Factors that affect the permeability of commercial hollow-fibre membranes in a submerged anaerobic MBR (HF-SAnMBR) system

A demonstration plant with two commercial HF ultrafiltration membrane modules (PURON (R), Koch Membrane Systems, PUR-PSH31) was operated with urban wastewater. The effect of the main operating variables on membrane performance at sub-critical and supracritical filtration conditions was tested. The p...

ver descrição completa

Detalhes bibliográficos
Autores: Robles Martínez, Ángel, Ruano García, María Victoria, Ribes Bertomeu, Jose, FERRER, J.
Tipo de documento: artigo
Data de publicação:2013
País:España
Recursos:Universitat Politècnica de València (UPV)
Repositório:RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Idioma:inglês
OAI Identifier:oai:riunet.upv.es:10251/46933
Acesso em linha:https://riunet.upv.es/handle/10251/46933
Access Level:Acceso aberto
Palavra-chave:Back-flush frequency
Biogas sparging
Commercial
Hollow-fibre membranes
Submerged anaerobic membrane bioreactor
Membrane permeability
INGENIERIA HIDRAULICA
TECNOLOGIA DEL MEDIO AMBIENTE
Descrição
Resumo:A demonstration plant with two commercial HF ultrafiltration membrane modules (PURON (R), Koch Membrane Systems, PUR-PSH31) was operated with urban wastewater. The effect of the main operating variables on membrane performance at sub-critical and supracritical filtration conditions was tested. The physical operating variables that affected membrane performance most were gas sparging intensity and back-flush (BF) frequency. Indeed, low gas sparging intensities (around 0.23 Nm(3) h(-1) m(-2)) and low BF frequencies (30s back-flush for every 10 basic filtration relaxation cycles) were enough to enable membranes to be operated sub-critically even when levels of mixed liquor total solids were high (up to 25 g L-1). On the other hand, significant gas sparging intensities and BF frequencies were required in order to maintain long-term operating at supra-critical filtration conditions. After operating for more than two years at sub-critical conditions (transmembrane flux between 9 and 13.3 LMH at gas sparging intensities of around 0.23 Nm(3) h(-1) m(-2) and MLTS levels from around 10-30 g L-1) no significant irreversible/irrecoverable fouling problems were detected (membrane permeability remained above 100 LMH bar(-1) and total filtration resistance remained below 10(13) m(-1)), therefore no chemical cleaning was conducted. Membrane performance was similar to the aerobic HF membranes operated in full-scale MBR plants. (C) 2012 Elsevier Ltd. All rights reserved.