Microdosimetry in low energy proton beam at therapeutic-equivalent fluence rate with silicon 3D-cylindrical microdetectors

In this work we show the first microdosimetry measurements on a low energy proton beam with therapeutic-equivalent fluence rates by using the second generation of 3D-cylindrical microdetectors. The sensors belong to an improved version of a novel silicon-based 3D-microdetector design with electrodes...

Descripción completa

Detalles Bibliográficos
Autores: Guardiola, Consuelo, Bachiller Perea, Diana, Prieto Pena, Juan, Jiménez-Ramos, María del Carmen, García López, Javier, Esnault, C., Fleta, Celeste, Quirion, David, Gómez Rodríguez, Faustino
Tipo de recurso: artículo
Fecha de publicación:2021
País:España
Institución:Universidad de Santiago de Compostela (USC)
Repositorio:Minerva. Repositorio Institucional de la Universidad de Santiago de Compostela
Idioma:inglés
OAI Identifier:oai:minerva.usc.gal:10347/32068
Acceso en línea:http://hdl.handle.net/10347/32068
Access Level:acceso abierto
Palabra clave:Investigación
id ES_3afe6c6a40fa2db3e8bbaf413579b6bf
oai_identifier_str oai:minerva.usc.gal:10347/32068
network_acronym_str ES
network_name_str España
repository_id_str
spelling Microdosimetry in low energy proton beam at therapeutic-equivalent fluence rate with silicon 3D-cylindrical microdetectorsGuardiola, ConsueloBachiller Perea, DianaPrieto Pena, JuanJiménez-Ramos, María del CarmenGarcía López, JavierEsnault, C.Fleta, CelesteQuirion, DavidGómez Rodríguez, FaustinoInvestigaciónIn this work we show the first microdosimetry measurements on a low energy proton beam with therapeutic-equivalent fluence rates by using the second generation of 3D-cylindrical microdetectors. The sensors belong to an improved version of a novel silicon-based 3D-microdetector design with electrodes etched inside silicon, which were manufactured at the National Microelectronics Centre (IMB-CNM, CSIC) in Spain. A new microtechnology has been employed using quasi-toroid electrodes of 25 μm diameter and a depth of 20 μm within the silicon bulk, resulting in a well-defined cylindrical radiation sensitive volume. These detectors were tested at the 18 MeV proton beamline of the cyclotron at the National Accelerator Centre (CNA, Spain). They were assembled into an in-house low-noise readout electronics to assess their performance at a therapeutic-equivalent fluence rate. Microdosimetry spectra of lineal energy were recorded at several proton energies starting from 18 MeV by adding 50 μm thick tungsten foils gradually at the exit-window of the cyclotron external beamline, which corresponds to different depths along the Bragg curve. The experimental y¯F values in silicon cover from (5.7 ± 0.9) to (8.5 ± 0.4) keV μm-1 in the entrance to (27.4 ± 2.3) keV μm-1 in the distal edge. Pulse height energy spectra were crosschecked with Monte Carlo simulations and an excellent agreement was obtained. This work demonstrates the capability of the second generation 3D-microdetectors to assess accurate microdosimetric distributions at fluence rates as high as those used in clinical centers in proton therapy.Institute of Physics Publishing20212021-06-0120212021-06-01journal articlehttp://purl.org/coar/resource_type/c_6501VoRhttp://purl.org/coar/version/c_970fb48d4fbd8a85info:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10347/32068reponame:Minerva. Repositorio Institucional de la Universidad de Santiago de Compostelainstname:Universidad de Santiago de Compostela (USC)Inglésengopen accesshttp://purl.org/coar/access_right/c_abf2OPEN ACCESS. CC BY 4.0 DEED Atribución 4.0 Internacional © 2021 Institute of Physics and Engineering in Medicinehttp://creativecommons.org/licenses/by/4.0/deed.esinfo:eu-repo/semantics/openAccessoai:minerva.usc.gal:10347/320682026-06-15T12:47:27Z
dc.title.none.fl_str_mv Microdosimetry in low energy proton beam at therapeutic-equivalent fluence rate with silicon 3D-cylindrical microdetectors
title Microdosimetry in low energy proton beam at therapeutic-equivalent fluence rate with silicon 3D-cylindrical microdetectors
spellingShingle Microdosimetry in low energy proton beam at therapeutic-equivalent fluence rate with silicon 3D-cylindrical microdetectors
Guardiola, Consuelo
Investigación
title_short Microdosimetry in low energy proton beam at therapeutic-equivalent fluence rate with silicon 3D-cylindrical microdetectors
