Muscular pattern based on multichannel surface EMG during voluntary contractions of the upper-limb

Tesi per compendi de publicacions.

Detalles Bibliográficos
Autor: Jordanic, Mislav|||0000-0001-6831-3327
Tipo de recurso: tesis doctoral
Fecha de publicación:2017
País:España
Institución:Universitat Politècnica de Catalunya (UPC)
Repositorio:UPCommons. Portal del coneixement obert de la UPC
Idioma:inglés
OAI Identifier:oai:upcommons.upc.edu:2117/114446
Acceso en línea:https://hdl.handle.net/2117/114446
https://dx.doi.org/10.5821/dissertation-2117-114446
Access Level:acceso abierto
Palabra clave:Enginyeria biomèdica
Xarxes neuronals (Neurobiologia)
Robòtica
Àrees temàtiques de la UPC::Enginyeria biomèdica
id ES_2abe8a3e0be67c55832647d7bfcfc854
oai_identifier_str oai:upcommons.upc.edu:2117/114446
network_acronym_str ES
network_name_str España
repository_id_str
dc.title.none.fl_str_mv Muscular pattern based on multichannel surface EMG during voluntary contractions of the upper-limb
title Muscular pattern based on multichannel surface EMG during voluntary contractions of the upper-limb
spellingShingle Muscular pattern based on multichannel surface EMG during voluntary contractions of the upper-limb
Jordanic, Mislav|||0000-0001-6831-3327
Enginyeria biomèdica
Xarxes neuronals (Neurobiologia)
Robòtica
Àrees temàtiques de la UPC::Enginyeria biomèdica
title_short Muscular pattern based on multichannel surface EMG during voluntary contractions of the upper-limb
title_full Muscular pattern based on multichannel surface EMG during voluntary contractions of the upper-limb
title_fullStr Muscular pattern based on multichannel surface EMG during voluntary contractions of the upper-limb
title_full_unstemmed Muscular pattern based on multichannel surface EMG during voluntary contractions of the upper-limb
title_sort Muscular pattern based on multichannel surface EMG during voluntary contractions of the upper-limb
dc.creator.none.fl_str_mv Jordanic, Mislav|||0000-0001-6831-3327
author Jordanic, Mislav|||0000-0001-6831-3327
author_facet Jordanic, Mislav|||0000-0001-6831-3327
author_role author
dc.contributor.none.fl_str_mv Mañanas Villanueva, Miguel Ángel
Rojas Martínez, Mónica
dc.subject.none.fl_str_mv Enginyeria biomèdica
Xarxes neuronals (Neurobiologia)
Robòtica
Àrees temàtiques de la UPC::Enginyeria biomèdica
topic Enginyeria biomèdica
Xarxes neuronals (Neurobiologia)
Robòtica
Àrees temàtiques de la UPC::Enginyeria biomèdica
description Tesi per compendi de publicacions.
publishDate 2017
dc.date.none.fl_str_mv 2017
2017-12-05
2018
2018-02-21
dc.type.none.fl_str_mv doctoral thesis
http://purl.org/coar/resource_type/c_db06
VoR
http://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.openaire.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
dc.identifier.none.fl_str_mv https://hdl.handle.net/2117/114446
https://dx.doi.org/10.5821/dissertation-2117-114446
url https://hdl.handle.net/2117/114446
https://dx.doi.org/10.5821/dissertation-2117-114446
dc.language.none.fl_str_mv Inglés
eng
language_invalid_str_mv Inglés
language eng
dc.rights.none.fl_str_mv open access
http://purl.org/coar/access_right/c_abf2

http://creativecommons.org/licenses/by-nc-nd/4.0/
dc.rights.openaire.fl_str_mv info:eu-repo/semantics/openAccess
rights_invalid_str_mv open access
http://purl.org/coar/access_right/c_abf2

