Misdiagnosis of Myocardial Infarction Related to Limitations of the Current Regulatory Approach to Define Clinical Decision Values for Cardiac Troponin.

BACKGROUND: Misdiagnosis of acute myocardial infarction (AMI) may significantly harm patients and may result from inappropriate clinical decision values (CDVs) for cardiac troponin (cTn) owing to limitations in the current regulatory process. METHODS AND RESULTS: In an international, prospective, mu...

Descripción completa

Detalles Bibliográficos
Autores: Wildi, Karin, Mueller, Christian, Rubini Gimenez, Maria
Tipo de recurso: artículo
Estado:Versión publicada
Fecha de publicación:2015
País:España
Institución:Universitat Pompeu Fabra
Repositorio:Repositorio Digital de la UPF
OAI Identifier:oai:repositori.upf.edu:10230/24890
Acceso en línea:http://hdl.handle.net/10230/24890
http://dx.doi.org/10.1161/CIRCULATIONAHA.114.014129
Access Level:acceso abierto
Palabra clave:Sistema cardiovascular -- Malalties
Infart de miocardi
Marcadors bioquímics
Descripción
Sumario:BACKGROUND: Misdiagnosis of acute myocardial infarction (AMI) may significantly harm patients and may result from inappropriate clinical decision values (CDVs) for cardiac troponin (cTn) owing to limitations in the current regulatory process. METHODS AND RESULTS: In an international, prospective, multicenter study, we quantified the incidence of inconsistencies in the diagnosis of AMI using fully characterized and clinically available high-sensitivity (hs) cTn assays (hs-cTnI, Abbott; hs-cTnT, Roche) among 2300 consecutive patients with suspected AMI. We hypothesized that the approved CDVs for the 2 assays are not biologically equivalent and might therefore contribute to inconsistencies in the diagnosis of AMI. Findings were validated by use of sex-specific CDVs and parallel measurements of other hs-cTnI assays. AMI was the adjudicated diagnosis in 473 patients (21%). Among these, 86 patients (18.2%) had inconsistent diagnoses when the approved uniform CDV was used. When sex-specific CDVs were used, 14.1% of female and 22.7% of male AMI patients had inconsistent diagnoses. Using biologically equivalent CDV reduced inconsistencies to 10% (P<0.001). These findings were confirmed with parallel measurements of other hs-cTn assays. The incidence of inconsistencies was only 7.0% for assays with CDVs that were nearly biologically equivalent. Patients with inconsistent AMI had long-term mortality comparable to that of patients with consistent diagnoses (P=NS) and a trend toward higher long-term mortality than patients diagnosed with unstable angina (P=0.05). CONCLUSIONS: Currently approved CDVs are not biologically equivalent and contribute to major inconsistencies in the diagnosis of AMI. One of 5 AMI patients will receive a diagnosis other than AMI if managed with the alternative hs-cTn assay.