Visual Quality and Symptomatology Following Implantation of a Non-Diffractive Extended Depth-of-Focus Intraocular Lens

Background/Objectives: This study aimed to evaluate the visual quality and symptomatology of a non-diffractive extended depth-of-focus (EDoF) intraocular lens (IOL), the Elon 877PEY (Medicontur, Zsámbék, Hungary), three months after implantation. Methods: A cross-sectional case series study was cond...

Descripción completa

Detalles Bibliográficos
Autores: Cano Ortiz, Antonio, Sánchez Ventosa, Álvaro, González Cruces, Timoteo, Villalba González, Marta, Aguilar Salazar, Francisco Javier, Prados Carmona, Juan J., Carpena Torres, Carlos, Carracedo Rodríguez, Juan Gonzalo, Villarrubia, Alberto
Tipo de recurso: artículo
Fecha de publicación:2025
País:España
Institución:Universidad Complutense de Madrid (UCM)
Repositorio:Docta Complutense
Idioma:inglés
OAI Identifier:oai:docta.ucm.es:20.500.14352/122853
Acceso en línea:https://hdl.handle.net/20.500.14352/122853
Access Level:acceso abierto
Palabra clave:617.7-089.243
Extended range
EDOF
Defocus curve
Visual acuity
Contrast sensitivity
Óptica y optometría
2209 Óptica
Descripción
Sumario:Background/Objectives: This study aimed to evaluate the visual quality and symptomatology of a non-diffractive extended depth-of-focus (EDoF) intraocular lens (IOL), the Elon 877PEY (Medicontur, Zsámbék, Hungary), three months after implantation. Methods: A cross-sectional case series study was conducted, with measurements taken three months post-implantation of the Elon IOL. A total of 56 implanted eyes from 28 patients (mean age: 64.5 ± 9.5 years) were included in the statistical analysis. The variables analyzed to assess the effectiveness of the Elon IOL included high-contrast visual acuity, contrast sensitivity, the defocus curve, and visual symptoms. Results: Three months after implantation, the mean residual sphere was 0.00 ± 0.33 D, while the mean residual cylinder was −0.25 ± 0.41 D. Without correction, patients achieved monocular decimal visual acuity values of 0.94 ± 0.26 for distance, 0.79 ± 0.17 for intermediate, and 0.58 ± 0.15 for near vision. The mean uncorrected contrast sensitivity was 1.61 ± 0.15 log. The defocus curve showed visual acuity exceeding 0.80 decimal (0.10 logMAR) over a 2.00 D range and above 0.63 decimal (0.20 logMAR) over a 2.50 D range. The most frequently reported symptoms, with mild severity and bothersomeness, were glare, starbursts, halos, and focusing difficulties. Conclusions: Patients implanted with the Elon IOL achieved satisfactory visual quality at all distances, comparable to outcomes reported for other EDoF IOLs in the scientific literature.