http://creativecommons.org/licenses/by-nc-nd/4.0/
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universitat Politècnica de Catalunya
publisher.none.fl_str_mv Universitat Politècnica de Catalunya
dc.source.none.fl_str_mv reponame:UPCommons. Portal del coneixement obert de la UPC
instname:Universitat Politècnica de Catalunya (UPC)
instname_str Universitat Politècnica de Catalunya (UPC)
reponame_str UPCommons. Portal del coneixement obert de la UPC
collection UPCommons. Portal del coneixement obert de la UPC
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869405091598958592
spelling Muscular pattern based on multichannel surface EMG during voluntary contractions of the upper-limbJordanic, Mislav|||0000-0001-6831-3327Enginyeria biomèdicaXarxes neuronals (Neurobiologia)RobòticaÀrees temàtiques de la UPC::Enginyeria biomèdicaTesi per compendi de publicacions.Extraction of neuromuscular information is an important and extensively researched issue in biomedical engineering. lnformation on muscle control can be used in numerous human-machine interfaces and control applications, including rehabilitation engineering, e.g., prosthetics, exoskeletons and rehabilitation robots. Neuromuscular information can be extracted at the brain level, peripheral nerves, or muscles. Among these options, muscle interface is the only viable way of information extraction in everyday life. Although brain and nerve recordings are promising,they usually require invasive measurement and achieve relatively low extraction speed which prevents real time control. But neuromuscular information can also be inferred from recorded electrical activity generated by contracting muscle(electromyography, EMG). Even though in EMG recordings information is not obtained directly from neural cells, it contains similar information as nerve recording. Given the fact that motoneuron induces action potentials of muscle fibers, information extracted from EMG is equivalent to information extracted from corresponding motor neurons . Moreover, muscles contain multiple motor units that activate simultaneously so their electrical activity sums on the surface oft he skin, resulting in a relatively high amplitude compared to the other bioelectrical signals. Therefore, due to the richness of neural information,non invasiveness and high signal-to-noise ratio, the surface EMG is extensively used for man-machine interfacing, especially in commercial/clinical upper-limb prosthetic control.Motivation and merit of this thesis lies in the fact that information associated with muscular pattern during exercises can be very useful in differenta pplications such as monitoring patients' control strategies during recovery, personalizing rehabilitation processes to increase their effectiveness or to provide information to be used for control of external devices(EMG based control of prosthesis orexoskeletons).Within this Doctoral thesis a pattern recognition approach was used to assess neuromuscular information and to identify subjects' intended motion based on multichannel surface electromyographic recordings. Research was focused on control strategies of upper-limb, both in normal subjects and in patients with impaired mobility caused by incomplete spinal cord injury. Methods which are proposed can be used for the design and monitoring of rehabilitation therapies intended for patients with neuromuscular impairment, as well for the control of external devices like rehabilitation robots, exoskeletons, prostheses and even virtual games.La extracción de información neuromuscular es una problemática importante y extensivamente investigada en el campo dela ingeniería biomédica. La información sobre el control muscular puede ser utilizada en numerosas interfaces hombre máquina y en aplicaciones de control, en las cuales se incluye la ingeniería de rehabilitación, que abarca la utilización de prótesis, exoesqueletos y robots para la rehabilitación. La información neuromuscular puede ser extraída a nivel de cerebro, nervios periféricos, o músculos. Entre estas opciones, la interfaz muscular es la única forma viable de extraer información durante la vida diaria. A pesar de que los registros de señales cerebrales y nerviosas son prometedores, normalmente se necesitan medidas invasivas y su tiempo de extracción es relativamente bajo, previniendo el control en tiempo real. Sin embargo, la información neuromuscular puede ser inferida registrando la actividad eléctrica generada por la contracción del músculo (electromiografía, EMG). A pesar de que en los registros la información no se obtiene directamente por las células neurales, ésta contiene información similar a la obtenida registrando los nervios . Dado el hecho que las motoneuronas inducen potenciales de acción de las fibras musculares, la información extraída por el EMG es equivalente a la información extraída por las correspondientes neuronas motoras. Por otra parte, los músculos contienen unidades motoras múltiples que se activan simultáneamente, de modo que su actividad eléctrica se suma en la superficie de la piel, lo que da como resultado una señal con una amplitud relativamente más elevada comparada a otras señales bioeléctricas. Por lo tanto, debido a la riqueza de información neural, la no invasividad y la elevada relación señal ruido, el EMG superficial se utiliza ampliamente en interfaces hombre-máquina, especialmente en sectores clínicos y comerciales en el control prostético de la extremidad superior. La motivación y el mérito de esta tesis reside en el hecho de que la información asociada con los patrones musculares durante diferentes ejercicios puede ser muy útil en diversas aplicaciones tales como la monitorización de las estrategias de control de pacientes durante las terapias de recuperación, la personalización de los procesos de rehabilitación para aumentar su efectividad o para proveer información que pueda ser utilizada para el control de dispositios externos (Control de prótesis o exoesqueletos basado en EMG).Dentro de esta tesis doctoral se utilizó un enfoque de reconocimiento de patrones para evaluar la información neuromuscular y para identificar la intención de movimiento de los sujetos basado en registros multicanal de EMG superficial. La investigación se centró en las estrategias de control de la extremidad superior, tanto en sujetos sanos como en pacientes con movilidad reducida causada por una lesión incompleta de la médula espinal. Los métodos propuestos pueden ser utilizados para el diseño y monitorización de terapias de rehabilitación para pacientes con deterioro neuromuscular, así como para el control de dispositivos externos tales como robots para la rehabilitación, exoesqueletos, prótesis e incluso videojuegosUniversitat Politècnica de CatalunyaMañanas Villanueva, Miguel ÁngelRojas Martínez, Mónica20172017-12-0520182018-02-21doctoral thesishttp://purl.org/coar/resource_type/c_db06VoRhttp://purl.org/coar/version/c_970fb48d4fbd8a85info:eu-repo/semantics/doctoralThesisapplication/pdfhttps://hdl.handle.net/2117/114446https://dx.doi.org/10.5821/dissertation-2117-114446reponame:UPCommons. Portal del coneixement obert de la UPCinstname:Universitat Politècnica de Catalunya (UPC)Inglésengopen accesshttp://purl.org/coar/access_right/c_abf2http://creativecommons.org/licenses/by-nc-nd/4.0/info:eu-repo/semantics/openAccessoai:upcommons.upc.edu:2117/1144462026-05-27T15:37:01Z
score 15,301603