The reproducibility of late gadolinium enhancement cardiovascular magnetic resonance imaging of post-ablation atrial scar: a cross-over study

Background: Cardiovascular magnetic resonance (CMR) imaging has been used to visualise post-ablation atrial scar (PAAS), generally employing a three-dimensional (3D) late gadolinium enhancement (LGE) technique. However the reproducibility of PAAS imaging has not been determined. This cross-over stud...

ver descrição completa

Detalhes bibliográficos
Autores: Chubb, Henry, Karim, Rashed, Roujol, Sébastien, Nuñez-Garcia, Marta, Williams, Steven E., Whitaker, John, Harrison, James, Butakoff, Constantine, Camara, Oscar, Chiribiri, Amedeo, Schaeffter, Tobias, Wright, Matthew, O'Neill, Mark, Razavi, Reza
Formato: artículo
Estado:Versión publicada
Fecha de publicación:2018
País:España
Recursos:Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)
Repositorio:Recercat. Dipósit de la Recerca de Catalunya
OAI Identifier:oai:recercat.cat:10230/47839
Acesso em linha:http://hdl.handle.net/10230/47839
http://dx.doi.org/10.1186/s12968-018-0438-y
Access Level:acceso abierto
Palavra-chave:Atrial fibrillation
Cardiac magnetic resonance imaging
Catheter ablation
Atrium
Optimization
Late gadolinium enhancement
id ES_20e9f360ce57e51e689d067d4dfffe1e
oai_identifier_str oai:recercat.cat:10230/47839
network_acronym_str ES
network_name_str España
repository_id_str
dc.title.none.fl_str_mv The reproducibility of late gadolinium enhancement cardiovascular magnetic resonance imaging of post-ablation atrial scar: a cross-over study
title The reproducibility of late gadolinium enhancement cardiovascular magnetic resonance imaging of post-ablation atrial scar: a cross-over study
spellingShingle The reproducibility of late gadolinium enhancement cardiovascular magnetic resonance imaging of post-ablation atrial scar: a cross-over study
Chubb, Henry
Atrial fibrillation
Cardiac magnetic resonance imaging
Catheter ablation
Atrium
Optimization
Late gadolinium enhancement
title_short The reproducibility of late gadolinium enhancement cardiovascular magnetic resonance imaging of post-ablation atrial scar: a cross-over study
title_full The reproducibility of late gadolinium enhancement cardiovascular magnetic resonance imaging of post-ablation atrial scar: a cross-over study
title_fullStr The reproducibility of late gadolinium enhancement cardiovascular magnetic resonance imaging of post-ablation atrial scar: a cross-over study
title_full_unstemmed The reproducibility of late gadolinium enhancement cardiovascular magnetic resonance imaging of post-ablation atrial scar: a cross-over study
title_sort The reproducibility of late gadolinium enhancement cardiovascular magnetic resonance imaging of post-ablation atrial scar: a cross-over study
dc.creator.none.fl_str_mv Chubb, Henry
Karim, Rashed
Roujol, Sébastien
Nuñez-Garcia, Marta
Williams, Steven E.
Whitaker, John
Harrison, James
Butakoff, Constantine
Camara, Oscar
Chiribiri, Amedeo
Schaeffter, Tobias
Wright, Matthew
O'Neill, Mark
Razavi, Reza
author Chubb, Henry
author_facet Chubb, Henry
Karim, Rashed
Roujol, Sébastien
Nuñez-Garcia, Marta
Williams, Steven E.
Whitaker, John
Harrison, James
Butakoff, Constantine
Camara, Oscar
Chiribiri, Amedeo
Schaeffter, Tobias
Wright, Matthew
O'Neill, Mark
Razavi, Reza
author_role author
author2 Karim, Rashed
Roujol, Sébastien
Nuñez-Garcia, Marta
Williams, Steven E.
