Pulsed-temperature metal oxide gas sensors for microwatt power consumption

Metal Oxide (MOX) gas sensors rely on chemical reactions that occur efficiently at high temperatures, resulting in too-demanding power requirements for certain applications. Operating the sensor under a Pulsed-Temperature Operation (PTO), by which the sensor heater is switched ON and OFF periodicall...

Full description

Bibliographic Details
Authors: Palacio Bonet, Francisco, Fonollosa Magrinyà, Jordi|||0000-0001-8854-8588, Burgués Illa, Xavier|||0000-0001-6974-9886, Gómez Cama, José Mª, Marco Colás, Santiago
Format: article
Publication Date:2020
Country:España
Institution:Universitat Politècnica de Catalunya (UPC)
Repository:UPCommons. Portal del coneixement obert de la UPC
Language:English
OAI Identifier:oai:upcommons.upc.edu:2117/335264
Online Access:https://hdl.handle.net/2117/335264
https://dx.doi.org/10.1109/ACCESS.2020.2987066
Access Level:Open access
Keyword:Chemical detectors
Electronic nose
gas sensors
low-power operation
machine olfaction
pulsed-temperature operation
temperature modulation
robot sensing systems
temperature sensors
heating systems
gas detectors
power demand
sensitivity
Sensors químics
Nas electrònic
Àrees temàtiques de la UPC::Enginyeria electrònica::Instrumentació i mesura::Sensors i actuadors
Description
Summary:Metal Oxide (MOX) gas sensors rely on chemical reactions that occur efficiently at high temperatures, resulting in too-demanding power requirements for certain applications. Operating the sensor under a Pulsed-Temperature Operation (PTO), by which the sensor heater is switched ON and OFF periodically, is a common practice to reduce the power consumption. However, the sensor performance is degraded as the OFF periods become larger. Other research works studied, generally, PTO schemes applying waveforms to the heater with time periods of seconds and duty cycles above 20%. Here, instead, we explore the behaviour of PTO sensors working under aggressive schemes, reaching power savings of 99% and beyond with respect to continuous heater stimulation. Using sensor sensitivity and the limit of detection, we evaluated four Ultra Low Power (ULP) sensors under different PTO schemes exposed to ammonia, ethylene, and acetaldehyde. Results show that it is possible to operate the sensors with total power consumption in the range of microwatts. Despite the aggressive power reduction, sensor sensitivity suffers only a moderate decline and the limit of detection may degrade up to a factor five. This is, however, gas-dependent and should be explored on a case-by-case basis since, for example, the same degradation has not been observed for ammonia. Finally, the run-in time, i.e., the time required to get a stable response immediately after switching on the sensor, increases when reducing the power consumption, from 10 minutes to values in the range of 10-20 hours for power consumptions smaller than 200 microwatts.