Relationship between the posterior atrial wall and the esophagus: Esophageal position during atrial fibrillation ablation.

Background Atrial fibrillation ablation implies a risk of esophageal thermal injury. Esophageal position can be analyzed with imaging techniques, but evidence for esophageal mobility is inconsistent. Objectives The purpose of this study was to analyze esophageal position stability from one procedure...

Descripción completa

Detalles Bibliográficos
Autores: Teres, C, Soto-Iglesias, D, Penela, D, Jáuregui, B, Ordoñez, A, Chauca, A, Carreño, JM, Scherer, C, Huguet, M, Ramírez, C, Mandujano, JT, Maldonado, G, Panaro, A, Carballo, J, Cámara, Ó, Ortiz-Pérez, JT, Berruezo, A
Tipo de recurso: artículo
Estado:Versión publicada
Fecha de publicación:2022
País:España
Institución:Universidad de Zaragoza
Repositorio:Zaguán. Repositorio Digital de la Universidad de Zaragoza
OAI Identifier:oai:zaguan.unizar.es:168328
Acceso en línea:http://zaguan.unizar.es/record/168328
Access Level:acceso abierto
Descripción
Sumario:Background Atrial fibrillation ablation implies a risk of esophageal thermal injury. Esophageal position can be analyzed with imaging techniques, but evidence for esophageal mobility is inconsistent. Objectives The purpose of this study was to analyze esophageal position stability from one procedure to another and during a single procedure. Methods Esophageal position was compared in 2 patient groups. First, preprocedural multidetector computerized tomography (MDCT) of first pulmonary vein isolation and redo intervention (redo group) was segmented with ADAS 3D™ to compare the stability of the atrioesophageal isodistance prints. Second, 3 imaging modalities were compared for the same procedure (multimodality group): (1) preprocedural MDCT; (2) intraprocedural fluoroscopy obtained with the transesophageal echocardiographic probe in place with CARTOUNIVU™; and (3) esophageal fast anatomic map (FAM) at the end of the procedure. Esophageal position correlation between different imaging techniques was computed in MATLAB using semiautomatic segmentation analysis. Results Thirty-five redo patients were analyzed and showed a mean atrioesophageal distance of 1.2 ± 0.6 mm and a correlation between first and redo procedure esophageal fingerprint of 91% ± 5%. Only 3 patients (8%) had a clearly different position. The multi-imaging group was composed of 100 patients. Esophageal position correlation between MDCT and CARTOUNIVU was 82% ± 10%; between MDCT and esophageal FAM was 80% ± 12%; and between esophageal FAM and CARTOUNIVU was 83% ± 15%. Conclusion There is high stability of esophageal position between procedures and from the beginning to the end of a procedure. Further research is undergoing to test the clinical utility of the esophageal fingerprinted isodistance map to the posterior atrial wall.