Mathematical modeling and numerical simulation of surfactant delivery within a physical model of the neonatal trachea for different aerosol characteristics

Surfactant aerosol delivery in conjunction with a noninvasive respiratory support holds the potential to treat neonatal respiratory distress syndrome in a safe manner. The objective of the present study was to gain knowledge in order to optimize the geometry of an intracorporeal inhalation catheter...

Descripción completa

Detalles Bibliográficos
Autores: Goikoetxea-Miranda, E. (Estibalitz)|||/items/830d536f-178a-4369-ab78-95e2565327fa, Rivas-Nieto, A. (Alejandro)|||/items/54d35156-a5a0-4e67-8fe9-262d41670f71, Murgia-Esteve, X.(Xabier)|||/items/a7b1dc5e-17c6-4a09-aa59-b9b8ff42d0dd, Antón-Remírez, R. (Raúl)|||/items/d7aebae0-a4c3-40be-8584-d0d488c036f9
Tipo de recurso: artículo
Fecha de publicación:2017
País:España
Institución:Universidad de Navarra
Repositorio:Dadun. Depósito Académico Digital de la Universidad de Navarra
Idioma:inglés
OAI Identifier:oai:dadun.unav.edu:10171/68790
Acceso en línea:https://hdl.handle.net/10171/68790
Access Level:acceso abierto
Palabra clave:Respiratory-distsress-syndrome.
In-silico models.
Preterm infants.
Open label.
Deposition.
Ventilation.
Inhalation.
Therapy.
Descripción
Sumario:Surfactant aerosol delivery in conjunction with a noninvasive respiratory support holds the potential to treat neonatal respiratory distress syndrome in a safe manner. The objective of the present study was to gain knowledge in order to optimize the geometry of an intracorporeal inhalation catheter and improve surfactant aerosol delivery effectiveness in neonates. Initially, a mathematical model capable of predicting the aerosol flow generated by this inhalation catheter within a physical model of the neonatal trachea was implemented and validated. Subsequently, a numerical study was performed to analyze the effect of the aerosol liquid droplet size and mass flow rate on surfactant delivery and on the required aerosolization time period. Experimental validation of the mathematical model showed a close prediction of the air axial velocity at the distal end of the physical model, with an absolute error between 0.01 and 0.15 m/s. Furthermore, an admissible absolute error between 0.2 and 2 mm was attained in the prediction of the aerosol mean aerodynamic diameter and mass median aerodynamic diameter in this region. The numerical study highlighted the beneficial effects of generating an intracorporeal aerosol with a mass median aerodynamic diameter higher than 4 mm and a surfactant mass flow rate above 8.93 mg/s in order to obtain effective surfactant delivery in neonates with minimal airway manipulation.