Variations in radon dosimetry under different assessment approaches in the Altamira Cave

The atmosphere of caves is a special environment where it is necessary to take into account some particular characteristics when assessing the radon dose. The equilibrium factor (F) between radon and its progeny, and especially its unattached fraction ( fp), is a key parameter in radon dose evaluati...

ver descrição completa

Detalhes bibliográficos
Autores: Sainz Fernández, Carlos|||0000-0003-2029-4512, Rábago Gómez, Daniel|||0000-0002-2285-8767, Fernández López, Enrique, Quindós López, Jorge, Quindós López, Luis, Fernández Villar, Alicia|||0000-0001-5171-3252, Fuente Merino, Ismael|||0000-0001-7757-8511, Arteche, Jose Luis, Quindós Poncela, Luis Santiago|||0000-0002-1049-6922, Celaya Gonzalez, Santiago
Formato: artículo
Fecha de publicación:2020
País:España
Recursos:Universidad de Cantabria (UC)
Repositorio:UCrea Repositorio Abierto de la Universidad de Cantabria
Idioma:inglés
OAI Identifier:oai:repositorio.unican.es:10902/18373
Acesso em linha:http://hdl.handle.net/10902/18373
Access Level:acceso abierto
Palavra-chave:Radon Dose
Progeny
Dose Conversion Factor
Cave
Altamira
id ES_2d1b56dc6cc8f5871630b4d5bb402dc9
oai_identifier_str oai:repositorio.unican.es:10902/18373
network_acronym_str ES
network_name_str España
repository_id_str
spelling Variations in radon dosimetry under different assessment approaches in the Altamira CaveSainz Fernández, Carlos|||0000-0003-2029-4512Rábago Gómez, Daniel|||0000-0002-2285-8767 Fernández López, EnriqueQuindós López, JorgeQuindós López, LuisFernández Villar, Alicia|||0000-0001-5171-3252Fuente Merino, Ismael|||0000-0001-7757-8511Arteche, Jose LuisQuindós Poncela, Luis Santiago|||0000-0002-1049-6922Celaya Gonzalez, SantiagoRadon DoseProgenyDose Conversion FactorCaveAltamiraThe atmosphere of caves is a special environment where it is necessary to take into account some particular characteristics when assessing the radon dose. The equilibrium factor (F) between radon and its progeny, and especially its unattached fraction ( fp), is a key parameter in radon dose evaluation. In order to consider the specific features of the atmosphere in the Altamira Cave, the radon and particle concentrations have been measured. The mean annual radon concentration inside the cave over the period 2013?2019 is around 3500 Bq m?3 with a standard deviation of 1833 Bq m?3 and this exhibits seasonal variations. This value surpasses all international (WHO, IAEA, ICRP) upper action and reference levels (occupational and non-occupational). Dose rate levels expressed in ?Sv h?1 were estimated for four different equilibrium scenarios between radon and its progeny 218Po, 214Pb, 214Bi and 214Po. The most recent dose conversion factors have been used and the contribution made to the dose by the unattached fraction of radon progeny fp has been also assessed from the particle concentration. The results suggest that the mean annual dose levels show variations of up to 500% due to the range of F and the fp considered in this study. Given the high radon concentrations usually found in show caves, the best way to reduce this variability and its associated uncertainty in dose assessment is to conduct specific studies aimed at determining both F and fp.This work was supported by the Ministry of Education, Culture and Sport of Spain (MECD) (grant number J180052) under the Project ‘Servicio de control y seguimiento de las condiciones ambientales y del biodeterioro de la Cueva de Altamira’, and The Cantabrian International Institute for Prehistoric Research (IIIPC).IOP PublishingUniversidad de Cantabria20202020-06-01journal articlehttp://purl.org/coar/resource_type/c_6501NAhttp://purl.org/coar/version/c_be7fb7dd8ff6fe43info:eu-repo/semantics/articlehttp://hdl.handle.net/10902/18373J. Radiol. Prot. 40 (2020) 367-380reponame:UCrea Repositorio Abierto de la Universidad de Cantabriainstname:Universidad de Cantabria (UC)Inglésengopen accesshttp://purl.org/coar/access_right/c_abf2info:eu-repo/semantics/openAccessoai:repositorio.unican.es:10902/183732026-06-02T12:39:31Z
dc.title.none.fl_str_mv Variations in radon dosimetry under different assessment approaches in the Altamira Cave
title Variations in radon dosimetry under different assessment approaches in the Altamira Cave
spellingShingle Variations in radon dosimetry under different assessment approaches in the Altamira Cave
Sainz Fernández, Carlos|||0000-0003-2029-4512
Radon Dose
Progeny
Dose Conversion Factor
Cave
Altamira
