Clinical performance evaluation of the Idylla (TM) EGFR Mutation Test on formalin-fixed paraffin-embedded tissue of non-small cell lung cáncer
Background: Detection of epidermal growth factor receptor (EGFR) mutations in exons 18-21 is recommended in all patients with advanced Non-small-cell lung carcinoma due to the demonstrated efficiency of the standard therapy with tyrosine kinase inhibitors in EGFR-mutated patients. Therefore, choosin...
| Autores: | , , , , , , , |
|---|---|
| Tipo de recurso: | artículo |
| Estado: | Versión publicada |
| Fecha de publicación: | 2020 |
| País: | España |
| Institución: | Universidad de Sevilla (US) |
| Repositorio: | idUS. Depósito de Investigación de la Universidad de Sevilla |
| OAI Identifier: | oai:idus.us.es:11441/145480 |
| Acceso en línea: | https://hdl.handle.net/11441/145480 https://doi.org/10.1186/s12885-020-6697-7 |
| Access Level: | acceso abierto |
| Palabra clave: | EGFR Mutations Non-small-cell lung carcinoma |
| Sumario: | Background: Detection of epidermal growth factor receptor (EGFR) mutations in exons 18-21 is recommended in all patients with advanced Non-small-cell lung carcinoma due to the demonstrated efficiency of the standard therapy with tyrosine kinase inhibitors in EGFR-mutated patients. Therefore, choosing a suitable technique to test EGFR mutational status is crucial to warrant a valid result in a short turnaround time using the lowest possible amount of tissue material. The Idylla™ EGFR Mutation Test is a simple, fast and reliable method designed for the detection of EGFR mutations from formalin-fixed paraffin-embedded samples. The aim of this study was the Clinical Performace Evaluation of the Idylla™ EGFR Mutation Test on the Idylla™ System. Methods: EGFR mutational status was determined on 132 archived formalin-fixed paraffin-embedded tissue sections with Idylla™ technology. Results were compared with the results previously obtained by routine method in the reference lab (Therascreen® EGFR RGQ PCR v2, Qiagen in Molecular Pathology lab, Hospital Universitario Virgen del Rocío de Sevilla). Results: The overall agreement between results obtained with the Idylla™ EGFR Mutation Test and the Comparator test method was 95.38% (with 1-sided 95% lower limit of 91.7%) showing Positive Diagnostic Agreement of 93.22% and Negative Diagnostic Agreement of 97.18%, with a Limit Of Detection ≤5%. Conclusions: The Idylla™ EGFR Mutation Test passed its clinical validity performance characteristics for accuracy. |
|---|