Impact of the dosimetry approach on the resulting 90Y radioembolization planned absorbed doses based on 99mTc-MAA SPEC T-CT: is there agreement between dosimetry methods?

Background: Prior radioembolization, a simulation using 99mTc-macroaggregated albumin as 90Y-microspheres surrogate is performed. Gamma scintigraphy images (planar, SPECT, or SPECT-CT) are acquired to evaluate intrahepatic 90Y-microspheres distribution and detect possible extrahepatic and lung shunt...

ver descrição completa

Detalhes bibliográficos
Autores: Morán-Velasco, V. (Verónica)|||/items/cd495627-9489-481f-9e8a-d2e89b5867d9, Prieto-Azcárate, E. (Elena)|||/items/98983a2a-3ce1-471b-8174-68cd47fc9fcb, Sancho, L. (Lidia)|||/items/b270fea5-a3de-44f8-8ff1-1218b8ace958, Rodriguez-Fraile, M. (Macarena)|||/items/431e1418-ba87-4b39-828b-55ba49df44f5, Soria, L. (Leticia)|||/items/971159ec-c420-41c5-8873-1597bca8bd1b, Zubiria, A. (Arantxa)|||/items/58d77887-d4ce-4137-aef9-43de5dfcad3f, Marti-Climent, J.M. (Josep María)|||/items/dfc511a4-aa92-44b5-8624-17b03d0f3466
Formato: artículo
Fecha de publicación:2020
País:España
Recursos:Universidad de Navarra
Repositorio:Dadun. Depósito Académico Digital de la Universidad de Navarra
Idioma:inglés
OAI Identifier:oai:dadun.unav.edu:10171/66342
Acesso em linha:https://hdl.handle.net/10171/66342
Access Level:acceso abierto
Palavra-chave:90Y-Microspheres
99mTc-MAA
Radioembolization
Predictive dosimetry
Partition model
Multi-tumor partition model
3D voxel dosimetry
Local deposition method
Dose point kernel
Descrição
Resumo:Background: Prior radioembolization, a simulation using 99mTc-macroaggregated albumin as 90Y-microspheres surrogate is performed. Gamma scintigraphy images (planar, SPECT, or SPECT-CT) are acquired to evaluate intrahepatic 90Y-microspheres distribution and detect possible extrahepatic and lung shunting. These images may be used for pre-treatment dosimetry evaluation to calculate the 90Y activity that would get an optimal tumor response while sparing healthy tissues. Several dosimetry methods are available, but there is still no consensus on the best methodology to calculate absorbed doses. The goal of this study was to retrospectively evaluate the impact of using different dosimetry approaches on the resulting 90Y-radioembolization pre-treatment absorbed dose evaluation based on 99mTc-MAA images. Methods: Absorbed doses within volumes of interest resulting from partition model (PM) and 3D voxel dosimetry methods (3D-VDM) (dose-point kernel convolution and local deposition method) were evaluated. Additionally, a new “Multi-tumor Partition Model” (MTPM) was developed. The differences among dosimetry approaches were evaluated in terms of mean absorbed dose and dose volume histograms within the volumes of interest. Results: Differences in mean absorbed dose among dosimetry methods are higher in tumor volumes than in non-tumoral ones. The differences between MTPM and both 3D-VDM were substantially lower than those observed between PM and any 3D-VDM. A poor correlation and concordance were found between PM and the other studied dosimetry approaches. DVH obtained from either 3D-VDM are pretty similar in both healthy liver and individual tumors. Although no relevant global differences, in terms of absorbed dose in Gy, between both 3D-VDM were found, important voxel-by-voxel differences have been observed. Conclusions: Significant differences among the studied dosimetry approaches for 90Y-radioembolization treatments exist. Differences do not yield a substantial impact in treatment planning for healthy tissue but they do for tumoral liver. An individual segmentation and evaluation of the tumors is essential. In patients with multiple tumors, the application of PM is not optimal and the 3D-VDM or the new MTPM are suggested instead. If a 3D-VDM method is not available, MTPM is the best option. Furthermore, both 3D-VDM approaches may be indistinctly used.