Fractional Order PID Design for a Proton Exchange Membrane Fuel Cell System Using an Extended Grey Wolf Optimizer
This paper presents a comparison of optimizers for tuning a fractional-order proportional-integral-derivative (FOPID) and proportional-integral-derivative (PID) controllers, which were applied to a DC/DC boost converter. Grey wolf optimizer (GWO) and extended grey wolf optimizer (EGWO) have been cho...
| Autores: | , , , , |
|---|---|
| Tipo de recurso: | artículo |
| Fecha de publicación: | 2022 |
| País: | España |
| Institución: | Universidad del País Vasco |
| Repositorio: | Addi. Archivo Digital para la Docencia y la Investigación |
| OAI Identifier: | oai:addi.ehu.eus:10810/56172 |
| Acceso en línea: | http://hdl.handle.net/10810/56172 |
| Access Level: | acceso abierto |
| Palabra clave: | extended grey wolf optimizer grey wolf optimizer fractional order proportional integral derivative proton exchange membrane fuel cell DC/DC boost converter |
| Sumario: | This paper presents a comparison of optimizers for tuning a fractional-order proportional-integral-derivative (FOPID) and proportional-integral-derivative (PID) controllers, which were applied to a DC/DC boost converter. Grey wolf optimizer (GWO) and extended grey wolf optimizer (EGWO) have been chosen to achieve suitable parameters. This strategy aims to improve and optimize a proton exchange membrane fuel cell (PEMFC) output power quality through its link with the boost converter. The model and controllers have been implemented in a MATLAB/SIMULINK environment. This study has been conducted to compare the effectiveness of the proposed controllers in the transient, accuracy in tracking the reference current, steady-state, dynamic responses, overshoots, and response time. Results showed that the combination EGWO-FOPID had significant advantages over the rest of the optimized controllers |
|---|