title_short Variations in radon dosimetry under different assessment approaches in the Altamira Cave
title_full Variations in radon dosimetry under different assessment approaches in the Altamira Cave
title_fullStr Variations in radon dosimetry under different assessment approaches in the Altamira Cave
title_full_unstemmed Variations in radon dosimetry under different assessment approaches in the Altamira Cave
title_sort Variations in radon dosimetry under different assessment approaches in the Altamira Cave
dc.creator.none.fl_str_mv Sainz Fernández, Carlos|||0000-0003-2029-4512
Rábago Gómez, Daniel|||0000-0002-2285-8767
Fernández López, Enrique
Quindós López, Jorge
Quindós López, Luis
Fernández Villar, Alicia|||0000-0001-5171-3252
Fuente Merino, Ismael|||0000-0001-7757-8511
Arteche, Jose Luis
Quindós Poncela, Luis Santiago|||0000-0002-1049-6922
Celaya Gonzalez, Santiago
author Sainz Fernández, Carlos|||0000-0003-2029-4512
author_facet Sainz Fernández, Carlos|||0000-0003-2029-4512
Rábago Gómez, Daniel|||0000-0002-2285-8767
Fernández López, Enrique
Quindós López, Jorge
Quindós López, Luis
Fernández Villar, Alicia|||0000-0001-5171-3252
Fuente Merino, Ismael|||0000-0001-7757-8511
Arteche, Jose Luis
Quindós Poncela, Luis Santiago|||0000-0002-1049-6922
Celaya Gonzalez, Santiago
author_role author
author2 Rábago Gómez, Daniel|||0000-0002-2285-8767
Fernández López, Enrique
Quindós López, Jorge
Quindós López, Luis
Fernández Villar, Alicia|||0000-0001-5171-3252
Fuente Merino, Ismael|||0000-0001-7757-8511
Arteche, Jose Luis
Quindós Poncela, Luis Santiago|||0000-0002-1049-6922
Celaya Gonzalez, Santiago
author2_role author
author
author
author
author
author
author
author
author
dc.contributor.none.fl_str_mv Universidad de Cantabria
dc.subject.none.fl_str_mv Radon Dose
Progeny
Dose Conversion Factor
Cave
Altamira
topic Radon Dose
Progeny
Dose Conversion Factor
Cave
Altamira
description The atmosphere of caves is a special environment where it is necessary to take into account some particular characteristics when assessing the radon dose. The equilibrium factor (F) between radon and its progeny, and especially its unattached fraction ( fp), is a key parameter in radon dose evaluation. In order to consider the specific features of the atmosphere in the Altamira Cave, the radon and particle concentrations have been measured. The mean annual radon concentration inside the cave over the period 2013?2019 is around 3500 Bq m?3 with a standard deviation of 1833 Bq m?3 and this exhibits seasonal variations. This value surpasses all international (WHO, IAEA, ICRP) upper action and reference levels (occupational and non-occupational). Dose rate levels expressed in ?Sv h?1 were estimated for four different equilibrium scenarios between radon and its progeny 218Po, 214Pb, 214Bi and 214Po. The most recent dose conversion factors have been used and the contribution made to the dose by the unattached fraction of radon progeny fp has been also assessed from the particle concentration. The results suggest that the mean annual dose levels show variations of up to 500% due to the range of F and the fp considered in this study. Given the high radon concentrations usually found in show caves, the best way to reduce this variability and its associated uncertainty in dose assessment is to conduct specific studies aimed at determining both F and fp.
publishDate 2020
dc.date.none.fl_str_mv 2020
2020-06-01
dc.type.none.fl_str_mv journal article
http://purl.org/coar/resource_type/c_6501
NA
http://purl.org/coar/version/c_be7fb7dd8ff6fe43
dc.type.openaire.fl_str_mv info:eu-repo/semantics/article
format article
dc.identifier.none.fl_str_mv http://hdl.handle.net/10902/18373
url http://hdl.handle.net/10902/18373
dc.language.none.fl_str_mv Inglés
eng
language_invalid_str_mv Inglés
language eng
dc.rights.none.fl_str_mv open access
http://purl.org/coar/access_right/c_abf2
dc.rights.openaire.fl_str_mv info:eu-repo/semantics/openAccess
rights_invalid_str_mv open access
http://purl.org/coar/access_right/c_abf2
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv IOP Publishing
publisher.none.fl_str_mv IOP Publishing
dc.source.none.fl_str_mv J. Radiol. Prot. 40 (2020) 367-380
reponame:UCrea Repositorio Abierto de la Universidad de Cantabria
instname:Universidad de Cantabria (UC)
instname_str Universidad de Cantabria (UC)
reponame_str UCrea Repositorio Abierto de la Universidad de Cantabria
collection UCrea Repositorio Abierto de la Universidad de Cantabria
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869405287471906816
score 15,301603