Comparative Study of the Performance of Two Different Luciferases for the Analysis of Fumonisin B1 in Wheat Samples
The development of two different immunoassays for the determination of fumonisin B1 in wheat samples is reported. A previously described mimopeptide for fumonisin B1 (FB1) was used to produce fusion proteins in combination with two different luciferases: Gaussia luciferase (GLuc) and NanoLuc lucifer...
| Autores: | , , , , , , , , |
|---|---|
| Tipo de recurso: | artículo |
| Fecha de publicación: | 2022 |
| País: | España |
| Institución: | Universidad Complutense de Madrid (UCM) |
| Repositorio: | Docta Complutense |
| Idioma: | inglés |
| OAI Identifier: | oai:docta.ucm.es:20.500.14352/71361 |
| Acceso en línea: | https://hdl.handle.net/20.500.14352/71361 |
| Access Level: | acceso abierto |
| Palabra clave: | 543 bioluminescence fumonisin B1 fusion proteins immunoassays luciferases Química analítica (Química) 2301 Química Analítica |
| id |
ES_2a7fa2aca097155c92cbdb5bec05ee5d |
|---|---|
| oai_identifier_str |
oai:docta.ucm.es:20.500.14352/71361 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Comparative Study of the Performance of Two Different Luciferases for the Analysis of Fumonisin B1 in Wheat SamplesLuque Uria, ÁlvaroPeltomaa, Riikka JohannaNavarro Duro, MarinaFikacek, SabrinaHead, TrajenDeo, Sapna K.Daunert, SylviaBenito Peña, María ElenaMoreno Bondi, María Cruz543bioluminescencefumonisin B1fusion proteinsimmunoassaysluciferasesQuímica analítica (Química)2301 Química AnalíticaThe development of two different immunoassays for the determination of fumonisin B1 in wheat samples is reported. A previously described mimopeptide for fumonisin B1 (FB1) was used to produce fusion proteins in combination with two different luciferases: Gaussia luciferase (GLuc) and NanoLuc luciferase (NLuc). The production, expression and the development of two immunoassays based on these fusion proteins (A2- GLuc and A2-NLuc) is detailed. The assay showing the best performance, A2-NLuc, with a limit of detection of 0.61 ngmL 1 and a dynamic range from 1.9 to 95 ngmL 1 , was employed for the analysis of spiked wheat samples, a reference matrix material, as well as naturally contaminated wheat samples. The recoveries obtained in the spiked samples were acceptable, between 81.5 and 109%, with relative standard deviations lower than 14%. The analysis of naturally contaminated wheat was validated by a liquid chromatography coupled to tandem mass detection method.Wiley-VCHUniversidad Complutense de Madrid20222022-02-1720222022-02-17journal articlehttp://purl.org/coar/resource_type/c_6501info:eu-repo/semantics/articleapplication/pdfhttps://hdl.handle.net/20.500.14352/71361reponame:Docta Complutenseinstname:Universidad Complutense de Madrid (UCM)Inglésengopen accesshttp://purl.org/coar/access_right/c_abf2Atribución-NoComercial-SinDerivadas 3.0 Españahttps://creativecommons.org/licenses/by-nc-nd/3.0/es/info:eu-repo/semantics/openAccessoai:docta.ucm.es:20.500.14352/713612026-06-02T12:44:21Z |
| dc.title.none.fl_str_mv |
Comparative Study of the Performance of Two Different Luciferases for the Analysis of Fumonisin B1 in Wheat Samples |
| title |
Comparative Study of the Performance of Two Different Luciferases for the Analysis of Fumonisin B1 in Wheat Samples |
| spellingShingle |
Comparative Study of the Performance of Two Different Luciferases for the Analysis of Fumonisin B1 in Wheat Samples Luque Uria, Álvaro 543 bioluminescence fumonisin B1 fusion proteins immunoassays luciferases Química analítica (Química) 2301 Química Analítica |
| title_short |
Comparative Study of the Performance of Two Different Luciferases for the Analysis of Fumonisin B1 in Wheat Samples |
| title_full |
Comparative Study of the Performance of Two Different Luciferases for the Analysis of Fumonisin B1 in Wheat Samples |