title_full Microdosimetry in low energy proton beam at therapeutic-equivalent fluence rate with silicon 3D-cylindrical microdetectors
title_fullStr Microdosimetry in low energy proton beam at therapeutic-equivalent fluence rate with silicon 3D-cylindrical microdetectors
title_full_unstemmed Microdosimetry in low energy proton beam at therapeutic-equivalent fluence rate with silicon 3D-cylindrical microdetectors
title_sort Microdosimetry in low energy proton beam at therapeutic-equivalent fluence rate with silicon 3D-cylindrical microdetectors
dc.creator.none.fl_str_mv Guardiola, Consuelo
Bachiller Perea, Diana
Prieto Pena, Juan
Jiménez-Ramos, María del Carmen
García López, Javier
Esnault, C.
Fleta, Celeste
Quirion, David
Gómez Rodríguez, Faustino
author Guardiola, Consuelo
author_facet Guardiola, Consuelo
Bachiller Perea, Diana
Prieto Pena, Juan
Jiménez-Ramos, María del Carmen
García López, Javier
Esnault, C.
Fleta, Celeste
Quirion, David
Gómez Rodríguez, Faustino
author_role author
author2 Bachiller Perea, Diana
Prieto Pena, Juan
Jiménez-Ramos, María del Carmen
García López, Javier
Esnault, C.
Fleta, Celeste
Quirion, David
Gómez Rodríguez, Faustino
author2_role author
author
author
author
author
author
author
author
dc.contributor.none.fl_str_mv
dc.subject.none.fl_str_mv Investigación
topic Investigación
description In this work we show the first microdosimetry measurements on a low energy proton beam with therapeutic-equivalent fluence rates by using the second generation of 3D-cylindrical microdetectors. The sensors belong to an improved version of a novel silicon-based 3D-microdetector design with electrodes etched inside silicon, which were manufactured at the National Microelectronics Centre (IMB-CNM, CSIC) in Spain. A new microtechnology has been employed using quasi-toroid electrodes of 25 μm diameter and a depth of 20 μm within the silicon bulk, resulting in a well-defined cylindrical radiation sensitive volume. These detectors were tested at the 18 MeV proton beamline of the cyclotron at the National Accelerator Centre (CNA, Spain). They were assembled into an in-house low-noise readout electronics to assess their performance at a therapeutic-equivalent fluence rate. Microdosimetry spectra of lineal energy were recorded at several proton energies starting from 18 MeV by adding 50 μm thick tungsten foils gradually at the exit-window of the cyclotron external beamline, which corresponds to different depths along the Bragg curve. The experimental y¯F values in silicon cover from (5.7 ± 0.9) to (8.5 ± 0.4) keV μm-1 in the entrance to (27.4 ± 2.3) keV μm-1 in the distal edge. Pulse height energy spectra were crosschecked with Monte Carlo simulations and an excellent agreement was obtained. This work demonstrates the capability of the second generation 3D-microdetectors to assess accurate microdosimetric distributions at fluence rates as high as those used in clinical centers in proton therapy.
publishDate 2021
dc.date.none.fl_str_mv 2021
2021-06-01
2021
2021-06-01
dc.type.none.fl_str_mv journal article
http://purl.org/coar/resource_type/c_6501
VoR
http://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.openaire.fl_str_mv info:eu-repo/semantics/article
format article
dc.identifier.none.fl_str_mv http://hdl.handle.net/10347/32068
url http://hdl.handle.net/10347/32068
dc.language.none.fl_str_mv Inglés
eng
language_invalid_str_mv Inglés
language eng
dc.rights.none.fl_str_mv open access
http://purl.org/coar/access_right/c_abf2
http://creativecommons.org/licenses/by/4.0/deed.es
dc.rights.openaire.fl_str_mv info:eu-repo/semantics/openAccess
rights_invalid_str_mv open access
http://purl.org/coar/access_right/c_abf2
http://creativecommons.org/licenses/by/4.0/deed.es
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Institute of Physics Publishing
publisher.none.fl_str_mv Institute of Physics Publishing
dc.source.none.fl_str_mv reponame:Minerva. Repositorio Institucional de la Universidad de Santiago de Compostela
instname:Universidad de Santiago de Compostela (USC)
instname_str Universidad de Santiago de Compostela (USC)
reponame_str Minerva. Repositorio Institucional de la Universidad de Santiago de Compostela
collection Minerva. Repositorio Institucional de la Universidad de Santiago de Compostela
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869406277672632320
score 15.81155