Local multifrequency impedance changes after radiofrequency ablation in human atria: potential use for tissue characterization

Background: Local impedance (LI) mapping provides additional tissue characterization of the atria substrate. Measuring LI at different current frequencies has the advantage of exploring intra- and extra-cellular compartments and may add useful information about tissue integrity. The objective of thi...

Descripción completa

Detalles Bibliográficos
Autores: Amorós Figueras, Gerard, Moreno Weidmann, Zoraida, Méndez Zurita, Francisco, Soriano Amores, Marc, Bragós Bardia, Ramon|||0000-0002-1373-1588, Rosell Ferrer, Francisco Javier|||0000-0002-9691-328X, Guerra Ramos, José Mª
Tipo de recurso: artículo
Fecha de publicación:2025
País:España
Institución:Universitat Politècnica de Catalunya (UPC)
Repositorio:UPCommons. Portal del coneixement obert de la UPC
Idioma:inglés
OAI Identifier:oai:upcommons.upc.edu:2117/450165
Acceso en línea:https://hdl.handle.net/2117/450165
https://dx.doi.org/10.3389/fcvm.2025.1668533
Access Level:acceso abierto
Palabra clave:Local multifrequency impedance
Radiofrequency ablation
Electrophysiology
Tissue characterization
Lesion assessment
Àrees temàtiques de la UPC::Enginyeria electrònica
Descripción
Sumario:Background: Local impedance (LI) mapping provides additional tissue characterization of the atria substrate. Measuring LI at different current frequencies has the advantage of exploring intra- and extra-cellular compartments and may add useful information about tissue integrity. The objective of this study was to characterize the changes in local multifrequency impedance (LMI) after radiofrequency ablation in human atrial tissue. Methods: In fifteen patients undergoing catheter ablation of atrial arrhythmias, we constructed a baseline high-density electroanatomical map (EAM) and measured the LMI (1–1,000 kHz) at fifty sites around the cava veins using the QDOT or Smarttouch electrocatheter. Then a point-by-point pulmonary vein isolation procedure was performed using radiofrequency energy in a temperature controlled mode (90W for 4 s for QDOT/30W for 30 s for Smarttouch). After confirming the PVI fifty additional LMI recordings per patient were performed around the initial sites. We performed an offline analysis to compare the values of bipolar voltage and LMI of blood, pre- and post-ablated tissue. We also analyzed the cardiac cycle changes of LMI and the effects of catheter orientation to the LMI, contact force and bipolar voltage. Results: A total of 641 pre-ablated and 190 post-ablated sites were studied from all patients. Blood pool, healthy and post-ablated myocardium presented distinctive LMI signatures (ZPRE¿=¿110¿±¿15 O vs. ZPOST¿=¿90¿±¿10 O vs. ZBLOOD¿=¿90¿±¿8 O; p¿<¿0.001). LMI cyclic changes showed an inverse relationship with the contact force, and these were more attenuated in the post-ablated tissue (p¿<¿0.001). Conclusions: LMI can differentiate pre- from post-ablated tissue in a cohort of patients submitted to RF ablations. This new tool could be of potential clinical applicability for the characterization of the atrial substrate and to monitor lesion quality to perform durable ablation lesions.