Whitaker, John
Harrison, James
Butakoff, Constantine
Camara, Oscar
Chiribiri, Amedeo
Schaeffter, Tobias
Wright, Matthew
O'Neill, Mark
Razavi, Reza
author2_role author
author
author
author
author
author
author
author
author
author
author
author
author
dc.subject.none.fl_str_mv Atrial fibrillation
Cardiac magnetic resonance imaging
Catheter ablation
Atrium
Optimization
Late gadolinium enhancement
topic Atrial fibrillation
Cardiac magnetic resonance imaging
Catheter ablation
Atrium
Optimization
Late gadolinium enhancement
description Background: Cardiovascular magnetic resonance (CMR) imaging has been used to visualise post-ablation atrial scar (PAAS), generally employing a three-dimensional (3D) late gadolinium enhancement (LGE) technique. However the reproducibility of PAAS imaging has not been determined. This cross-over study is the first to investigate the reproducibility of the technique, crucial for both future research design and clinical implementation. Methods: Forty subjects undergoing first time ablation for atrial fibrillation (AF) had detailed CMR assessment of PAAS. Following baseline pre-ablation scan, two scans (separated by 48 h) were performed at three months post-ablation. Each scan session included 3D LGE acquisition at 10, 20 and 30 min post administration of gadolinium-based contrast agent (GBCA). Subjects were allocated at second scan post-ablation to identical imaging parameters (‘Repro’, n = 10), 3 T scanner (‘3 T’, n = 10), half-slice thickness (‘Half-slice’, n = 10) or half GBCA dose (‘Half-gad’, n = 10). PAAS was compared to baseline scar and then reproducibility was assessed for two measures of thresholded scar (% left atrial (LA) occupied by PAAS (%LA PAAS) and Pulmonary Vein Encirclement (PVE)), and then four measures of non-thresholded scar (point-by-point assessment of PAAS, four normalisation methods). Thresholded measures of PAAS were evaluated against procedural outcome (AF recurrence). Results: A total of 271 3D acquisitions (out of maximum 280, 96.7%) were acquired. At 20 and 30 min, inter-scan reproducibility was good to excellent (coefficient of variation at 20 min and 30 min: %LA PAAS 0.41 and 0.20; PVE 0.13 and 0.04 respectively for ‘Repro’ group). Changes in imaging parameters, especially reduced GBCA dose, reduced inter-scan reproducibility, but for most measures remained good to excellent (ICC for %LA PAAS 0.454–0.825, PVE 0.618–0.809 at 30 min). For non-thresholded scar, highest reproducibility was observed using blood pool z-score normalisation technique: inter-scan ICC 0.759 (absolute agreement, ‘Repro’ group). There was no significant relationship between indices of PAAS and AF recurrence. Conclusion: PAAS imaging is a reproducible finding. Imaging should be performed at least 20 min post-GBCA injection, and a blood pool z-score should be considered for normalisation of signal intensities. The clinical implications of these findings remain to be established in the absence of a simple correlation with arrhythmia outcome.
publishDate 2018
dc.date.none.fl_str_mv 2018
2021
2021
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/10230/47839
http://dx.doi.org/10.1186/s12968-018-0438-y
url http://hdl.handle.net/10230/47839
http://dx.doi.org/10.1186/s12968-018-0438-y
dc.language.none.fl_str_mv Inglés
language_invalid_str_mv Inglés
dc.relation.none.fl_str_mv Journal of Cardiovascular Magnetic Resonance. 2018;20:21
info:eu-repo/grantAgreement/ES/1PE/DPI2015-71640-R
dc.rights.none.fl_str_mv http://creativecommons.org/licenses/by/4.0/
info:eu-repo/semantics/openAccess
rights_invalid_str_mv http://creativecommons.org/licenses/by/4.0/
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv BioMed Central
publisher.none.fl_str_mv BioMed Central
dc.source.none.fl_str_mv reponame:Recercat. Dipósit de la Recerca de Catalunya
instname:Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)
instname_str Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)
reponame_str Recercat. Dipósit de la Recerca de Catalunya
collection Recercat. Dipósit de la Recerca de Catalunya
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869404486203604992
