Disturbing Effect of Intra-Tissue Temperature Sensors in Pre-Clinical Experimental Studies of Radiofrequency Cardiac Ablation: A Computer-Based Modeling Study
[EN] Background: Preclinical studies on radiofrequency (RF) cardiac ablation (RFCA) use very small temperature sensors in specific positions in the tissue subjected to RF heating. Despite the sensors' small size, the proximity to the ablation electrode and the extremely high thermal gradien...
| Autores: | , , , |
|---|---|
| Tipo de recurso: | artículo |
| Fecha de publicación: | 2023 |
| País: | España |
| Institución: | Universitat Politècnica de València (UPV) |
| Repositorio: | RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia |
| Idioma: | inglés |
| OAI Identifier: | oai:riunet.upv.es:10251/193321 |
| Acceso en línea: | https://riunet.upv.es/handle/10251/193321 |
| Access Level: | acceso abierto |
| Palabra clave: | Cardiac ablation Computer modeling Pre-clinical model Radiofrequency ablation Temperature sensors TECNOLOGIA ELECTRONICA |
| id |
ES_27da37f5d936fcddf1007293deaed7e4 |
|---|---|
| oai_identifier_str |
oai:riunet.upv.es:10251/193321 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Disturbing Effect of Intra-Tissue Temperature Sensors in Pre-Clinical Experimental Studies of Radiofrequency Cardiac Ablation: A Computer-Based Modeling StudyLuisBerjano, Enrique|||0000-0002-3247-2665González-Suárez, Ana|||0000-0002-1813-4176Pérez, Juan J|||0000-0001-8486-8699Cardiac ablationComputer modelingPre-clinical modelRadiofrequency ablationTemperature sensorsTECNOLOGIA ELECTRONICA[EN] Background: Preclinical studies on radiofrequency (RF) cardiac ablation (RFCA) use very small temperature sensors in specific positions in the tissue subjected to RF heating. Despite the sensors' small size, the proximity to the ablation electrode and the extremely high thermal gradient around the electrode means that the presence of the temperature sensors could distort the temperatures recorded. Our objective was to assess the thermal impact of intra-tissue temperature sensors during RFCA. Methods: 3D RFCA models were built including different temperature sensors based on fiber optics and T-type thermocouples. Constant power ablation was simulated for 10 s. Results: The results showed that the disturbance caused by the presence of the T-type thermocouples was considerably greater (one order of magnitude) than that caused by the optical fibers. The closer the sensor was to the ablation electrode, the greater the greater the disturbance was and the more it increased with time in sensors more than 3 mm deep. The fiber optic measurements always slightly underestimated (<0.2 'C) the tissue temperature that would exist without the sensors, while the disturbance caused by the T-type thermocouples did not always result in underestimation but depended on the depth of the sensors parallel to the catheter. Conclusions: The presence of thermocouples inserted into the tissue close to the RF ablation electrode involves a disturbance that could affect the measured temperature value, although it does not substantially alter the shape and size of the thermal lesion. Optical fibers cause much less disturbance, possibly due to the absence of internal metal parts that favor heat conduction.This research was funded by the Spanish Ministerio de Ciencia e Innovación/Agencia Estatal de Investigación (MCIN/AEI/10.13039/501100011033) by Grant number PID2022-136273OBC31 and PID2022-136273OA-C33.MDPI AGDepartamento de Ingeniería ElectrónicaEscuela Técnica Superior de Ingeniería Aeroespacial y Diseño IndustrialEscuela Técnica Superior de Ingeniería IndustrialEscuela Politécnica Superior de GandiaBiosignals & Minimally Invasive Technologies-BioMITAgencia Estatal de InvestigaciónRepositorio Institucional de la Universitat Politècnica de València Riunet20232023-04-11journal articlehttp://purl.org/coar/resource_type/c_6501VoRhttp://purl.org/coar/version/c_970fb48d4fbd8a85info:eu-repo/semantics/articleapplication/pdfhttps://riunet.upv.es/handle/10251/193321reponame:RiuNet. Repositorio Institucional de la Universitat Politécnica de Valénciainstname:Universitat Politècnica de València (UPV)InglésengAgencia Estatal de Investigación http://dx.doi.org/10.13039/501100011033 PID2022-136273OBC31Agencia Estatal de Investigación http://dx.doi.org/10.13039/501100011033 PID2022-136273OA-C33open accesshttp://purl.org/coar/access_right/c_abf2Reconocimiento (by)http://creativecommons.org/licenses/by/4.0/info:eu-repo/semantics/openAccessoai:riunet.upv.es:10251/1933212026-06-13T07:49:27Z |
| dc.title.none.fl_str_mv |
Disturbing Effect of Intra-Tissue Temperature Sensors in Pre-Clinical Experimental Studies of Radiofrequency Cardiac Ablation: A Computer-Based Modeling Study |
| title |
Disturbing Effect of Intra-Tissue Temperature Sensors in Pre-Clinical Experimental Studies of Radiofrequency Cardiac Ablation: A Computer-Based Modeling Study |
| spellingShingle |
Disturbing Effect of Intra-Tissue Temperature Sensors in Pre-Clinical Experimental Studies of Radiofrequency Cardiac Ablation: A Computer-Based Modeling Study Luis Cardiac ablation Computer modeling Pre-clinical model Radiofrequency ablation Temperature sensors TECNOLOGIA ELECTRONICA |
| title_short |
