iii) radon flux measured at high radon source areas (radium content of about 800 Bq kg-1) risks being underestimated because of the influence of advective effects; (iv) radon flux measured at low radon source areas (radium content of about 30 Bq kg-1) may present large uncertainties if sensitive radon monitors with pump mode are not used.Peer Reviewed20222022-04-0120222022-04-22journal articlehttp://purl.org/coar/resource_type/c_6501VoRhttp://purl.org/coar/version/c_970fb48d4fbd8a85info:eu-repo/semantics/articleapplication/pdfhttps://hdl.handle.net/2117/366231https://dx.doi.org/10.3390/ijerph19074213reponame:UPCommons. Portal del coneixement obert de la UPCinstname:Universitat Politècnica de Catalunya (UPC)Inglésengopen accesshttp://purl.org/coar/access_right/c_abf2Attribution 4.0 International (CC BY 4.0)https://creativecommons.org/licenses/by/4.0/info:eu-repo/semantics/openAccessoai:upcommons.upc.edu:2117/3662312026-05-27T15:37:01Z |
| dc.title.none.fl_str_mv |
Intercomparison of Radon Flux Monitors at Low and at High Radium Content Areas under Field Conditions |
| title |
Intercomparison of Radon Flux Monitors at Low and at High Radium Content Areas under Field Conditions |
| spellingShingle |
Intercomparison of Radon Flux Monitors at Low and at High Radium Content Areas under Field Conditions Rábago, Daniel Radon Exhalation TraceRadon Proficiency test Interlaboratory comparison Radó Àrees temàtiques de la UPC::Física |
| title_short |
Intercomparison of Radon Flux Monitors at Low and at High Radium Content Areas under Field Conditions |
| title_full |
Intercomparison of Radon Flux Monitors at Low and at High Radium Content Areas under Field Conditions |
| title_fullStr |
Intercomparison of Radon Flux Monitors at Low and at High Radium Content Areas under Field Conditions |
| title_full_unstemmed |
Intercomparison of Radon Flux Monitors at Low and at High Radium Content Areas under Field Conditions |
| title_sort |
Intercomparison of Radon Flux Monitors at Low and at High Radium Content Areas under Field Conditions |
| dc.creator.none.fl_str_mv |
Rábago, Daniel Quindós, Luis Vargas Drechsler, Arturo|||0000-0002-2576-9671 Sainz, Carlos Radulescu, Ileana Razvan Ioan, Mihail Cardellini, Francesco Capogni, Marco Rizzo, Alessandro Celaya, Santiago Fuente, Ismael Fuente, Marta Grossi, Claudia|||0000-0001-6678-4440 Rodríguez, Maria |
| author |
Rábago, Daniel |
| author_facet |
Rábago, Daniel Quindós, Luis Vargas Drechsler, Arturo|||0000-0002-2576-9671 Sainz, Carlos Radulescu, Ileana Razvan Ioan, Mihail Cardellini, Francesco Capogni, Marco Rizzo, Alessandro Celaya, Santiago Fuente, Ismael Fuente, Marta Grossi, Claudia|||0000-0001-6678-4440 Rodríguez, Maria |
| author_role |
author |
| author2 |
Quindós, Luis Vargas Drechsler, Arturo|||0000-0002-2576-9671 Sainz, Carlos Radulescu, Ileana Razvan Ioan, Mihail Cardellini, Francesco Capogni, Marco Rizzo, Alessandro Celaya, Santiago Fuente, Ismael Fuente, Marta Grossi, Claudia|||0000-0001-6678-4440 Rodríguez, Maria |
| author2_role |
author author author author author author author author author author author author author |
| dc.subject.none.fl_str_mv |
Radon Exhalation TraceRadon Proficiency test Interlaboratory comparison Radó Àrees temàtiques de la UPC::Física |
| topic |
Radon Exhalation TraceRadon Proficiency test Interlaboratory comparison Radó Àrees temàtiques de la UPC::Física |
| description |
Interlaboratory exercises are a good tool to compare the response of different systems to the same quantity and to identify possible inconsistencies between them. One of the main goals of the EMPIR 19ENV01 traceRadon project is to harmonize radon flux measurements based on different systems and methodologies. In the framework of the traceRadon Project, two radon flux intercomparison campaigns were carried out in October 2021 at high and at low radon source areas. Four institutions participated in the field intercomparison exercises with their own systems. Every system was based on a specific radon monitor (diffusion or pump mode) and an accumulation chamber (with manual or automatic opening). Radon fluxes were calculated by each participant using both exponential and linear fittings of the radon activity concentration measured over time within the accumulation chambers. The results of this study show mainly: (i) the exponential approach is not advisable due to the variability of the radon flux and the leakage of the systems during long-time measurements; (ii) the linear approach should be applied to minimize the measurement period in agreement with the time response and sensitivity of the monitors; (iii) radon flux measured at high radon source areas (radium content of about 800 Bq kg-1) risks being underestimated because of the influence of advective effects; (iv) radon flux measured at low radon source areas (radium content of about 30 Bq kg-1) may present large uncertainties if sensitive radon monitors with pump mode are not used. |
| publishDate |
2022 |
| dc.date.none.fl_str_mv |
2022 2022-04-01 2022 2022-04-22 |
| dc.type.none.fl_str_mv |
journal article http://purl.org/coar/resource_type/c_6501 VoR http://purl.org/coar/version/c_970fb48d4fbd8a85 |
| dc.type.openaire.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| dc.identifier.none.fl_str_mv |
https://hdl.handle.net/2117/366231 https://dx.doi.org/10.3390/ijerph19074213 |
| url |
https://hdl.handle.net/2117/366231 https://dx.doi.org/10.3390/ijerph19074213 |
| dc.language.none.fl_str_mv |
Inglés eng |
| language_invalid_str_mv |
Inglés |
| language |
eng |
| dc.rights.none.fl_str_mv |
open access http://purl.org/coar/access_right/c_abf2 Attribution 4.0 International (CC BY 4.0) https://creativecommons.org/licenses/by/4.0/ |
| dc.rights.openaire.fl_str_mv |
info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
open access http://purl.org/coar/access_right/c_abf2 Attribution 4.0 International (CC BY 4.0) https://creativecommons.org/licenses/by/4.0/ |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.source.none.fl_str_mv |
reponame:UPCommons. Portal del coneixement obert de la UPC instname:Universitat Politècnica de Catalunya (UPC) |
| instname_str |
Universitat Politècnica de Catalunya (UPC) |
| reponame_str |
UPCommons. Portal del coneixement obert de la UPC |
| collection |
UPCommons. Portal del coneixement obert de la UPC |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869406900846592000 |
| score |