spelling The reproducibility of late gadolinium enhancement cardiovascular magnetic resonance imaging of post-ablation atrial scar: a cross-over studyChubb, HenryKarim, RashedRoujol, SébastienNuñez-Garcia, MartaWilliams, Steven E.Whitaker, JohnHarrison, JamesButakoff, ConstantineCamara, OscarChiribiri, AmedeoSchaeffter, TobiasWright, MatthewO'Neill, MarkRazavi, RezaAtrial fibrillationCardiac magnetic resonance imagingCatheter ablationAtriumOptimizationLate gadolinium enhancementBackground: Cardiovascular magnetic resonance (CMR) imaging has been used to visualise post-ablation atrial scar (PAAS), generally employing a three-dimensional (3D) late gadolinium enhancement (LGE) technique. However the reproducibility of PAAS imaging has not been determined. This cross-over study is the first to investigate the reproducibility of the technique, crucial for both future research design and clinical implementation. Methods: Forty subjects undergoing first time ablation for atrial fibrillation (AF) had detailed CMR assessment of PAAS. Following baseline pre-ablation scan, two scans (separated by 48 h) were performed at three months post-ablation. Each scan session included 3D LGE acquisition at 10, 20 and 30 min post administration of gadolinium-based contrast agent (GBCA). Subjects were allocated at second scan post-ablation to identical imaging parameters (‘Repro’, n = 10), 3 T scanner (‘3 T’, n = 10), half-slice thickness (‘Half-slice’, n = 10) or half GBCA dose (‘Half-gad’, n = 10). PAAS was compared to baseline scar and then reproducibility was assessed for two measures of thresholded scar (% left atrial (LA) occupied by PAAS (%LA PAAS) and Pulmonary Vein Encirclement (PVE)), and then four measures of non-thresholded scar (point-by-point assessment of PAAS, four normalisation methods). Thresholded measures of PAAS were evaluated against procedural outcome (AF recurrence). Results: A total of 271 3D acquisitions (out of maximum 280, 96.7%) were acquired. At 20 and 30 min, inter-scan reproducibility was good to excellent (coefficient of variation at 20 min and 30 min: %LA PAAS 0.41 and 0.20; PVE 0.13 and 0.04 respectively for ‘Repro’ group). Changes in imaging parameters, especially reduced GBCA dose, reduced inter-scan reproducibility, but for most measures remained good to excellent (ICC for %LA PAAS 0.454–0.825, PVE 0.618–0.809 at 30 min). For non-thresholded scar, highest reproducibility was observed using blood pool z-score normalisation technique: inter-scan ICC 0.759 (absolute agreement, ‘Repro’ group). There was no significant relationship between indices of PAAS and AF recurrence. Conclusion: PAAS imaging is a reproducible finding. Imaging should be performed at least 20 min post-GBCA injection, and a blood pool z-score should be considered for normalisation of signal intensities. The clinical implications of these findings remain to be established in the absence of a simple correlation with arrhythmia outcome.The research was performed at King’s College London Medical Engineering Centre, funded by the Wellcome Trust and the Engineering and Physical Sciences Research Council (EPSRC). The research was also supported by the National Institute for Health Research (NIHR) Biomedical Research Centre awards to Guy’s and St Thomas’ NHS Foundation Trust in partnership with King’s College London, by the NIHR Healthcare Technology Co-operative for Cardiovascular Disease at Guy’s and St Thomas’ NHS Foundation Trust, and by the Cardiovascular HTC. Work upon the PVE methodology was partially funded by the Spanish Ministry of Economy and Competitiveness (DPI2015-71640-R) and by the “Fundació La Marató de TV3” (no. 20154031).BioMed Central202120212018info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfapplication/pdfhttp://hdl.handle.net/10230/47839http://dx.doi.org/10.1186/s12968-018-0438-yreponame:Recercat. Dipósit de la Recerca de Catalunyainstname:Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)InglésJournal of Cardiovascular Magnetic Resonance. 2018;20:21info:eu-repo/grantAgreement/ES/1PE/DPI2015-71640-R© The Author(s). 2018 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise statedhttp://creativecommons.org/licenses/by/4.0/info:eu-repo/semantics/openAccessoai:recercat.cat:10230/478392026-05-29T05:05:01Z
score 15,812455