Disturbing Effect of Intra-Tissue Temperature Sensors in Pre-Clinical Experimental Studies of Radiofrequency Cardiac Ablation: A Computer-Based Modeling Study |
| title_full |
Disturbing Effect of Intra-Tissue Temperature Sensors in Pre-Clinical Experimental Studies of Radiofrequency Cardiac Ablation: A Computer-Based Modeling Study |
| title_fullStr |
Disturbing Effect of Intra-Tissue Temperature Sensors in Pre-Clinical Experimental Studies of Radiofrequency Cardiac Ablation: A Computer-Based Modeling Study |
| title_full_unstemmed |
Disturbing Effect of Intra-Tissue Temperature Sensors in Pre-Clinical Experimental Studies of Radiofrequency Cardiac Ablation: A Computer-Based Modeling Study |
| title_sort |
Disturbing Effect of Intra-Tissue Temperature Sensors in Pre-Clinical Experimental Studies of Radiofrequency Cardiac Ablation: A Computer-Based Modeling Study |
| dc.creator.none.fl_str_mv |
Luis Berjano, Enrique|||0000-0002-3247-2665 González-Suárez, Ana|||0000-0002-1813-4176 Pérez, Juan J|||0000-0001-8486-8699 |
| author |
Luis |
| author_facet |
Luis Berjano, Enrique|||0000-0002-3247-2665 González-Suárez, Ana|||0000-0002-1813-4176 Pérez, Juan J|||0000-0001-8486-8699 |
| author_role |
author |
| author2 |
Berjano, Enrique|||0000-0002-3247-2665 González-Suárez, Ana|||0000-0002-1813-4176 Pérez, Juan J|||0000-0001-8486-8699 |
| author2_role |
author author author |
| dc.contributor.none.fl_str_mv |
Departamento de Ingeniería Electrónica Escuela Técnica Superior de Ingeniería Aeroespacial y Diseño Industrial Escuela Técnica Superior de Ingeniería Industrial Escuela Politécnica Superior de Gandia Biosignals & Minimally Invasive Technologies-BioMIT Agencia Estatal de Investigación Repositorio Institucional de la Universitat Politècnica de València Riunet |
| dc.subject.none.fl_str_mv |
Cardiac ablation Computer modeling Pre-clinical model Radiofrequency ablation Temperature sensors TECNOLOGIA ELECTRONICA |
| topic |
Cardiac ablation Computer modeling Pre-clinical model Radiofrequency ablation Temperature sensors TECNOLOGIA ELECTRONICA |
| description |
[EN] Background: Preclinical studies on radiofrequency (RF) cardiac ablation (RFCA) use very small temperature sensors in specific positions in the tissue subjected to RF heating. Despite the sensors' small size, the proximity to the ablation electrode and the extremely high thermal gradient around the electrode means that the presence of the temperature sensors could distort the temperatures recorded. Our objective was to assess the thermal impact of intra-tissue temperature sensors during RFCA. Methods: 3D RFCA models were built including different temperature sensors based on fiber optics and T-type thermocouples. Constant power ablation was simulated for 10 s. Results: The results showed that the disturbance caused by the presence of the T-type thermocouples was considerably greater (one order of magnitude) than that caused by the optical fibers. The closer the sensor was to the ablation electrode, the greater the greater the disturbance was and the more it increased with time in sensors more than 3 mm deep. The fiber optic measurements always slightly underestimated (<0.2 'C) the tissue temperature that would exist without the sensors, while the disturbance caused by the T-type thermocouples did not always result in underestimation but depended on the depth of the sensors parallel to the catheter. Conclusions: The presence of thermocouples inserted into the tissue close to the RF ablation electrode involves a disturbance that could affect the measured temperature value, although it does not substantially alter the shape and size of the thermal lesion. Optical fibers cause much less disturbance, possibly due to the absence of internal metal parts that favor heat conduction. |
| publishDate |
2023 |
| dc.date.none.fl_str_mv |
2023 2023-04-11 |
| dc.type.none.fl_str_mv |
journal article http://purl.org/coar/resource_type/c_6501 VoR http://purl.org/coar/version/c_970fb48d4fbd8a85 |
| dc.type.openaire.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| dc.identifier.none.fl_str_mv |
https://riunet.upv.es/handle/10251/193321 |
| url |
https://riunet.upv.es/handle/10251/193321 |
| dc.language.none.fl_str_mv |
Inglés eng |
| language_invalid_str_mv |
Inglés |
| language |
eng |
| dc.relation.none.fl_str_mv |
Agencia Estatal de Investigación http://dx.doi.org/10.13039/501100011033 PID2022-136273OBC31 Agencia Estatal de Investigación http://dx.doi.org/10.13039/501100011033 PID2022-136273OA-C33 |
| dc.rights.none.fl_str_mv |
open access http://purl.org/coar/access_right/c_abf2 Reconocimiento (by) http://creativecommons.org/licenses/by/4.0/ |
| dc.rights.openaire.fl_str_mv |
info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
open access http://purl.org/coar/access_right/c_abf2 Reconocimiento (by) http://creativecommons.org/licenses/by/4.0/ |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
MDPI AG |
| publisher.none.fl_str_mv |
MDPI AG |
| dc.source.none.fl_str_mv |
reponame:RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia instname:Universitat Politècnica de València (UPV) |
| instname_str |
Universitat Politècnica de València (UPV) |
| reponame_str |
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia |
| collection |
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869404911649685504 |
| score |
15,300719 |