| title_fullStr |
Comparative Study of the Performance of Two Different Luciferases for the Analysis of Fumonisin B1 in Wheat Samples |
| title_full_unstemmed |
Comparative Study of the Performance of Two Different Luciferases for the Analysis of Fumonisin B1 in Wheat Samples |
| title_sort |
Comparative Study of the Performance of Two Different Luciferases for the Analysis of Fumonisin B1 in Wheat Samples |
| dc.creator.none.fl_str_mv |
Luque Uria, Álvaro Peltomaa, Riikka Johanna Navarro Duro, Marina Fikacek, Sabrina Head, Trajen Deo, Sapna K. Daunert, Sylvia Benito Peña, María Elena Moreno Bondi, María Cruz |
| author |
Luque Uria, Álvaro |
| author_facet |
Luque Uria, Álvaro Peltomaa, Riikka Johanna Navarro Duro, Marina Fikacek, Sabrina Head, Trajen Deo, Sapna K. Daunert, Sylvia Benito Peña, María Elena Moreno Bondi, María Cruz |
| author_role |
author |
| author2 |
Peltomaa, Riikka Johanna Navarro Duro, Marina Fikacek, Sabrina Head, Trajen Deo, Sapna K. Daunert, Sylvia Benito Peña, María Elena Moreno Bondi, María Cruz |
| author2_role |
author author author author author author author author |
| dc.contributor.none.fl_str_mv |
Universidad Complutense de Madrid |
| dc.subject.none.fl_str_mv |
543 bioluminescence fumonisin B1 fusion proteins immunoassays luciferases Química analítica (Química) 2301 Química Analítica |
| topic |
543 bioluminescence fumonisin B1 fusion proteins immunoassays luciferases Química analítica (Química) 2301 Química Analítica |
| description |
The development of two different immunoassays for the determination of fumonisin B1 in wheat samples is reported. A previously described mimopeptide for fumonisin B1 (FB1) was used to produce fusion proteins in combination with two different luciferases: Gaussia luciferase (GLuc) and NanoLuc luciferase (NLuc). The production, expression and the development of two immunoassays based on these fusion proteins (A2- GLuc and A2-NLuc) is detailed. The assay showing the best performance, A2-NLuc, with a limit of detection of 0.61 ngmL 1 and a dynamic range from 1.9 to 95 ngmL 1 , was employed for the analysis of spiked wheat samples, a reference matrix material, as well as naturally contaminated wheat samples. The recoveries obtained in the spiked samples were acceptable, between 81.5 and 109%, with relative standard deviations lower than 14%. The analysis of naturally contaminated wheat was validated by a liquid chromatography coupled to tandem mass detection method. |
| publishDate |
2022 |
| dc.date.none.fl_str_mv |
2022 2022-02-17 2022 2022-02-17 |
| dc.type.none.fl_str_mv |
journal article http://purl.org/coar/resource_type/c_6501 |
| dc.type.openaire.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| dc.identifier.none.fl_str_mv |
https://hdl.handle.net/20.500.14352/71361 |
| url |
https://hdl.handle.net/20.500.14352/71361 |
| dc.language.none.fl_str_mv |
Inglés eng |
| language_invalid_str_mv |
Inglés |
| language |
eng |
| dc.rights.none.fl_str_mv |
open access http://purl.org/coar/access_right/c_abf2 Atribución-NoComercial-SinDerivadas 3.0 España https://creativecommons.org/licenses/by-nc-nd/3.0/es/ |
| dc.rights.openaire.fl_str_mv |
info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
open access http://purl.org/coar/access_right/c_abf2 Atribución-NoComercial-SinDerivadas 3.0 España https://creativecommons.org/licenses/by-nc-nd/3.0/es/ |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
Wiley-VCH |
| publisher.none.fl_str_mv |
Wiley-VCH |
| dc.source.none.fl_str_mv |
reponame:Docta Complutense instname:Universidad Complutense de Madrid (UCM) |
| instname_str |
Universidad Complutense de Madrid (UCM) |
| reponame_str |
Docta Complutense |
| collection |
Docta Complutense |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869405072254828544 |
| score |
15.301603 |