Nondetection of SARS-CoV-2 on high-touch surfaces of public areas next to COVID-19 hospitalization units
We studied the contamination with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and the bacterial load of high-touch surfaces located in public areas next to coronavirus disease (COVID-19) hospitalization units. Ninety-two samples were obtained from 46 different high-touch surfaces: 3...
| Autores: | , , , , , , |
|---|---|
| Tipo de recurso: | artículo |
| Estado: | Versión publicada |
| Fecha de publicación: | 2021 |
| País: | España |
| Institución: | Universidad de Barcelona |
| Repositorio: | Dipòsit Digital de la UB |
| OAI Identifier: | oai:diposit.ub.edu:2445/178513 |
| Acceso en línea: | https://hdl.handle.net/2445/178513 |
| Access Level: | acceso abierto |
| Palabra clave: | COVID-19 SARS-CoV-2 |
| Sumario: | We studied the contamination with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and the bacterial load of high-touch surfaces located in public areas next to coronavirus disease (COVID-19) hospitalization units. Ninety-two samples were obtained from 46 different high-touch surfaces: 36 sites next to COVID-19 hospitalization units and 10 sites in the cabins of the public elevators. SARS-CoV-2 was not detected at any site, despite high bacterial loads suggested that the studied sites had been frequently touched prior to the sampling. |
|---|